ENCLOSURE 1, ATTACHMENT 1 PRAIRIE ISLAND INDEPENDENT SPENT FUEL STORAGE INSTALLATION License Amendment Request Expand the Storage Capacity for the Independent Spent Fuel Storage Installation RENEWED LICENSE NO. SNM-2506 (Markup)

(1 Page Follows)

NRC FORM 588 (10-2000) 10 CFR 72 U. S. NUCLEAR REGULATORY COMMISSION PAGE 1

OF 7

PAGES LICENSE FOR INDEPENDENT STORAGE OF SPENT NUCLEAR FUEL AND HIGH-LEVEL RADIOACTIVE WASTE Pursuant to the Atomic Energy Act of 1954, as amended, the Energy Reorganization Act of 1974 (Public Law 93-438), and Title 10, Code of Federal Regulations, Chapter 1, Part 72, and in reliance on statements and representations heretofore made by the licensee, a license is hereby issued authorizing the licensee to receive, acquire, and possess the power reactor spent fuel and other radioactive materials associated with spent fuel storage designated below; to use such material for the purpose(s) and at the place(s) designated below; and to deliver or transfer such material to persons authorized to receive it in accordance with the regulations of the applicable Part(s). This license shall be deemed to contain the conditions specified in Section 183 of the Atomic Energy Act of 1954, as amended, and is subject to all applicable rules, regulations, and orders of the Nuclear Regulatory Commission now or hereafter in effect and to any conditions specified herein.

Licensee 1.

Northern States Power Company, a Minnesota corporation (NSPM) 1 3.

License No.

Renewed License SNM-2506 Amendment No.

10 2.

414 Nicollet Mall Minneapolis, Minnesota, 55401-1927 4.

Expiration Date October 31, 2053 5.

Docket or Reference No.

72-10 6.

Byproduct, Source, and/or Special Nuclear Material 7.

Chemical or Physical Form 8.

Maximum Amount That Licensee May Possess at Any One Time Under This License A. Spent fuel assemblies from Prairie Island Nuclear Generating Plant (PINGP),

using natural water for cooling and enriched not greater than 3.85 (TN-40) and not greater than 5.00 (TN-40HT) percent U-235, and associated radioactive materials related to receipt, storage and transfer of the fuel assemblies B. Irradiated fuel assembly inserts from the PINGP. An insert may be a burnable poison rod assembly (BPRA) or a thimble plug device (TPD).

A. As UO2 clad with zirconium or zirconium alloys B

SS 304 structure, Inconel 718 spring, and borated pyrex glass.

A.

715.29 TeU of spent fuel assemblies B. One BPRA or TPD per spent fuel assembly.

1 Northern States Power Company was incorporated in Minnesota as a wholly owned subsidiary of Xcel Energy Inc., effective August 18, 2000. This license reflects the Commissions consent per 10 CFR Part 72, Section 72.50, to the license transfer approved by Order dated May 12, 2000.

9.

Authorized Use: For use in accordance with the conditions in this license and the Technical Specifications contained in Appendix A. The basis for this license was submitted in the Safety Analysis Report dated August 31, 1990, and supplements dated October 29, 1990; April 2, June 5, October 9 1,049.60 11

-~

ENCLOSURE 1, ATTACHMENT 2 PRAIRIE ISLAND INDEPENDENT SPENT FUEL STORAGE INSTALLATION License Amendment Request Expand the Storage Capacity for the Independent Spent Fuel Storage Installation ISFSI SAFETY ANALYSIS REPORT AND ADDENDUM (Markup - For Information Only)

(52 Pages Follow)

PRAIRIE ISLAND INDEPENDENT SPENT FUEL STORAGE INSTALLATION SAFETY ANALYSIS REPORT Revision: 9 Page 2.5-4 The drilling and surveying of boring locations and elevations were performed by Twin City Testing, Inc. The borings were drilled utilizing a Central Mining Equipment, Model 55, truck-mounted drilling rig. Borings were advanced using 6 in.

diameter, hollow stem augers from the surface down to the intersection with the ground water table. At this point a switch to mud-rotary drilling was undertaken.

Borings were advanced below the water table utilizing a 2 15/16 in. diameter tricone bit and gel/water mud. Boring B-8, B-10, B-12, B-14 and B-16 were drilled to 61 ft.,

and borings B-9, B-11, B-13 and B-15 were drilled to 51 ft. Samples were collected at 5 or 10 foot intervals with a standard split spoon sampler driven with a 140 lb.

hammer following the ASTM D1586 standard penetration test (SPT) procedure (Reference 8). Blow counts, sample descriptions and water level elevations were recorded, and samples were collected for testing. Boring logs prepared for the nine borings are shown in Appendix 2A.

Fourteen soil samples, representing the various soil types encountered, were tested by Twin City Testing, Inc., for grain size distribution using ASTM D422 (Reference

9) procedures. The results of these tests are set forth in Appendix 2B.

2.5.1.6 GEOLOGIC PROFILES Based on the information gathered from the 9 borings and associated samples obtained in June 1991, the following stratigraphic sequence is inferred to underlay the site. The site is covered with a layer of reddish brown silty sand from 0 to 12 ft in depth. Underlying the top layer is a uniform light brown fine sand with intermittent thin gravel seams. The light brown sand is found between depths of 12 ft and 44 to 46 ft. Below the light brown fine sand gravelly sand exists. The gravelly sand contains gravel pieces to 1 3/4 in. in size and is found between depths of 44 to 46 ft and 61 ft, the depth of the deepest boring. This sequence of soil layers was found in all 9 borings.

