The enclosed IE Bulletin No. 79-15 is forwarded to you for action.
A written response is required.
If you desire additional information regarding this matter, please contact this office.
Sincerely, dB
- James G. Keppler Director
Enclosures:
1.
Listing of IE Bulletins Issued in Last 12 Months cc w/ encl:
Central Files Director, NRR/DPM Director, NRR/ DOR PDR Local PDR NSIC TIC Ronald Callen, Michigan Public Service Commission Eugene B. Thomas, Jr.,
Atto rney m
O
/
bd b'
7907310334
U.S. NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT REGION III July 11, 1979 IE Bulletin No. 79-15 DEEP DRAFT PUMP DEFICIENCIES
~
Description of Circumstances:
On October 20, 1978, Co==onwealth Edison Company reported that manufacturing deficiencies had been identified in new high pressure core spray, low pressure core spray, and residual heat removal pu=ps manufactured by Ingersoll-Rand (I-R)
Company, Cameron Pu=p Division.
Each of these pu ps is a vertical turbine pu=p with i=pellers located in bowls in a su=p or a self contained barrel.
The motor (pri=e mover) is located at the highest pu=p elevation to take into account maximum flooding at the site
.or space consideratier:s. The suction is at the lower end of the pu=p while the discharge head is just below the driver. Bearings supporting the vertical shaft seg=ents (usually 5 to 10 seg=ents) are either self lubricated, force fed (lubricated by fluid being pu= ped), or oil lubricated and maintained within their own isolated system. These pumps are designated as " Deep Draf t".
Figures 1&2 show typical outlines of such pumps.
The internal deficiencies, identified through dimensional and visual inspections were as follows:
Lov Pressure Core Spray Pu=ps (I-R Model No. 29APKD-5) (Date of Manufacture -
Feburary 1973)
Loose impeller bolts and bolts improperly staked Loose key - keyway fit Excessive runout on pu=p shaf t Bearing showed wear Bearing clearance exceeded recommended tolerance Ccupling thread galled Wear ring clearance out-of-specification Impeller-to-shaft clearance out of specification s
. gp Cracks found in second-and-third-stage i=pellers U i UMO Stuffing box bushings vers severely galled High Pressure Core Spray Pu=ps (I-R Model No. 12X200) (Date of Manufacture -
September 1972)
Bearing clearance exceeded reco= mended tole:~,
.a
~-
i Wear ring clearance out-of-specification DUPLICATE DOCUMENT Bearings showed wear