ML19225A382

From kanterella
Jump to navigation Jump to search
Forwards Suppl IE Bulletin 79-01A, Environ Qualification of Class IE Equipment (Deficiencies in Environ Qualification of Asco Solenoid Valves). Action Required
ML19225A382
Person / Time
Site: Sterling
Issue date: 06/06/1979
From: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Arthur J
ROCHESTER GAS & ELECTRIC CORP.
References
NUDOCS 7907190113
Download: ML19225A382 (1)


Text

.s p *"T=u (k

o, UNITED STATES S ?, c c */ h NUCLEAR REGULATORY COMMISSION 3-2 REGION I bp',[

0, 631 PARK AVENUE

  • d' KING OF PRUSSIA, PENNSY LVANI A 19406 June 6, 1979 Docket No. 50-485 Rochester Gas & Electric Corporation ATTN:

Mr. J. E. Arthur Chief Engineer 89 East Avenue Rochester, NY 14649 Gentlemen:

Enclosed is supplement IE Bulletin 79-01A.

It requires action by you with regard to power reactor facility (ies) with an operating license except for the 11 SEP (Systematic Evaluation Program) plants which are listed in Enclosure 3.

This Bulletin is also being sent for information to the 11 SEP plants and all power reactor facilities with a construction permit.

No action or written response is required for these two categories of facilities.

Should you have questions regarding this Bulletin or the actions required of you, please contact this office.

Sincerely,

/Y 7

tWo+

_a ey:e rier

~

Director

Enclosures:

1.

IE Sulletin No. 79-01 A 2.

List of IE Bulletins Issued in Last Twelve Months 3.

List of SEP Plants (11) cc w/encls:

C. R. Anderson, Manager, QA Lex K. Larson, Esquire N. A. Petrick, Executive Director, SNUPPS Gerald Charnoff, Esquire

!) N b N ']

790719

ENCLOSURE 1 UNITED STATES dGCLEAR REGULATORY COMMISSION Wi SHINGTON, D.C.

20555 IE Bulletin No. 79-01 A Date: June 6, 1979 Page 1 of 3 SUPPLEMENT NO.79-01A TO IE BULLETIN 79 ENVIRONMENTAL QUALIFICATION OF CLASS 1E EQUIPMENT (DEFICIENCIES IN THE ENVIRONMENTAL QUALIFICATION OF ASCO S0LEN0ID VALVES)

Description of Circumstances:

Recently, a noncompliance report under 10 CFR Part 21 was received by the NRC from the Henry Pratt Company, manufacturer of butterfly valves which are installed in the primary containment at the Three Mile Island Unit 2 Nuclear Station.

These butterfly valves are used for purge and exhaust purposes and are required to. operate during accident conditions.

The report discusses the use of an unqualified solenoid valve for a safety-related valve function which requires operation under accident conditions.

The solenoid valve in question is Catalogue No. HT-8331A45, manufactured by the Automatic Switch Company (ASCO) of Florham Park, New Jersey.

This pilot valve is used to pilot control the pneumatic valve actuators which are installed on the containment ventilation butterfly valves at this facility.

The deficiency in these solenoid valves identified in the Part 21 Report concerns the parts made of acetal plastic material.

The acetal disc holder assembly and bottom plug in the pilot valve assembly are stated by ASCO to have a maximum service limit of 400,000 Rad integrated dosage and 200 degrees F temperature.

According to ASCO, exposure of these acetal plastic parts to specified maximum environmental conditions may render the solenoid pilot valve inoperable which would cause the associated butterfly valve to malfunction.

Further investigation at ASCO by the NRC staff has revealed that the valve seals in most ASCO solenoid valves contain Buna "N" elastomer material, which reportedly has a maximum service limit of 7,000,000 Rad integrated dosage and 180 degrees F temperature.

The investigation further revealed that ASCO has available a line of qualified solenoid operated pilot valves (ASCO Catalogue No. NP-1) which have no plastic parts, utilize ethylene propylene or viton elastomers and have a continuously energized operating life of four years, under normal embient conditions up to 140 degrees F.

According to the manufacturer, at the end of this period, the coil, manual operator (optional feature) and all resilient parts must be replaced.

These preventive maintenance instructions are specified in the installation and instruction bulletins which are provided to the purchaser with each shipment of solenoid valves.

The final items of concern identified during this investigation deals with the application of Class "A", "B", or "F", solenoid coils which are exposed to an accident environment.

In this regard, ASCO representatives stated that the 3)b

$b 290'2020173

IE Bulletin No. 79-Ol A Date: June 6, 1979 Page 2 or 3 high temperature coils identified as Class "HT" or "HB" are the only coils con-sidered suitable for service under accident conditions; whereas, Class "A", "B",

and "F" coils are not.

