05000366/LER-1979-052-03, /03L-0 on 790612:reactor Cooldown Max Rate of 100 F/H Was Exceeded.Caused by Manually Starting HPCI During Scram,Resulting in Rapid Pressure.Personnel Admonished

From kanterella
(Redirected from ML19248C840)
Jump to navigation Jump to search
/03L-0 on 790612:reactor Cooldown Max Rate of 100 F/H Was Exceeded.Caused by Manually Starting HPCI During Scram,Resulting in Rapid Pressure.Personnel Admonished
ML19248C840
Person / Time
Site: Hatch 
Issue date: 06/27/1979
From: Baxley S
GEORGIA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19248C838 List:
References
LER-79-052-03L, LER-79-52-3L, NUDOCS 7907050376
Download: ML19248C840 (2)


LER-1979-052, /03L-0 on 790612:reactor Cooldown Max Rate of 100 F/H Was Exceeded.Caused by Manually Starting HPCI During Scram,Resulting in Rapid Pressure.Personnel Admonished
Event date:
Report date:
3661979052R03 - NRC Website

text