ML19225B073

From kanterella
Jump to navigation Jump to search
LER 79-057/03L-0 on 790624:while Performing Test for Svc Water Operability,Valve Closed & Would Not Reopen Electrically.Caused by Torque Switch Corroding to Switch Shaft.Torque Switch Repaired
ML19225B073
Person / Time
Site: Hatch Southern Nuclear icon.png
Issue date: 07/10/1979
From: Dayley C
GEORGIA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19225B072 List:
References
LER-79-057-03L, LER-79-57-3L, NUDOCS 7907230482
Download: ML19225B073 (2)


Text

.

U. S. NUCL E An RC GUL AT ony ctv.'.a.1is,ica F CH?.. KG 7)

LICENSEE EVENT REPORT l (PLE ASE PRINT Ca TYPE ALL nECUIHED INFOnM,itt Ni ccNract occa l l l l 1 il i C I A l E l ! l H i ,v 2 !(?! 0 l 0 l - l 0 l 0 l 010 ! O j - l010 v l'Tl 4 l1 l In u.al1w11 e ai l l(?!

a a

u. u ?. <. - < a .+ si

.s ., L - _ . , a

r i t l:',[,"c[ l L !@ l 0 1 S l 0 1 0 1 0 1 3 1 6 I 6o '@ o 0 13 assr 12 I? I7lo a@ 01711le17 oArE is avestoArE lo ol@

a w u cw .<. e Ew.T oEscaianca no poca AcLt c AsEcusNcts @

i2 l While cerfor. ina u1P-2-3183. Service '.la ter val ve ocerability, 2P41-F315 waLclosed butt

~

[

,3 lwould not reccen electrically. The Reactor Bida. trinced on high condenser cressure 1

,a j due to the lack of cooling. The drvwell internal cressure increased to > .75 PSIG.

_j 3s  ; Cue to the lack of cooling to the drywell ventilation from Re3ctor Bido. chillors

,4 } [ Per Tech. Scecs. 3.6.1.6 crimary containment internal cressure shall not exceed 0.U uealth or Safety. l 4, [csig. There were no ef#ects ucon Public I

80 3is i f CCYP vatvE 3 9 CAUSE CAcSE sua;::E S f 3T!'.1 . COVpCNENT COOE Sys:::E COCE C00E SL9C00E 131 [W I Aj @ l E j@ l A l@ l'l I A l L l V 10 ! ? l@ l A l@ l NZ j @

13 id 19 8 9 'O T3 12 REFCAT REV'S!ON CCCU A R E *.CE

. SEOUENTI AL COOi TvPE N O, A EPORT N O.

g = qg _EVENTYEAh l 0l 5l 7l26 l/l l013l lL l ll [0_I om 7c a l21- 7i 9i O =(E l-l 27 28 23 ~ 30 Ji 32 22 22 24 C 0 Y ' O '* E i

ACWYENT N P Al* ? E FO't?

Sra f 0 0.*.N Sur uEa eeune;-u A CT ;C N FUTy E E::ECT scuas x AT'a su vi TT E : ac rm. AT:N 1u A'gla Zi@

evatisT la ZI@

VET ca l Zl@ a,10 101 Ol l lu Yl@ lNl@

42 p

o

@ lLl2l0iOl@

u u

.6 ao i

cAuss csscwrics asc cease:Ti.s AcTicNs @

im,  ; The limit torque switch, SMB-000, for valve 2P41-F315A had corncdec to the switch shaf; j

and caused the switch to hang af ter the valve was closed not allcwing the valve to i coen. Recpeneo valve by hand, restarted Reactor Sldg. chiller, recovered dry ell pres:

to less than .75 PSIG within time allowable per Tech. Specs. 3.5.1.6 action state ~nt !

, ,, , and had Trocue switch repaired per M.R. 2-79-3181 and furetional test of valve cont'd D d ) e UE TwCD OF 3-Fa;t; Tv "

0 5CC'. E A V DISCOVERv 0ESCP 7 TION A %7CWER OTHER ST A T'JS j O r e.

NA l lA!@l Onerc or Otervatien i 15a {, E }@ Ol 01 C}@l a n u 45 46 sa o

A:t vtTv C O N * ; *. T LOC ATION CF aELE AS E AFLEa5;D C'DELEaiE AVCW'.TCFACTWify I l l PA

' 'A u

' Gi>l l Z l ~: ol Z G.l  %, u 4s

.Ense , sit o .cs - Es

?vaE O E 3;nt P Ti;N 39 - I NL+mt a , - r, e m NA

' 5 I > l l 0 10 10 9~ 1 Z -1912 7't/ VUd N a > ii  :

eus T.a.E t ,W a Ei

= l

, , 9y p '"'"=} -

u

,i g 7- m." O .

79072 3 l I1 'l c, a j.n "

! M9 22

.,' ,  ; wc - .t

, o I '

} l l I l  ! I f

]

,  ! 'l $ ,a , , ,

' ' ' ^1 C. ,* + P ssraf g; e (C . -

Juif 12, 1979 F232 2 (cont'd) Cause Description and Corrc-ctive Action 2P41-F315A was satisfactcry. Reference previcus LER's 2-78-33, ? . and 2-79-54 , f 9 i /}}