The density of the soils as measured by Standard Penetration Test (SPT) blow counts generally increases with depth from the surface. Penetration resistance down to the intersection with the marked increase in gravel content (approximately elevation 44 to 46 ft.) ranges from 3 to 28 blows/ft. Below this elevation the penetration resistance generally increases and ranges from 8 to 45 blows/ft.

The depth to ground water table was measured in each of the borings through hollow steam augers prior to switching to mud-rotary drilling. The ground water was measured at depths from 16.0 to 20.7 ft. below ground surface.

2.5.1.7 PLAN AND PROFILE DRAWINGS Figure 2.5-6 is a site grading plan. Figure 2.5-7 shows site sections and details.

See Insert S-2 See Insert S-1

Insert S-1 for page 2.5-4:

ISFSI Expansion To support the ISFSI expansion, additional field investigations at the ISFSI site were made in July 2018. The field program consisted of performing four soundings (CPT-1 through CPT-4) located directly south of the eastern original pad as shown in Appendix 2C. The drilling and surveying of locations and elevations were performed by Braun Intertec Corporation.

The work consisted of a series of four seismic Cone Penetration Test (CPT) soundings performed in accordance with ASTM D3740 (Reference 13). CPT soundings for this project were performed using designated push equipment manufactured by A.P. van den Berg. The rig is mounted on a rubber-tracked Marooka carrier and is capable of generating 15 tons of reaction force. CPT soundings were performed using an A.P. van den Berg icone (60 degree cone apex and 15 square centimeter tip area) with porous stones mounted in the U2 position. Seismic testing was performed at one meter intervals and shear wave (S-wave) and compressive wave (P-wave) data was obtained in general accordance with procedures described in ASTM D5778 (Reference 14) and D7400 (Reference 15) at all four CPT locations. The shear wave velocity (Vs) and compression wave velocity (Vp) was estimated based on the wave arrival times to the A.P. van den Berg geophone module attached to the icone. Shallow refusal of the cone was encountered at every sounding location due to apparent dense soil layers or other obstructions.

Each sounding was terminated when the equipment reached 90 percent of its maximum capacity. Refer to Appendix 2C for additional information.

Additional soil property data to support the geotechnical investigation was used from SPT boring log ST-5, which was obtained by Braun Intertec in August 2014 to support construction of the nearby FLEX Equipment Storage Building. This boring log is included in Appendix 2C.

Insert S-2 for page 2.5-4:

ISFSI Expansion A total of four new CPT soundings were performed to support the southeast ISFSI pad expansion. Boring logs of soil properties vs. depth similar to the nine borings drilled in 1991 were not obtained since the CPT method was used for the southeast pad evaluation. However, SPT boring log ST-5 obtained in 2014 for the nearby FLEX Equipment Storage Building shows a stratigraphic sequence consistent with the 1991 boring logs. The groundwater level was measured by CPT-1 through CPT-4 at a depth of 13 ft. below ground surface in the ISFSI expansion area.

PRAIRIE ISLAND INDEPENDENT SPENT FUEL STORAGE INSTALLATION SAFETY ANALYSIS REPORT Revision: 9 Page 2.5-7 A liquefaction analysis was performed on the basis of standard penetration test N values (blow counts) obtained during the June 1991 site investigation (Reference 12). The analysis is based on a normal water table elevation of approximately 18 ft.

below the ground surface, since it is not intended to evaluate flood and earthquake conditions together. The liquefaction analysis was performed using a procedure developed by Seed, Seed and Idriss (Reference 11). Following this procedure, the stress ratio, which is the ratio of horizontal shear stress to vertical effective stress, is calculated at various depths for the anticipated horizontal acceleration N values which would allow liquefaction, given the expected stress ratio, is then determined.

A curve of these critical N values versus depth (Figure 2.5-9) was developed for a maximum horizontal ground acceleration of 0.12g for a Richter magnitude 5 earthquake. This curve is compared with the N value profile for each of the borings as shown in Figure 2.5-9. The comparison shows that two marginally liquefiable zones were found in the borings at depths of 20 ft. and 35 ft. throughout the site.

The potentially liquefiable zone at 20 ft. is only 2 ft. below the groundwater table and any pore water pressure buildup due to strong ground shaking would dissipate quickly due to the short drainage path to the top of the ground water. Therefore, there is little chance of this layer liquefying. The potentially liquefiable zone at 35 ft.

was analyzed based on the ratio of the depth of the unliquefiable surface layer to the thickness of the liquefiable sand layer. In comparison to numerous similar sites noted in Reference 11, if the marginally liquefiable (at the 35 ft. depth) is taken to be 5ft. thick, based on the low blow count (N) values shown in Figure 2.5-9, then the ratio between layer depth and layer thickness is 7. According to observations mentioned in Reference 11 surface effects are not expected at ratios above 1.

The studies from Reference 11 also state that no evidence of liquefaction was found when nonliquefiable surface layer has a thickness of greater than 9 ft. For these reasons, even if liquefaction of the sand layer at 35 ft. were to occur, it is anticipated that the effects at the surface will be minor to non-existent and will have no effect on the stability of the ISFSI slabs.

2.5.5 SLOPE STABILITY The ISFSI site within the perimeter fence is located on both cut and fill material.

The berms surrounding the site are constructed of earth fill material. To limit the site area and amount of required fill, a slope of one horizontal to one vertical is used for the berms.

