Text

.

.

[go acog'o,

UNITED STATES

E'

.,q/ *' 7.

NUCLEAR REGULATORY COMMISSION

.

E

REGION 11

i ,h jf. f

o,

Q

101 MARIETT A sT., N W , sulTE 3100

ATL ANT A, GEORGI A 30303

'

'Ns

j'

'.,

  • ..*

In Reply Refer To:

JUN ] 51979

RII:GLT

50-348/79-21

Alabama Power Company

t.ttn:

F. L. Clayton, Jr.

Senior Vice President

Post Office Box 2641

Birmingham, Alabama 35291

Gentlemen:

This refers to the inspection conducted by G. L. Troup of this office on

May 21-25, 1979 of activities authorized by h7C License No. NPF-2 for

the Farley facility, Unit 1, and to th- discussion of our findings held

with W. G. Hairston III at the conclusion of the inspection.

Areas examined during the inspection and our findings are discussed in

the enclosed inspection report. Within these areas, the inspection

consisted of selective examinations of procedures and representative

records, interviews with personnel, and observations by the inspectors.

During the inspection, it was found that certain activities under your

license appear to be in noncompliance with h7C requirements. These

items and references to pertinent requirements are listed in the Notice

of Violation enclosed herewith as Appendix A.

This notice is sent to

you pursuant to the provisions of Section 2.201 of the NRC's " Rules of

Practice", Part 2, Title 10, Code of Federal Regulations.

Section 2.201

requires you to submit to this office, within 20 days of your receipt of

this notice, a written statement or explanation in reply including:

(1)

corrective steps which have been taken by you, and the results achieved;

(2) corrective steps which wl:1 be taken to avoid further noncompliance;

.

and (3) the date when full compliance will be achieved.

"05.WS

In accordance with Section 2.790 of the NRC's " Rules of Practice,"

Part 2, Title 10, Code of Federal Regulations, a copy of thi;. letter and

the enclosed inspection report will be placed in the NRC's Public Document

Room.

If this report contains any information that you (or your contractor)

believe to be proprietary, it is necessary that you make a written

application within 20 days to this office to withhold such information

from public disclosure. Any such application must include a full statement

of the reasons on the basis of which it is claimed that the information

is proprietary, and should be prepared so that proprietary information

identified in the application is contained in a separate part of the

document.

If we do not hear froc you in this regard within the specified

period, the report will be placed in the Public Document Room.

7908160Vfd

. _ _ _ _ _ . _

JUN 151979

.

Alabama Power Company

-2-

Should you have any questions concerning this letter, we will be glad to

'

discuss them with you.

Sincerely,

h

W kbt

J. T. Sutherland, Chief

Fuel Facility and Materials

Safety Branch

Enclosures:

1.

Appendix A, Notice of Violation

2.

Inspection Report No. 50-348/79-21

cc w/ enclosures:

A. R. Barton

Executive Vice President

Post Office Box 2641

Birmingham, Alabama 35291

H. O. Thrash

Manager-Nuclear Generation

Post Office Box 2641

Birmingham, Alzbama 35291

1

C. Biddinger, Jr.

Manager-Corporate Quality Assurance

Post Office Box 2641

Birmingham, Alabama 35291

W. G. Hairston III

Plant Manager

Drawer 470

Ashford, Alabama 36312

R. E. Hollands, Jr.

.. . . 3 h3 b' .)

QA Supervisor

  1. E}

Post Office Box U

Ashford, Alabama 36312

.