ML19242A149
| ML19242A149 | |
| Person / Time | |
|---|---|
| Site: | Grand Gulf |
| Issue date: | 07/11/1979 |
| From: | James O'Reilly NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| To: | Stampley N MISSISSIPPI POWER & LIGHT CO. |
| References | |
| NUDOCS 7907310384 | |
| Download: ML19242A149 (2) | |
Text
, -
I l
4e f
[s** %q'o UNITED STATES l'
- c. cf
'n NUCLEAR REGULATORY COMMISSION
- 72/
E REGION 11 101.A AR tET T A ST, N W, SL'IT E 3100 ig [f o,
AT L ANT A, GEoRCI A 30303 6
'N.-
JUL 1 ' 1979 In Reply Refer To:
RII:JP0 50-416 50-417 Mississippi Power and Light Company AITN:
N. L. Stampley Vice President of Production P. O. Box 1640 Jackson, MS 39205 Gentlemen:
The enclosed Bulletin No. 79-15 is forwarded to you for action. A written response is required.
If you desire additional information regarding this matter, please contact this office.
Sincerely,
. 3-_
,[
k James P. O'Reilly Director
Enclosures:
1.
lE Bulletin No. 79-15 2.
Listing of IE Bulletins Issued in Last 12 Months 7907310384
{
g
liississippi Power and Light Company cc w/ encl:
C. K. McCoy Plant Manager Post Office Box 756 39150 Po'rt Gibson, Mississippi e
O e
9
' ?
?
_)
UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.
20555 July 11, 1979 IE Bulletin No. 79-15 l
DEEP DRAFI PUMP DEFICIENCIES Description of Circumstances:
Com=onwealth Edison Company reported that manufacturing On October 20, 1978, deficiencies had been identified in new high pressure core spray, low pressure core spray, and residual heat re= oval pumps manufactured by Intersoll-Rand (I-R)
Company, Caceron Pu=p Division.
Each of these pumps is a vertical turbine pump with impellers located in bowls The motor (prime mover) is located at in a su=p or a self contained barrel.
the highest pu=p elevation to take into account maximu= flooding at the site The auction is at the lover end of the pu=p while or space considerations.
Bearings supporting the vertical the discharge head is just below the driver.
shaft segments (usually 5 to 10 segments) are either self lubricated, force fed (lubricated by fluid being pu= ped), or oil lubricated and maintained within These pu=pa are designated as " Deep Draft".
Figures their own isolated syste=.
1&2 show typical outlines of such pu=ps.
identified through dimensional and visual inspections The internal deficiencies, were as follows:
29APKD-5) (Date of Manuf acture -
low Pressure Core Spray Pu=ps (I-R Model No.
Feburary 1973)
Loose impeller bolts and bolts improperly staked Loose key - keyvay fit Excessive runout on rump shaft Bearing showed wear Bearing clearance exceeded recocnended tolerance Coupling thread galled Wear ring clearance out-of-specification Impeller-to-ahaft clearance out of specification Cracks found in second-and-p d-stage impellers Stuffing box bushings were JDUpt T
I" High Pressure Core Spray Pu=p Entire d cument e
Septe=ber 1972) into 4
system under Ous1Y ente Bearing clearance exceeder ANO Vear ring clearance out-o y
Bearings showed wear 30, 0f Pages Chm
,o mc
'a t
,