The berms are reinforced with geofabric. Erosion control material and natural vegetation give the berms a natural appearance.

See Insert S-4

Insert S-4 for page 2.5-7:

ISFSI Expansion The liquefaction potential for the design of the additional ISFSI pad was evaluated based on the data from borings CPT-1 through CPT-4, as well as the 1991 SPT borings (Reference 16). The methods are in accordance with NRC Regulatory Guide 1.198 (Reference 17) for the safe shutdown earthquake (SSE). Based on the results of the analysis, generally the factor of safety against liquefaction is greater than 2.0 in the subsurface profile based on the CPT method and greater than 1.65 with the SPT method using conservative approaches. Therefore, the pad location is not susceptible to liquefaction and is acceptable. By taking into account the calculated factors of safety for the site, seismic induced settlement is considered to be minimal.

PRAIRIE ISLAND INDEPENDENT SPENT FUEL STORAGE INSTALLATION SAFETY ANALYSIS REPORT Revision: 17 Page 2.6-1

2.6 REFERENCES

1.

Northern States Power Company, Prairie Island Nuclear Generating Plant Updated Safety Analysis Report, Revision 18, Docket 50-282 (Unit 1) and 50-306 (Unit 2).

2.

KLD Engineering, P.C., Evacuation Time Estimate for the Prairie Island Nuclear Generating Plant Emergency Planning Zone, November 2012.

3.

National Oceanic and Atmospheric Administration, Local Climatological Data Minneapolis - St. Paul, MN, July 1987.

4.

Uman, Martin A., Understanding Lightning, Bek Technical Publications, Inc.,

Carnegie, PA 15106.

5.

Northern States Power Company, Prairie Island Nuclear Generating Plant Final Safety Analysis Report, May 3, 1974.

6.

U.S. Nuclear Regulatory Commission, Regulatory Guide 1.145, Atmospheric Dispersion Models for Potential Accident Consequence Assessments at Nuclear Power Plants, Revision 1, November 1982.

7.

Northern States Power Company, Operating Procedure AB-4, Flood, Revision 13.

8.

American Society for Testing and Materials, ASTM D1586, Penetration Test and Split-Barrel Sampling of Soils, 1984.

9.

American Society for Testing and Materials, ASTM D422, Method for Particle-Size Analysis of Soils, 1963.

10. Peck, Hanson, and Thornburn, Foundation Engineering, 2nd Edition, John Wiley &

Sons, 1974.

11. Committee on Earthquake Engineering, Commission on Engineering and Technical Systems, National Research Council, Liquefaction of Soils During Earthquakes, National Academy Press, Washington, D.C., 1985.
12. Estimation of Liquefaction Potential, SWEC Calculation No. 1291154-G-2, Rev. 1, July 20, 1991.

01441968

13. American Society for Testing and Materials, ASTM D3740-12a, Standard Practice for Minimum Requirements for Agencies Engaged in Testing and/or Inspection of Soil and Rock as Used in Engineering Design and Construction.
14. American Society for Testing and Materials, ASTM D5778-12, Standard Test Method for Electronic Friction Cone and Piezocone Penetration Testing of Soils.
15. American Society for Testing and Materials, ASTM D7400-17, Standard Test Methods for Downhole Seismic Testing
16. Soil Liquefaction Analysis for ISFSI Pad Expansion, Sargent & Lundy Calculation No. 2018-04540, Rev. 0.
17. U.S. Nuclear Regulatory Commission, Regulatory Guide 1.198, Procedures and Criteria for Assessing Seismic Soil Liquefaction at Nuclear Power Plant Sites, November 2003.

I\\

PRAIRIE ISLAND INDEPENDENT SPENT FUEL STORAGE INSTALLATION SAFETY ANALYSIS REPORT Revision: 16 Page 3.1-1 SECTION 3 PRINCIPAL CASK DESIGN CRITERIA 3.1 PURPOSES OF CASK 3.1.1 SPENT FUEL TO BE STORED The ISFSI is designed to accommodate a total of 48 storage casks. Each of the casks is capable of accommodating 40 spent fuel assemblies. The total capacity of the fuel to be stored at the facility is 715.29 metric tons of uranium (MTU). This is based on storage of 482 Westinghouse standard assemblies (400 kgU/each), 481 Exxon's standard and TOPROD assemblies (370 kgU/each) and 957 Westinghouse optimized design assemblies (360 kgU/each).

Physical characteristics of the fuel to be stored in the ISFSI are described in detail in Chapter 3 of the Prairie Island USAR (Reference 1) and are summarized in Table 3.1-1.

The following fuel assembly characteristics constitute limiting parameters for storage of specific assemblies at the ISFSI:

x Initial Fuel Enrichment: shall be limited to a maximum of 3.85 weight percent U-235 x Fuel Burnup: shall be limited to a maximum burnup of 45,000 MWD/MTU x Decay Time: shall be limited to a minimum of 10 years x Physical Configuration/Condition: fuel assembly shall be intact, shall have no known cladding defects and shall not have physical damage which would inhibit insertion or removal from the cask fuel basket.

Only spent fuel which meets the requirements specified in Chapter 10 and the ISFSI Technical Specifications will be stored in the ISFSI.

The thermal and radiological characteristics for the spent fuel were generated using the ORIGEN2 computer code (Reference 2). These characteristics for the Westinghouse OFA 14x14 assembly are shown in Table 3.1-2. For the thermal and radiological characteristics, the Westinghouse 14x14 OFA assembly with an enrichment of 3.85 w/o U-235 was chosen. The OFA assembly contains the largest "structural" mass of all the assembly types. It was assumed to contain 380 kgU, which is the average of all assemblies. Analyses are included in Section 3.3.4.