With respect to the corrective measures to be taken to resolve the above concerns, ASCO recommends the following:

1.

The parts of the solenoid valve made of acetal plastic material should be replaced with similar parts made of metal which can be provided by ASCO.

2.

The valve seals and gaskets which are made of Buna "N" material should be replaced with either ethylene propylene or viton elastomers, c nsidered by ASCO as suitable for the service intended.

3.

Review and determine that the coils of the solenoid valves inssalled inside containment are Class "HT" or "HB" as required for high te:aperature environmental conditions.

4.

Review and determine that the solenoid enclosures installed insice contain-ment have at least a NEMA 4 enclosure rating.

5.

Establish a preventive maintenance program to assure replacement of those valve parts identified above in the time period recommended in the appro-priate ASCO valve bulletin.

6.

ASCO also stated that all unqualified solenoid valves inside containment be retrofitted to qualified ASCO No. NP 1 valves in lieu of the above.

7.

Questions from licensees to ASCO concerning corrective measures should reference both catalogue and serial numbers of each valve in question.

These numbers are stamped on the metal nameplate on each solenoid valve.

Action to be aken by Licensees of all Power Reactor Facilities (except those 11 SEP Plants listed on Enclosure 3) with an Operating License:

1.

Determine whether or not ASCO solenoid valves are used or planned for use in safety-related systems at your facility (ies).

2.

If such valves are used or planned for use, identify the safety system involved and determine that:

(a) valves which could be subjected to a LO:A environment are qualified to that environment.

Specifically that no parts made of acetal plastic or Buna "N" materials or Class "A", "B",

or "F" solenoid coils are used in such valves; (b) a preventive main-tenance program is being conducted such that the solenoid coil, the manual operator (if applicable), and the resilient parts of the valve are being replaced in accordance with the time period established by the manufacturer and documented as the qualified life of the assembled component.

,n, bi' ie.

IE Bulletin No. 79-Ol A Date: June 6, 1979 Page 3 of 3 3.

All holders of operating licenses of power reactor facilities are obligated to meet the review and reporting requirements established in previously issued IE Bulletin 79-01, regarding environmental qualifica-tion of electrical equipment installed in their plants.

No additional written response to this Supplement IE Bulletin is required other than those responses described above.

NRC inspectors will continue to monitor the licensees' progress in completing the requested action described above. If additional information is required, contact the Director of the appropriate NRC Regional Office.

Approved by GAO, B180225 (R0072); clearance expires 7/31/80.

Approval was given under a blanket clearance specifically for identified generic problems.

  • O ~)

7 ' {]

3 JJ l l t.-

IE Bulletin Nc.79-01A Date:

June 6, 1979 Page 1 of 5 ENCLOSURE 2 LISTING 0F IE BULLETINS ISSUED IN Li.3T TWELVE MONTHS Bulletin Subject Date Issued Issued To No.

78-07 Protection afforded 6/12/78 All Power Reactor by Air-Lirie Respirators Facilities with an and Supplied-Air Hoods OL, all class E and F Research Reactors with an OL, all Fuel Cycle Facilities with an OL, and all Priority I Material Licensees 78-08 Radiation Levels from 6/12/78 All Power, Test and Fuel Element Transfer Research Reactor Tubes cacilities with an OL having Fuel Element Transfer Tubes 78-09 BWR Drywell Leakage 6/14/78 All BWR Power Paths Associated with Reactor Facil Inadequate Drywell with an OL (for action)

Closures or CP (for information) 78-10 Bergen-Patersoa 6/27/78 All BWR Power Reactor Hydraulic Shock Facilities with Suppressor Accumulator an OL or CP Spring Coils 78-11 Examinaticr. of Mark I 7/24/78 BWR Power Reactor Containment Torus Facilities with an OL Welds for action:

Peach Bottom 2 and 3, Quad Cities 1 and 2, Hatch 1, Monticello and Vermont Yankee. All other BWR Power Reactor Facilities with an OL for informatica b.:N Sb

IE Bulla'.in No.79-01A Date: June 6, 1979 Page 2 of 5 LISTING OF IE BULLETINS ISSUL0 IN LAST TWELVE MONTHS (CONTINUED)

Bulletin Subject Date Issued Issued To No.

