Forwards IE Circular 79-10, Pipefittings Mfg from Unacceptable Matl. No Action Required
ML19246A662
Person / Time
Site: Trojan File:Portland General Electric icon.png
Issue date: 06/26/1979
From: Engelken R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To: Goodwin C
PORTLAND GENERAL ELECTRIC CO.
References
NUDOCS 7907060218
Download: ML19246A662 (1)


Text

pn "Huq'o, fk UNITED STATES i

e

c,,d; "., ([' (,

['}td '

. I:

NUCLEAR REGULATORY COMMISSION REGION V o, -?

.h

[

1990 N. CALIFORNIA BOULEVARD

  • d' SUITE 202, WALNUT CREEK PLAZA kk 'f l

C.

s e,,,e WALNU r CREEK, CALIF ORNI A 94596 June 26,1979 Docket tio. 50-344 Portland General Electric Company 121 S. W. Salmon Street Portland, Oregon 97204 Attention:

Mr. Charles Goodwin, Jr.

Assistant Vice President Gentlemen:

This Circular is provided as an eaHy notification of a possibly significant illd tter.

It is expected that recipients will review the information for possible applicability to their facilities.

?!o specific action or response is requested at this time.

If further tiRC evaluations so indicate, an IE Bulletin will be issued to recommend or r' quest specific licensee actions.

If you have questiens regarding this matter, please contact the Director of the appropriate NRC Regional Office.

Sincerely, n

%--

  • C ' l v

)

n_

R. H. Engelken Director

Enclosures:

1.

IE Circular No. 79-10 2.

List of IE Circulars Issued in Last 12 Months cc w/ enclosures:

B. Withers, PGE F. Gaidos, PGE 298. 242 79079 4

UflITED STATES fiUCLEAR REGULATORY COBlISSION OFFICE OF IfiSPECTION AND EilFORCEf1EllT WASHINGTON, D.C.

20555 June 26, 1979 IE Circular fio. 79-10 (7906200171}

PIPEFITTIt:GS fiANUFACTURED FROM UNACCEPTABLE f1ATERIAL Description of Circumstancr Liberty Equipment and Supply Company of Kennewick, Washington and Tube Turns Division, Chemetron Corporation of Louisville, Kentucky reported on April 4 and 12, 1979, respectively, that potentially defective pipe fittings were manufactured from material with a high carbon content beyond the range allowed by ASTM A-234 WPB. These high carbon content fittings may crack when welded.

Tube Turns received 3.500 OD x.250W pipe fron U. S. Steel - Lorain -

identified as U. S. Steel Heat flo. fl570028. A total of 28,153 feet was received and identified by Tube Turns as Lot W6719.

U. S. Steel has not been able to determine the exact number of lengths of pipe of incorrect chemistry, but indicated it could be at least four lengths.

From this pipe, 4" - 90 degrees and 45 degrees

.237 wall elbows and 2"

.237 wall straight tees, ASTM A-234 WPB, were produced by Tube Turns.

Fach length of pipe is twenty feet and makes from 20 to 30 " ttings.

Approximately 27,000 fittings were produced and each is identified by Tube Turns' Lot !!o. W6719.

Shipment of these fittings started in March of 1978, and it is estimated all were shipped before the end of 1978.

On fiay 10, 1979, the Tube Turns Division reported to the NRC that 4" elbows, Lot W6719, have been provided to the nuclear pcwer olants listed below U.S.

Steel has tested about one hundred and fifty (150) loose and installed fittings at the seven sites noted by an asterisk.

  • Grand Gulf
  • Zimmer
  • Phipps Bend
  • Uaterford III
  • Brown's Ferry flidland Limerick Shoreham
  • LaSalle Sequoyah
  • Brunswick Hartsville Bellefonte On June 1,1979, the Tube Turns Divisica reported to the flRC via telephone that of the 160 fittings tested at fluclear Power Plants, three (3) pieces were found to have a high carbon conter.t and were replaced.

All construction perait holders are advised to conduct a review of their pipefitting receiving documents for the period from " arch 1978 to January 1979 and deternin if fittings nanufactured by the Tube Turn Division can be identified as Nbe Turn Lot W6719.

If shipment of the defective raterial lot were received, aporopriate corrective action should be initiated, tio written response to this circular is required.

If you require additional infornation regarding this subject, contact the Director of the appropci9ta f1RC Regional Office.

298 20 7907020I7I bc

IE ' Circular No. 79-10 Enclosure Page 1 of 2 June 26, 1979 LISTIriG OF IC CIRCULARS ISSUED Ili LAST TWELVE PoliTHS Circular Subject Date Issued To of Issue rio.

78-12 HPCI Turbine Control 6/30/73 All Holders of Valve Lift Rod Bending B',lR OLs or cps for plants with HPCI Terry Turbine 78-13 Inoperability of Multiple 7/10/73 All Holc.rs of Service 'later Pumps Reactor OLs and cps except for plants located in: AL, AK, CA, FL, GA, LA, MS, SC 78-14 HPCI Turbine Reversing 7/12/78 All Holders of BWR Chamber Hold Dcwn Boltirig OLs or cps for plants with a HPCI Terry Turbine excepting Duane Arnold and Monticello 78-15 Checkvalves Fail to 7/20/73 All Holders of Close In Vertical Reactor OLs or cps Position 78-16 Limitorque Val ve 7/26/7s All Holders of Actuators Reactor OLs or cps 78-17 Inadequate Guard Training /

10/13/70 All Holders of Qualification and Falsified and applicants Training Records for Reactor OLs 78-18 UL Fire Test 11/6/78 All Holders of Reactor OLs or cps 78-19 Manual Override (Bypass) 12/28/78 All Holders of of Safety Actuation Signals cps

~..

IE' Circular No. 79-10 Enclosure June 26, 1979 Page 2 of 2 LISTING OF IE CIRCULARS ISSUED IN LAST TWELVE MONTHS Circular Subject Date of Issued to No.

Issue 79-01 Administration of 1/12/79 All Holders of Unauthorized Byproduct Licensees except Material to Humans Teletherapy Medical Licensees and each Radiopharmaceutical Suppliers 79-02 Failure of 120 Volt Vital 2/16/79 All Holders of AC Power Supplies Reactor OLs and cps 79-03 Inadequate Guard Training-2/23/79 All Holders of Qualification and Falsified and applicants Training Pecords for Special Nuclear Material Licenses in Safeguards Group I 79-C4 toose mucking Nut On 3/1C/79 All Holders of Limitorque Valve Reactor OLs or cps Operators 79-05 Moisture Leakage In 3/20/79 All Holders of Stranded Wire Conductors Reactor OLs or cps 79-00 Failure to Use Syringe 4/19/79 All Holders of and Battle Shields in Medical Licensees Nuclear Medicine except teletherapy licensees 79-07 Unexpected Speed Increase 5/2/79 All Holders of of Reactor Recirculation EWR OL's or CP's MG Set Resulted in Reactor Power Increase 79-03 Attempted Extortion - Low 5/18/79 All Fuel Facilities Enriched Uranium Licensed by HRC 79-09 Occurrences of Split or 6/22/79 All Materials Punctured Regulator Diapnragos Priority I, Fuel In Certain Self Contained Cycle and Operating Breathing Apparatus Reactor Licensees 29O