1,049.60 64 64 casks with 40 spent fuel assemblies each and the maximum design initial Uranium content, for both TN-40 and TN-40HT casks, of 410 kgU per assembly.

r

35$,5,(,6/$1',1'(3(1'(1763(17)8(/6725$*(,167$//$7,21 6$)(7<$1$/<6,65(3257

Revision: 17 Page A3.3-28 The average cask surface temperature in the detailed cask model is 242 qF while the average cask surface temperature in the storage array model is 260 qF. This shows a temperature increase of 18 qF due to the cask view factors.

The calculated average resin temperature at the hottest cross section of the detailed model is 267 qF. The addition of the storage pad to the cask view factor calculation increases the average resin temperature at the hottest cross section by at most 18 qF to 285 qF. This temperature remains below the allowable limit of 300 qF for the radial resin.

Since the basket temperatures calculated in the TN-40HT detailed model remain unaffected, these temperatures can be used for calculation of the thermal stress, thermal expansion, and cask cavity pressure for the structural evaluation.

The view factors from the emitting cask (shown in Figure A3.3-20) to other casks and to the storage pad are calculated from the storage array model. These view factors are compared in Table A3.3-11 to the values calculated in Section 3.3.2.2.1 for information purposes only.

Effective Conductivity for Cask Sections To calculate the axial and the radial effective conductivities of the cask sections shown in Figure A3.3-22, corresponding nodes and elements for each section are selected from the detailed finite element model of the TN-40HT cask.

To calculate the axial effective conductivity of each cask section, constant temperature boundary conditions are applied at the top and bottom of that section. The value of reaction solution for the colder surface is retrieved from the model using PRNDL command (Reference 36) after solution was completed. Since the model is quarter symmetric, the amount of heat leaving the colder surface is four times the reaction solution resulted from PRNLD command. The axial effective conductivity is calculated using the following equation:

7

/

4 N

D[O HII u

u Q = Amount of heat leaving the colder face of the cask section = Qreaction u 4 L = Length of the cask section A = Surface area of the colder face (upper face) of the cask section

= S (r2 2 - r1

2) r1 = Cask cavity radius = 36 for cask sections 1 through 4, 0 for cask section 5 r2 = Outer radius of the cask section

= 44.75 for cask sections 1, 2, and 4

= 50.5 for cask section 3

= 36 for cask section 5 INSERT T-1: Impact of Southeast ISFSI Pad Expansion

Insert T-1 for page A3.3-28:

Impact of Southeast ISFSI Pad Expansion As discussed in Section A3.3.2.2.4.1, the view factor in the detailed TN-40HT cask model is based on a cask alignment of two rows of infinite length, which is conservative for the existing configuration. As shown in Figure A3.3-20 and documented in the existing analysis, the view factors from the emitting cask to the receiving casks beyond cask 5 are not considered in the calculation due to their negligible effect.

Note that the distance from the emitting cask to cask 5 is approximately, (18 ft.2 + (4 x 18 ft.)2)0.5 74 ft., and the distance between the closest cask on the existing northwest ISFSI pad and the southeast ISFSI pad is approximately,

((9 ft. + 40 ft. + 9 ft.)2 + (11 ft. + 38 ft. + 9 ft.)2)0.5 82 ft., given a 38 ft. separation between the existing northeast ISFSI pad and the southeast ISFSI pad. As such, the southeast ISFSI pad installation does not affect the calculated view factors used in the detailed TN-40HT cask model.

However, similar to how to the storage array model was used to estimate the increase in the cask outer shell temperature due to the concrete pad and the service road, the effect on the average cask surface temperature due to the addition of a southeastern ISFSI pad should be evaluated for the existing northeastern pad. The impact of the southeast IFSI pad, fully loaded with TN-40HT casks, on the existing northeast ISFSI pad, fully loaded with TN-40HT casks, on the radiant heat transfer between the casks, ground, and environment is evaluated with the use of a computational fluid dynamics (CFD) model. The CFD model is developed using STAR-CCM+ (Reference 49). STAR-CCM+ is a commercially available computer code developed by Siemens Product Lifecycle Management Software Inc.

This model evaluated the radiation heat transfer between the casks, ground, and environment but did not model air flow around the cask (i.e., convection is modeled as a boundary condition),

similar to how the ANSYS model evaluates radiant heat transfer. Although heat conduction through the casks and ground is also included in the models, only the temperature distributions on the outer surfaces of the casks are to be regarded as valid results since the internal details of the casks and conduction heat transfer through solid casks were modeled in a simplified manner. For both casks and ground, the thermal conductivity is considered using three parametric runs with values ranging from 0.5 W/m-K to 5.0 W/m-K in order to envelop typical expected values. The model is discretized in approximately 300,000 cells. A benchmark was performed against the results of the existing storage array model using a CFD model case with one set of two rows of casks, and it was determined that the CFD model yields cask exterior temperature results that were essentially the same as the ANSYS storage array model. Another case with two sets of two rows of casks with pads spaced 38 ft. apart was used to determine the maximum and average cask exterior temperatures, as shown in Table A3.3-10A. This model is shown in Figure A3.3-21A. Additional conservatism to address the modeling uncertainty was then incorporated into the results of the CFD analysis so that the cask surface temperature is conservatively considered to increase by 5 °F.

