Forwards IE Bulletin 79-26, Boron Loss from BWR Control Blades. Response Required
ML19253C133
Person / Time
Site: Humboldt Bay
Issue date: 11/20/1979
From: Engelken R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To: Crane P
PACIFIC GAS & ELECTRIC CO.
References
IEB-79-26, NUDOCS 7911300027
Download: ML19253C133 (1)


Text

o pn atog

+f o,,

UNITED STATES y

8 i' NUCLEAR REGULATOHY COMMISSION

,g r,i,f 1 C REGION V o,

g 1990 N. CALIFORNIA BOULEVARD e

SUITE 202, WALNUT CREEK PLAZA WALNUT CR E E K. CALIFORNI A 94LJ6 November 20, 1979 Docket No. 50-133 Pacific Gas and Electric Company 77 Beale Street San Francisco, California 94106 Attention: Mr. Philip A. Crane, Jr.

Assistant General Counsel Gentlemen:

The enclosed IE Bulletin No. 79-26 is forwarded to you for action. A written response is required.

If you desire additional information re-garding this matter, please contact this office.

Sincerely, n y d ilA ~

R. H. Engelken Director

Enclosures:

1.

IE Bulletin No. 79-26 2.

List of Recently Issued IE Bulletins cc w/ enclosures:

W. Barr, PG&E W. Raymond, PG&E E. Weeks, PG&E, Humboldt Bay 1443

?45 0 2+

7911300 4

UtlITED STATES SSIriS:

6820 flVCLEAR REGULATORY COMMISS10fl Accession tio.:

OFFICE OF It1SPECTI0tl Af4D EfiFORCEMEilT 7910250475 WASHIfiGT0;l, D.C.

20555 ilovember 20, 1979 IE Bulletin ilo. 79-26 BORON LOSS FROM BWR C0iTROL BLADES Description of Circumstances:

The General Electric Company (GE) has informed us of a failure mode for control blades which can cause a loss of boron poison material.

Hot cell examinations of both foreign and domestic blades have revealed cracks near the upper end of stainless steel tubing and loss of boron from the tubes.

The cracks and boron loss have so far been gnfined to locations in the poison tubes with more than 50 percent Boron-10 (B ) local depletion.

Observed crack sizes range from a quarter to a half inch in length and from one to two mils in width.

GE has postulated that the cracking is due to stress corrosion induced by solidification of boron carbide (B C) particles and swelling of the compacted g

B C as helium and lithium concentrdtions grow.

Once primary coolant penetrates thecladding(i.e.,thecrackinghasprogressedthroughthecladdingwallandthe helium-lithium pressures are sufficient to open the gack), boron is leached out of the tube at locations with more than 50 percent B local depletion (local depletion is considered to be twice the average depletion).

It was furtgr found with similar cracking but with less than 50 percent local depletion of B

, that leaching did not occur even though primary coolant had penetrated the cladding.

The cracking and boron loss shorten the design life of the control blade.

According to the GE criteria the end of design life is reached when the reactigty worth of the blade is reduced by 10 percent, which corresponds to 42 percent B depletion averaged over the top quarter of the control glade.

Because of the i

leaching mechanism, GE has reduced the allowance for B depletion averaged over the top quarter of the control blade from the 42 percent value to 34 percent.

The safety significance of boron loss is its impact on shutdown capability and scram reactivity. Although shutdown capability is demonstrated by shutdown margin tests after refueling, the calculated control blade worths used in the tests are based on the assumption that no boron loss has occurred.

Reduction in scram reactivity due to boron loss could increase the severity of Critical Power Ratio (CPR) reductions during the plant transients and could increase the consequences of control rod drop accidents.

Because the locations of limiting Average Planar LHGR (APLHGR) are monitoring is not affected by bor DUPLICATEDOCUMENTlkk