78-12 Atypical Weld Material 9/29/78 All Power Reactor in Reactor Pressure Facilities with an Vessel Welds OL or CP 78-12a Atypical Weld ftaterial 11/24/78 All Power Reactor in Reactor Pressure Facilities with an Vescel Walds OL or CP 78-12B Atypical Neld Material 3/19/79 All Power Reactor in Reactor Pressure Facilities with an Vessei Welds OL or C' 78-13 Failures In Source Heads 10/27/78 All General and of Kay-Ray, Inc., Gauges Specific Licensees Models 7050, 70508, 7051, with the subject 7051B, 7060, 70608, 7061 Kay-Ray, Inc.

and 7061B Gauges 78-14 Deterioration of Buna-N 12/19/78 All GE BWR Faci-Components In ASCO lities with an OL Solenoids (for action), and all other Power Reactor Facilities with an OL or CP (for information) 79-01 Envir;nmental Qualif-2/8/79 All Power Reactor ication of Class IE Facilities with an OL, Equipment except the 11 Systematic Evaluation Program Plants (for actioni, and all other Power R< etor Facilities with ar 'l or CP (For Information) 79-02 Pipe Support Base Plate 3/8/79 All Power Reactor Design Using Concrete Facilities with an OL Expansion Anchor Bolts or CP

- ' /.

'an

,J U l /

IE Bulletin No. 79-OlA Date:

June 6,1979 Page 3 of 5 LISTING 0F IE BULLETINS ISSUED IN LAST TWELVE MONTHS (CONTINUED)

Bulletin Subject Date Issued Issued to No.

79-03 Longitudinal Weld Defects 3/12/79 All Power Reactor in ASME SA-312 Type Facilities with 304 Stainless Steel Pipe an OL or CP Spools Manufactured by Yocqgstown Welding and Engineering Company 79-04 Incorrect Weights for 3/3 9 All Power Reactor Swing Check Valves Facilities with an Manufactured by Velan OL or CP Engineering Corporation 79-05 Nuclear Incident at 4/1/79 All Babcock and Three Mile Island Wilcox Power Reactor Facilities with an OL, Except Three Mile Island 1 and 2 (For Action),

and All Other Power Reactor Faaili+.ies With an OL or CP (For Information)79-05A Nuclear Incident at 4/5/79 Same as 79-05 Three Mile Island -

Supplement 79-06 Review of Operational 4/11/79 All Pressurized Water Errors and System Mis-Power Reactor Facil-alignments Identified ities with an OL Except During the Three Mile B&W Facilities (For Incident Action), All Other Power Reactor Facil-ities with an OL or CP (For Information)

?i36 195 IE Bulletin No. 79-OlA Date:

June 6, 1979 Page 4 of 5 LISTING 0F IE BULLETINS ISSUED IN LAST TWELVE MONTHS (CONTINUED)

Bulletin Subject Date Issued Issued to No.79-06A Same Title as 79-06 4/14/79 All Westinghouse Designed Pressurized Power Reactor Facil-ities with an OL (For Action), and All Other Power Reactor Facilities with an OL or CP (For Information)79-06A Same Title as 79-06 4/18/79 All Westinghouse (Revision 1)

Designed Pressurizei Power Reactor Facil-ities with an OL (For Action), and All Other Power Reactor Facilities with an OL or CP (For Information)79-06B Same Title as 79-06 4/14/79 All Combustion Engineering Designed Pressurized Power Reactor Facilities with an OL (For Action), and All Other Power Reactor Facilities with an OL or CP (For Information) 79-07 Seismic Stress Analysis 4/14/79 All Power Reactor of Safety-Related Piping Facilitie with an OL or CP

[] '. b

$90 IE Bulletin No.79-01A Date:

June 6, 1979 Page 5 of 5 LISTING 0F IE BULLETINS ISSUED IN LAST TWELVE MONTHS (CONTINUED)

Bulletin Subject Cate Issued Issued to No.

79-08 Events Relevant to 4/14/79 All BUR Power Boiling Water Power Reactor Facilities Reactors Identified with an OL (For During Three Mile Action), All Other Island Incident Power Reactor Facil-ities with an OL or J (Far Infomation) 79-09 Failures of GE Type 4/17/79 All Dewer Reactor AK-2 Type Circuit Facilities with an Breaker in Safety CL or CP Related Systems 79-10 Requalification Training 5/11/79 All Poser Reactor Program Statistics Facilities witti an OL 79-11 Faulty Overcurrent Trip 5/22/79 All Power Reactor Device in Circuit Breakers Fttilities with an for Engineered Safety OL or CP Systems 79-12 Short Period Scrams at 5/31/79 All GE BWR Facilities BWR Facilities with an OL

!bNN

]?

ENCLOSURE 3 SEP Plants Plant Region Dresden 1 III Yankee Rowe I

Big Rock Point III San Onofre 1 V

Haddam Neck I

Lacrosse III Oyster Creek I

R. E. Ginna I

Dresden 2 III Millstone 1 I

Palisades III b.i N

')0