Notice of Violation from Insp on 790627-29
ML19250C460
Person / Time
Site: Oconee  
Issue date: 07/13/1979
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML19250C434 List:
References
50-269-79-17, 50-287-79-16, NUDOCS 7911260160
Download: ML19250C460 (1)


Text

.

APPENDIX A s

NOTICE OF VIOLATION Duke Power Company License No. DPR-55 Oconee Nuclear Station Unit 3 Based on the NRC inspection June 27-29, 1979, certain of your activities were apparently not conducted in full compliance with NRC requirements as indicated below. These items have been categorized as described in correspondence to you dated December 31, 1974.

As required by 10 CFR 50 Appendix "B" Criterion V, and as implemented by DPC Topical Report 1A Section 17.2.5 and Oconee Technical Specification Section 6.4.1, activitias affecting quality shall be prescribed by docu-mented instructions, procedures or drawings... and shall be accomplished in accordance with these instructions, procedures or drawings.

1.

DPC Oconee Procedure MP/0/A/3018/51 paragraph 11.2.5 requires that bolts with less than minimum thread engagement (3/8" for " diameter bolts) must be replaced.

Contrary to the above,

" diameter bolts for pipe supports 51A-H102 and 51A-H50G did not have minimum 3/8" thread engagement after repairs and were not replaced.

2.

Sketch H47G issued for repair of support 51A-0-1479E-H47G showed two base plates that were not welded together.

Contrary to the above, the two base plates were welded together.

This is an infraction.