Forwards IE Insp Rept 50-320/75-02 on 750220-21 & Notice of Violation
ML19220A902
Person / Time
Site: Crane 
Issue date: 03/17/1975
From: Robert Carlson
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Arnold R
METROPOLITAN EDISON CO.
Shared Package
ML19220A903 List:
References
NUDOCS 7904250078
Download: ML19220A902 (16)


See also: IR 05000320/1975002

Text

{{#Wiki_filter:. . ~

'.* , , , UN11ED sT ATES ~, REGUL ATORY COMMC';lON A4 NUCLEAR REclONI , 631 P ARK AVENUC 19406 // KING OF PRU$5t A. PENN5Y LV ANI A 1 7 Ui5

m e ,1 License No. CPPR-66 j Metropolitan Edison Company Inspection No. 50-320/75-02 ,trention: Mr. R. C. Arnold Vice President ~ , P.O. Box 542 Reading, Pennsylvania 19603 Centleren: . This refers to the inspection conducted by Mr. Folsom of, this i f at Middletown, Pennsylvan a o office on February 20 and 21, 1975 CPPR-66 and to the discussions activitics authorized by AEC License 50.with Mr. Levin and Mr. Stromberg of our findings held by Mr. Folso of your staff at the conclusion of the inspection. Areas exc=ined during this inspection are described in the Of fice of Inspection Report which is enclosed with Inspection & EnforeccentWithin these areas, the inspection consisted of _ selective examinations of procedures and representative records, this letter. interviews with personnel, and observations by the inspector. During this inspection, it was found that certain of your activities The items and appeared to be in violatien of AEC requirements. references to t This letter constitutes a notice sent to you pursuant to the provisions of Section 2.201 of the AEC's " Rules to this letter. of Practice", Part 2, Title 10, Code of Federal Regulations. Section 2.201 requires you to submit to this office within 30 days of your receipt of this notice, a written statement of explanation (1) corrective steps which have been or vill in reply, including: (2) corrective steps be taken by you, and the results achieved; (3) the which vill be taken to avoid further violations; and . date when full compliance vill be achieved. In accordance with Section 2.790 of the AEC's " Rules of Practice", Part 2, Title 10, Code of Federal Regulations, a copy of this letter and the enclosed inspection report vill be placed in theIf this rep NRC's Public Document Room. that you (or your contractor) believe to be proprietary, it is necessary that you make a written application within 20 days to this of fice to withhold such information from public disclosure. _ . ( $* s$ rj 9. C /1 o - e <- 0? -m g g hb' W" J I rstre.s+ O ~

7 90425 0D7E p6 ~~~

. . Metropolitan Edison Company -2- Should you have any questions concerning this inspection, we will be pleased to discuss them with you. . Sincerely, ,$ 9 sw.ww

  • /

Robert T. Carlson, Chief Facility Construction and Engineering [ Support Branch Enclosures: 1. Description of Vic~ations 2. IE Inspection Report No. 50-320/75-02 R. L. Wayne, QA Manager, Design and Construction cc: T. M. Crin= ins , Jr. , Saf ety & Licensing Manager R. k'. Heward, Jr. , Proj ect Manager W. A. Verrochi, Vice President, Design & Construction Gerald Charnoff, Esquire bec's: IE Chief, FS&EB IE:HQ (5) DL (4 w/encls plus 9 cpys of report) ~ DR Central Files PS (3) PDR , Local PDR IE Files NSIC TIC REG:1 Reading Room Miss Mary V. Southard, Chairman, Citizens for a Safe Environment ' State of Pennsylvania OCC . - .. e - }-{ ^ .(~>.C l)* _r I - I d }}