As previously discussed in this section, the storage array model results in Table A3.3-10 demonstrated an increase in the average cask surface temperature of 18 °F that corresponded to an increase in the average cask inner shell temperature of 1 °F or less, as compared to the detailed TN-40HT cask model. These results are scaled to estimate an increase in the internal cask temperatures, due to the addition of the southeast ISFSI pad, as shown below.



This would indicate the effect of the southeast ISFSI pad on average cask interior temperature is also less than 1 °F (i.e., 0.28 °F). In order to conservatively evaluate the impact of the southeast ISFSI pad. The overall increase in cask inner average temperatures of 1.28 °F (i.e., 1 °F from the existing storage array model and an additional 0.28 °F for the effect of the southeast ISFSI pad) is conservatively rounded to 2 °F and used to confirm the remaining margin for design limits is sufficient.

As before, since the basket temperatures calculated in the TN-40HT detailed model remain relatively unaffected, these temperatures can continue to be used for calculation of the thermal stress, thermal expansion, and cask cavity pressure for the structural evaluation.

Further thermal analysis and review of allowable limits associated with cask exterior and interior temperatures (including the effects on internal pressure and thermal expansion) was performed and demonstrated that there is sufficient margin to account for an increase in the cask exterior temperatures of 5°F and increase in the interior temperatures of 2 °F.

35$,5,(,6/$1',1'(3(1'(1763(17)8(/6725$*(,167$//$7,21 6$)(7<$1$/<6,65(3257

Revision: 16 Page A3.6-4 44.

ANSYS Computer Code and Users Manuals, Version 10.0.

45.

USNRC, Regulatory Issue Summary 2013-11, Resolution of Licensing Process Expectations for Pressurized Water Reactor Fuel Assemblies Susceptible to Top Nozzle Stress Corrosion Cracking in Dry Cask Spent Fuel Storage and Transportation; September 4, 2013 46.

NSP Design Change No 99FH02, Repair Regions D, E and F Spent Fuel Assemblies, Rev 0.

47.

10CFR72.48 Safety Evaluation 573, Rev 0 48.

Knoll, R.W., et al., Evaluation of Cover Gas Impurities and Their Effects on the Dry Storage of LWR Spent Fuel, PNL-6365, DE88 003983, PNNL, November 1987.

01409868 01475731

49. Siemens Product Lifecycle Management Software Inc., STAR-CCM+,

Version 12.02 (Sargent & Lundy, LLC (S&L) Program No. 03.7.863-12.02).

35$,5,(,6/$1',1'(3(1'(1763(17)8(/6725$*(,167$//$7,21 6$)(7<$1$/<6,65(3257

Revision: 15 TABLE A3.3-3 MAXIMUM TEMPERATURES FOR HOT NORMAL/OFF-NORMAL CONDITIONS Normal/Off-Normal Storage, 100 qqF Ambient Component Maximum Temperature (qF)

Temperature Limit (qF)

Fuel Cladding 694 752 Fuel Compartment 645 Basket Rails 469 Cask Inner Shell

  • 305 Shield Shell*

298 Radial Resin 285 300 Cask Outer Shell 260 Top Shield Plate 194 Cask Lid 191 Top Resin 191 300 Protective Cover 159 Inner Bottom Plate 369 Bottom Shield 265 Lid Seal 184 536 Vent & Port Seal 185 536

  • This value is the average temperature at the hottest cross section.

This value is the volumetric average temperature at the hottest cross section plus 18 qF to bound the effects of storage pad on the cask view factor. See Section A3.3.2.2.4 for discussion.

164 An additional 5 °F is added to account for the effect of the southeast ISFSI pad expansion on cask exterior temperatures. See Section A3.3.2.2.4.1.1 for discussion.

An additional 2 °F is added to account for the effect of the southeast ISFSI pad expansion on cask interior temperatures. See Section A3.3.2.2.4.1.1 for discussion.

696 647 471 307 303 290 265 199 196 196 374 270 189 190

35$,5,(,6/$1',1'(3(1'(1763(17)8(/6725$*(,167$//$7,21 6$)(7<$1$/<6,65(3257

Revision: 15 TABLE A3.3-4 AVERAGE TEMPERATURES AT THE HOTTEST CROSS SECTION FOR 100 qF STORAGE CONDITIONS Component Average Temperature (qF)

Basket 494 Aluminum Shims 373 Cask Inner Shell 305 Basket Support Bar 90-270 550 Basket Support Bar 0-180 575 Basket Aluminum Plate 90-270 551 Basket Aluminum Plate 0-180 587 Shield Shell 298 An additional 2 °F is added to account for the effect of the southeast ISFSI pad expansion on cask interior temperatures, with the exception of the Shield Shell. An additional 5 °F is added to the Shield Shell average temperature to account for the effect of the southeast ISFSI pad expansion on cask exterior temperatures.

See Section A3.3.2.2.4.1.1 for discussion.

496 375 307 552 577 553 589 303

35$,5,(,6/$1',1'(3(1'(1763(17)8(/6725$*(,167$//$7,21 6$)(7<$1$/<6,65(3257

Revision: 15 TABLE A3.3-5 MAXIMUM TEMPERATURES FOR COLD NORMAL/OFF-NORMAL CONDITIONS Normal/Off-Normal Storage, -40 qqF Ambient Component Maximum Temperature (qF)

Fuel Cladding 596 Fuel Compartment 543 Basket Rails 362 Cask Inner Shell

  • 188 Shield Shell*

181 Radial Resin 167 Cask Outer Shell 141 Top Shield Plate 62 Cask Lid 58 Top Resin 58 Protective Cover 21 Inner Bottom Plate 252 Bottom Shield 137 Lid Seal 52 Vent & Port Seal 52

  • This value is the average temperature at the hottest cross section.

