Forwards IE Insp Repts 50-445/79-14 & 50-446/79-14 on 790515-18.No Noncompliance Noted
ML19246C498
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 06/01/1979
From: Seidle W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Gary R
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
Shared Package
ML19246C499 List:
References
NUDOCS 7907250498
Download: ML19246C498 (2)


See also: IR 05000445/1979014

Text

%q'g

UNITED STATES

[ '% s .g h

NUCLEA R REGULATORY COMMISSION

M " 8/. s

REGION IV

3 TIhf /' [

o,

611 P. van PLAZA DRIVE, SUITE 1000

\\ . .' ./ [

ARLINGTON, TE X AS 70012 / - --

..

June 1, 1979

In Raply Refer To:

RIV

Docket No. 50-445/Rpt. 79-14

50-446/Rpt. 79-14

Texas Utilities Generating Company

ATTN : Mr. R. J. Gary, Executive Vice

President and General Manager

2001 Bryan Tower

Dallas, Texas

75201

Gentlemen:

This refers to the inspection conducted by Mr. L. E. Martin of our staff during

the period May 15-18, 1979, of activities authorized by NRC Construction Permits

No. CPPR-126 and 127 for the Comanche Peak facility, Units fio.1 and 2, and to

the discussion of our findings with Mr. R. G. Tolson and other members of your

staff at the conicusion of the inspection.

Areas examined during the inspection and our findings are discussed in the

enclosed inspection report. Within these areas, tne inspection consisted of

selective examination of procedures and representative records, interviews

with personnel, and observatinns by the inspector.

Within the scope of the inspection, no items of rioncompliance were identified.

In eccordance with Section 2.790 of the NRC's " Rules of Practice," Part 2,

Title 10, Code of Federal Regulations, a copy of this letter and the enclosed

imosction report will be placed in the NRC's Fublic Document Room.

If the

repo." contains any information that you believe to be proprietary, it is

necessa. / that you submit a written application to this office, within 20 days

of the det of this letter, requesting that such information be withheld from

oublic disclosure. The application must include a full statement of the reasois

why it is claimed that the information is proprietary. The application should

be prepared so that any proprietary information identified is contained in an

enclosure to the application, since the application without the enclosure will

also be placed in the Public Document Room.

If we do not hear from you in this

regard with4 1 the raecified period, the report will be placed in the Public

Document Room.

.-i

)

700725047%

.

.(

Texas Utilities Generaing Company

-2-

June 1, 1979

, , _ -

Should you have any questions concerning this inspection, we will be pleased to

discuss them with you.

Sincerely,

-

/

l'-

v

,

jf. I / dce

-

W. C. Seid q, Chief

Reactor Construction and

Engineering Support Branch

Enclosure:

IE Inspection Report No. 53-445/79-14

50-446/79-14

cc: w/ enclosure

Texas Utilities Generating Company

A TTN : Mr. H. C. Schmidt, Project Manager

2001 Bryan Tower

Dallas, Texas

75201

-T