Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in IE Insp Rept 50-333/78-28
ML19224C591
Person / Time
Site: FitzPatrick 
Issue date: 05/21/1979
From: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Leonard J
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
Shared Package
ML19224C592 List:
References
NUDOCS 7907030054
Download: ML19224C591 (2)


See also: IR 05000333/1978028

Text

N

.

. .

,

g

UNITED STATES

.

b o

NUCLEAR REGULATORY COMMisslON

,,

I

s31 PAR AVENUE

  • Yr gig .

f

KING OF PRU551A, PENNSYLV ANI A 19406

s, ~ f

.....

MAY 211979

Docket No. 50-333

Power Authority of the State of New York

Jar.tes A. FitzPatrick Nuclear Power Plant

ATTN: Mr. J. D. Leonard

Resident Manager

P. O. Box 41

Lycoraing, New Yerk 13093

Gentlemen:

Subject:

Inspection 50-333/78-28

This refers to your letter dated February 23, 1979, in response to our

letter dated January 31, 1979, and telephone conversations between yourself,

Mr. R. Burns of your staff and Mr. Plumlee of our staff on March 8, 1979.

Based on the additional infermation supplied in your response, we have with-

drawn item B.1 and D as iters of noncompliance.

Our records have been modified

to reflect this action.

However, it is necessary that you modify your procedures

to clearly define the criteria for use or non-use of protection factors for

half face mask respirators.

We understand, based cn the telephone discussions,

that these procedures are being changed,

Your response to item C stated that the October 16, 1978 memorandum cannot

be considered a procedure revision. We fully agree with that statement.

Your procedure revisions are identified by the use of a Procedure Initiation /

Revision Request Form and by review and approval signatures that were not

provided with the memorendum.

If you wish to reduce a reqJirement of a

procedure (in this case a requirement to maintain locked gate control of

access to hign radiation areas > 100 mrem / hour but < 1,000 mrem / hour) you

are required to revise the procedure in the prescribed manner.

Your letter did not justify withdrawal of this item of noncompliance.

We note that in the Radiation Protection Operating Procedures, in Revision

1, November 17, 1978, you corrected ite:1 C.

272

3287

7907 030 Oy,

.

.

-

.

Power Authority of the State

of New York

2

Thank you for informing us of your corrective and preventive actions.

These actions will be examined during a subsequent inspection of your

licensed program.

Your cooperation with us is appreciated.

Sincerely,

B

H. Grier

Director

cc:

George T. Berry, General Manager and Chief Engineer

P. W. Lyon, Manager - Nuclear Operations

A. Klausmann, Director, Quality Assurance

M. C. Cosgrove, Quality Assurance Supervisor

J. F. Davis, Chairman, Safety Review Committee

L. R. Bennett, Assistant General Manager - General Counsel

G. M. Wilverding, Licensing Supervisor

272

328