This value is the volumetric average temperature at the hottest cross section plus 18 qF to bound the effects of storage pad on the cask view factor. See Section A3.3.2.2.4 for discussion.

An additional 5 °F is added to account for the effect of the southeast ISFSI pad expansion on cask exterior temperatures. See Section A3.3.2.2.4.1.1 for discussion.

An additional 2 °F is added to account for the effect of the southeast ISFSI pad expansion on cask interior temperatures. See Section A3.3.2.2.4.1.1 for discussion.

598 545 364 190 186 172 146 67 63 26 57 57 63 257 142

35$,5,(,6/$1',1'(3(1'(1763(17)8(/6725$*(,167$//$7,21 6$)(7<$1$/<6,65(3257

Revision: 15 TABLE A3.3-6 MAXIMUM COMPONENT TEMPERATURE FOR FIRE ACCIDENT Component Temperature (qF)

Time (hr)

Limit (qF)

Fuel Cladding 788 f

1058 Fuel Compartment 742 f

Basket Rails 553 f

Cask Inner Shell

  • 370 f

Shield Shell*

361 f

Radial Resin N/A Cask Outer Shell 913 End of fire Top Shield Plate 253 1.2 hr after fire Cask Lid 367 End of fire Top Resin N/A Protective Cover 1238 End of fire Lid Seal 374 End of fire 536 Vent & Port Seal 265 1.2 hr after fire 536

  • This value is the average temperature at the hottest cross section.

This value is the volumetric average temperature at the hottest cross section plus 18 qF to bound the view factor effects on the initial temperatures. See Section A3.3.2.2.4 for discussion.

Neutron shield resin is assumed to be burnt and decomposed during the fire An additional 2 °F is added to account for the effect of the southeast ISFSI pad expansion on cask interior temperatures. See Section A3.3.2.2.4.1.1 for discussion.

An additional 5 °F is added to account for the effect of the southeast ISFSI pad expansion on cask exterior temperatures. See Section A3.3.2.2.4.1.1 for discussion.

790 744 555 372 366 918 258 372 1243 379 270

35$,5,(,6/$1',1'(3(1'(1763(17)8(/6725$*(,167$//$7,21 6$)(7<$1$/<6,65(3257

Revision: 15 TABLE A3.3-7 MAXIMUM COMPONENT TEMPERATURES FOR BURIED CASK Component Temperature (qF)

Time (hr)

Limit (qF)

Fuel Cladding 1058 93 1058 Fuel Compartment 1024 93 Basket Rails 889 93 Cask Inner Shell

  • 774 93 Shield Shell
  • 769 93 Radial Resin
  • 300 1.85 300 Cask Outer Shell
  • 779 93 Top Shield Plate **

319 93 Cask Lid **

316 93 Top Resin 300 85.75 300 Protective Cover **

316 93 Lid Seal **

317 93 536 Vent & Port Seal **

316 93 536

  • This value is the volumetric average temperature at the hottest cross section plus 18 qF to bound the view factor effects on the initial temperatures. See Section A3.3.2.2.4 for discussion.
    • Based on conservative results for 95.75 hours8.680556e-4 days <br />0.0208 hours <br />1.240079e-4 weeks <br />2.85375e-5 months <br /> after the cask is buried.

An additional 2 °F is added to account for the effect of the southeast ISFSI pad expansion on cask interior temperatures. See Section A3.3.2.2.4.1.1 for discussion.

An additional 5 °F is added to account for the effect of the southeast ISFSI pad expansion on cask exterior temperatures. See Section A3.3.2.2.4.1.1 for discussion.

This value is the volumetric average temperature at the hottest cross section.

92.49 92.51 92.56 92.6 92.61 92.1 81.82 1.23 91.92 91.92 92.7 92.15 92.1 (FUEL ASSEMBLY WITHOUT BPRAS)

_____.~

/

--~

I I

/

---~

I I

35$,5,(,6/$1',1'(3(1'(1763(17)8(/6725$*(,167$//$7,21 6$)(7<$1$/<6,65(3257

Revision: 13 TABLE A3.3-10 COMPARISON OF MAXIMUM AND AVERAGE TEMPERATURES Storage Array Model TN-40HT Detailed Model Maximum Temp (qF)

Average Temp (qF)

Maximum Temp (qF)

Average Temp (qF)

Cask Inner Shell 331 306 310 305 Cask Outer Shell 276 260 244 242 Radial Resin 283 267 Insert New Table A3.3-10a after this table (on new page, if necessary)

TABLE A3.3-10A CFD MODEL COMPARISON OF MAXIMUM AND AVERAGE TEMPERATURES WITH A SOUTHEAST ISFSI PAD Thermal conductivity of cask / ground Cask Maximum Casks Average Temperature Difference [°F]

[W/m-K]

Temperature [°F]

Temperature [°F]

Cask Maximum Cask Average One set of two rows 0.5 271.8 257.2 Reference Value Reference Value Two sets of two rows - 38 ft apart 0.5 274.6 258.7

+2.8

+1.5 One set of two rows 2.5 270.7 257.0 Reference Value Reference Value Two sets of two rows - 38 ft apart 2.5 273.5 258.5

