MAY 3 01979 APPENDIX A NOTICE OF VIOLATION i:_stinghouse Electric Corporation License No. SNM-1107 Based on the NRC inspection May 8-11, 1979, certain of your activities were apparently not conducted in full compliance with NRC requirements as indicated below. These items have been categorized as described in correspondence to you dated December 31, 1974.

As required by License Condition No. 9 incorporating the license application subsection 3.1.2, " Position Responsibilities," states, in part, that a line mana2er will assure that all operations are carried out in accordance with the schedules, processing procedures, nuclear criticality safety and radia-tion protection limits, and other instructions supplied by highet management.

Contrary to the above, line management permitted operations to be performed which were not in accordance with the posted instructions materials (SNM) in the QC Lab storage cabinet.

The posted instructions require, among other things, that the storage shelves be separated by at lear.t 16 inches.

In contrast the shelves in the storage cabinet were separated by 15 inches.

7 908150Got (c.,

(oc

,n

.vs

,