ML19250A655

From kanterella
Jump to navigation Jump to search
Forwards IE Insp Repts 50-373/79-31 & 50-374/79-21 on 790821-22.No Noncompliance Noted
ML19250A655
Person / Time
Site: LaSalle  Constellation icon.png
Issue date: 09/11/1979
From: Fiorelli G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Brian Lee
COMMONWEALTH EDISON CO.
Shared Package
ML19250A656 List:
References
NUDOCS 7910240154
Download: ML19250A655 (2)


See also: IR 05000373/1979031

Text

7i L

  • atcoq'o

UNITED STATES

e

!'

'g

NUCLEAR REGULATORY COMMISSION

'

'

, , ,

..
    • f c

REGION 111

8

799 ROOSEVELT RoAO

o

E

GLEN ELLYN, ILLINolS 60137

Okk ] 1 }9ye

o

-

  • s..e

Docket No. 50-373

Docket No. 50-374

.

Commonwealth Edison Company

ATTN:

Mr. Byron Lee, Jr.

Vice President

Post Office Box 767

Chicago, IL 60690

Gentlemen:

This refers to the inspection conducted by Mr. J. H. Neisler of this

office on August 21 and 22, 1979, of activities at La Salle County

Station, Units 1 and 2, authorized by h3C Construction Permit No. CPPR-99

and No. CPPR-100 and to the discussion of our findings with Mr. L. J. Burke

and others of your staff at the conclusion of the inspection.

The enclosed copy of our inspection report identifies areas examined

during the inspection. Within these areas, the inspection consisted of a

selective examinztion of procedures and representative records,

observations, and interviews with personnel.

No items of noncompliance with NRC requirements were identified during

the course of this inspection.

In accordance with Section 2.790 of the PRC's " Rules of Practice," Part

2, Title 10, Code of Federal Regulations, a copy of this letter and the

enclosed inspection report will be placed in the NRC's Public Document

Room, except as follows.

If this report contains information that you or

your contractors believe to be proprietary, you must apply in writing to

this office, within twenty days of your receipt of this letter, to withhold

such information from public disclosure. The application must include a

full statement of t'e reasons for which the information is considered

a

proprietary, and should be prepare.J so that proprietary information

identified in the application is contained in an enclosure to the

application.

.

1202

321

15 4

1024o

4 ,;

'

SEP 11 1979

.

Commonwealth Edison Company

-2-

.

We will gladly discuss any questions you have concerning this

inspection.

Sincerely,

[p

~

Gaston Fiorel?.i, Chief

Peactor Construction and

Engineering Support Branch

Enclosure:

IE !nspection

Reports No. 50-373/79-31

and No. 50-374/79-21

cc w/ encl:

Mr. L. J. Burxe, Site

Project Superintendent

Mr. T. E. Quaka, Quality

Assurance Supervisor

Mr. R. H. Holyoak, Station

Superintendent

Central Files

Reproduction Unit h3C 20b

PDR

Local PDR

NSIC

TIC

Mr. Dean Hansell, Office of

Assistant Attorney General

.

1202

322