+2.8

+1.5 One set of two rows 5.0 269.7 257.0 Reference Value Reference Value Two sets of two rows - 38 ft apart 5.0 272.3 258.4

+2.6

+1.4

35$,5,(,6/$1',1'(3(1'(1763(17)8(/6725$*(,167$//$7,21 6$)(7<$1$/<6,65(3257

Revision: 15 TABLE A3.3-15 CASK INTERNAL PRESSURE (FUEL ASSEMBLY WITHOUT BPRAS)

Operating Condition nback fB nfree ntotal T cavity Pcavity (lb-mole)

(---)

(lb-mole)

(lb-mole)

(qF)

(psia)

(psig)

Normal 0.580 0.01 0.889 0.589 464 27.8 13.1 Off-Normal 0.580 0.10 0.889 0.669 464 31.6 16.9 Fire Accident 0.580 1.00 0.889 1.469 603 79.9 65.2 Buried Cask Accident

@ 95.75 hr 0.580 1.00 0.889 1.469 925 104.1 89.4 92.6 605 80.1 65.4 466 31.7 17.0 466 27.9 13.2 An additional 2 °F is added to average Tcavity to account for the effect of the southeast ISFSI pad expansion on cask interior temperatures. See Section A3.3.2.2.4.1.1 for discussion. Pcavity is recalculated based on the new temperature. There is no impact on the buried cask accident values because the maximum temperature reached is unchanged and only the time is adjusted.

CJ---i rCJ

\\-

I I

'V_

VI' -~ D I

r ~-

35$,5,(,6/$1',1'(3(1'(1763(17)8(/6725$*(,167$//$7,21 6$)(7<$1$/<6,65(3257

Revision: 15 TABLE A3.3-16 CASK INTERNAL PRESSURE (FUEL ASSEMBLY WITH BPRAS)

Operating Condition nback fB nfree ntotal T cavity Pcavity (lb-mole)

(---)

(lb-mole)

(lb-mole)

(qF)

(psia)

(psig)

Normal 0.549 0.01 1.017 0.559 464 27.9 13.2 Off-Normal 0.549 0.10 1.017 0.651 464 32.5 17.8 Fire Accident 0.549 1.00 1.017 1.566 603 89.9 75.2 Buried Cask Accident

@ 75 hr 0.549 1.00 1.017 1.566 843 110.2 95.5 74.6 466 28.0 13.3 605 80.1 75.4 17.9 466 32.6

  • An additional 2 °F is added to average Tcavity to account for the effect of the southeast ISFSI pad expansion on cask interior temperatures. See Section A3.3.2.2.4.1.1 for discussion. Pcavity is recalculated based on the new temperature. There is no impact on the buried cask accident values because the maximum temperature reached is unchanged and only the time is adjusted.

35$,5,(,6/$1',1'(3(1'(1763(17)8(/6725$*(,167$//$7,21 6$)(7<$1$/<6,65(3257

Revision: 16 TABLE A3.3-36 TEMPERATURES FOR OFF-NORMAL STORAGE CONDITIONS WITH LOWER POISON PLATE CONDUCTIVITY Design Basis Model Off-Normal Storage 100qF ambient (Table A3.3-3)

Lower Conductivity Model Off-Normal Storage 100qF ambient Component Maximum Temperature (qF)

Maximum Temperature (qF)

Temperature Limit (qF)

Fuel Cladding 694 672 752 Fuel Compartment 645 644 Basket Rails 469 469 Inner Bottom Plate 369 368 Bottom Shield 265 265 Cask Inner Shell

  • 305 305 Shield Shell
  • 298 298 Radial Resin 285 285 300 Cask Outer Shell 260 260 Average Cavity Gas ( T cavity) 464 **

458 This value is the volumetric average temperature at the hottest cross section.

This value is the volumetric average temperature at the hottest cross section plus 18 °F to bound the effects of storage pad on the cask view factor. See Section A3.3.2.2.4 for discussion.

This value is taken from Table A3.3-15.

01424752 466 696 647 471 374 270 307 303 290 265 An additional 2 °F is added to account for the effect of the southeast ISFSI pad expansion on cask interior temperatures. See Section A3.3.2.2.4.1.1 for discussion.

An additional 5 °F is added to account for the effect of the southeast ISFSI pad expansion on cask exterior temperatures. See Section A3.3.2.2.4.1.1 for discussion.

674 646 471 373 270 307 303 290 265 460

35$,5,(,6/$1',1'(3(1'(1763(17)8(/6725$*(,167$//$7,21 6$)(7<$1$/<6,65(3257

Revision: 16 TABLE A3.3-37 TEMPERATURES FOR FIRE ACCIDENT CONDITIONS WITH LOWER POISON PLATE CONDUCTIVITY Design Basis Model Fire Accident (Table A3.3-6)

Lower Conductivity Model Fire Accident Transient / Steady State Transient Steady State Component Maximum Temperature (qF)

Time (hr)

Maximum Temperature (qF)

Time (hr)

Maximum Temperature (qF)

Time (hr)

Temperature Limit (qF)

Fuel Cladding 788 f

692 36.7 687 f

1058 Fuel Compartment 742 f

666 36.7 661 f

Basket Rails 553 f

493 12.7 486 f

Cask Inner Shell

  • 370 f

351 2.0 323 f

Shield Shell

  • 361 f

322 0.25 (end of fire) 316 f

Radial Resin N/A N/A N/A Cask Outer Shell 913 0.25 (end of fire) 911 0.25 (end of fire) 277 f

Average Cavity Gas

( T cavity) 603 **

f 481 36.7 475 f

This value is the volumetric average temperature at the hottest cross section.

