DRC-POR

,,(p nauq[g UNITED STATES NUCLEAR REGULATORY COMMISSION y

g

E WASHINGTO N, D. C. 20555

~%,

/

JUL g9979 NOTE T0:

A. Schwencer, Chief, Operating Reactors Branch #1, D0R D. Ziemann, Chief, Operating Reactors Branch #2, D0R R. Reid, Chief, Operating Reactors Branch #4, 00R FROM:

G. Lainas, Chief, Plant Systems Branch, 00R

SUBJECT:

STEAM GENERATOR WATER LEVEL INSTRUMENTATION Attached is a memorandum from G. Lainas to D. Eisenhut dated July 9,1979 regarding the effect of high environmental temperature on steam generator water level instrumentation.

As stated in the memorandum, I&E plans to take action to ensure that affected licensees of Westinghouse operating reactors take the appropriate actions.

Further, I&E is also developin0 a Bulletin to pursue this matter generically for all other reactor designs.

The memorandum also advised that this item be the subject of a Board Notifi-cation.

/

n,-

pv G. LhMas, Chief Plant Systems Branch Division of Operating Reactors

Contact:

M. Chiramal, X28077 Enclosure :

As stated cc w/ enclosure:

D. Eisenhut D. Tondi W. Gammill E. Butcher B. Grimes M. Chiramal G. Lainas L. Nichols 62f)IUf5

'l/

9080200 %