This value is the volumetric average temperature at the hottest cross section plus 18 °F to bound the effects of storage pad on the cask view factor. See Section A3.3.2.2.4 for discussion.

Neutron shield resin is assumed to be burnt and decomposed during the fire This value is taken from Table A3.3-15.

01424752 An additional 2 °F is added to account for the effect of the southeast ISFSI pad expansion on cask interior temperatures. See Section A3.3.2.2.4.1.1 for discussion.

790 744 555 372 366 918 605 483 477 916 282 327 321 353 325 495 488 668 663 694 689 An additional 5 °F is added to account for the effect of the southeast ISFSI pad expansion on cask exterior temperatures. See Section A3.3.2.2.4.1.1 for discussion.

§

35$,5,(,6/$1',1'(3(1'(1763(17)8(/6725$*(,167$//$7,21 6$)(7<$1$/<6,65(3257

Revision: 16 TABLE A3.3-38 TEMPERATURES FOR BURIED CASK ACCIDENT CONDITIONS WITH LOWER POISON PLATE CONDUCTIVITY Design Basis Model Buried Cask Accident (Table A3.3-7)

Lower Conductivity Model Buried Cask Accident Component Maximum Temperature (qF)

Time (hr)

Maximum Temperature (qF)

Time (hr)

Temperature Limit (qF)

Fuel Cladding 1058 93 907 93 1058 Fuel Compartment 1024 93 890 93 Basket Rails 889 93 759 93 Cask Inner Shell

  • 774 93 650 93 Shield Shell
  • 769 93 646 93 Radial Resin 300 1.85 299 1.85 300 Cask Outer Shell 779 93 637 93 Average Cavity Gas ( T cavity) 925 **

93 735 93 This value is the volumetric average temperature at the hottest cross section.

This value is the volumetric average temperature at the hottest cross section plus 18 °F to bound the effects of storage pad on the cask view factor. See Section A3.3.2.2.4 for discussion.

This value is taken from Table A3.3-15.

01424752 92.6 1.19 1.23

An additional 5 °F is added to the Lower Conductivity Model Buried Cask Accident maximum temperatures to account for the effect of the southeast ISFSI pad expansion on cask exterior temperatures. See Section A3.3.2.2.4.1.1 for discussion.

(FUEL ASSEMBLY WITHOUT BPRAS) 92.49 92.51 92.56 92.6 92.61 92.1 909 892 761 652 651 642 737 An additional 2 °F is added to the Lower Conductivity Model Buried Cask Accident maximum temperatures to account for the effect of the southeast ISFSI pad expansion on cask interior temperatures. See Section A3.3.2.2.4.1.1 for discussion.

35$,5,(,6/$1',1'(3(1'(1763(17)8(/6725$*(,167$//$7,21 6$)(7<$1$/<6,65(3257

Revision: 13 3D View Front View Side View FIGURE A3.3-21 STORAGE ARRAY MODEL FOR TN-40HT CASKS Insert New Figure A3.3-21a after this figure (on new page)

TN-40HT Cask Soil D* ---** ir

r,* ----* ~

Concrete thk = 3'1 ------**--------**-----------*

72' 8 X 18'

FIGURE A3.3-21A CFD MODEL FOR THE SOUTHEAST ISFSI PAD EXPANSION Dimensions for CFD Model CFD Model Temperature Distribution Results for Two Sets of ISFSI Pads

35$,5,(,6/$1',1'(3(1'(1763(17)8(/6725$*(,167$//$7,21 6$)(7<$1$/<6,65(3257

Revision: 17 Page A4.2-2 A4.2 STORAGE SITE The TN-40HT casks are designed is designed in accordance with the General Design Criteria set forth in 10CFR72(F) as discussed in Section 4.2. Additional details are provided below.

A4.2.1 STRUCTURES The discussion of the ISFSI structures in Section 4.2.1 is independent of cask design other than that the location of the cask drop accident analyses of the TN-40HT cask is in Section A8.2.8.

A4.2.1.1 STATIC ANALYSIS The ISFSI reinforced concrete cask pad analysis described in Section 4.2.1.1 was reviewed for the incorporation of the TN-40HT cask parameters and for increasing the allowed cask weight to a maximum of 250,000 lbs. The increase in cask weight input was reviewed in combination with a 1.5 inch decrease in the cask base diameter for the TN-40HT cask. The existing analysis utilizing the TN-40 input parameters contains considerable design margin. For example, as described in Section 4.2.1.1, the cask pad flexure strength margin indicates a safety factor of 2.14.

The review concluded that the increase to the maximum cask weight of 3.9% ((250 kip -

240.7 kip) / 240.7 kip) greater than used in the analysis and the 1.6% ((91 - 89.5) /

91) decrease in the cask base diameter will have a negligible effect on the adequacy determination of the cask pad analysis and design, and a more rigorous reanalysis is not warranted given the large margins that exist.

A4.2.1.2 DYNAMIC ANALYSIS The ISFSI concrete cask pad dynamic analysis described in Section 4.2.1.2 was reviewed for the incorporation of the TN-40HT cask parameters and for increasing the allowed cask weight to a maximum of 250,000 lbs. The increase in cask weight input was reviewed in combination with a 1.5 in decrease in the cask base diameter for the TN-40HT cask.

As noted in Section 4.2.1.2, ultimate static stresses govern the design, and dynamic seismic load combinations need not be further considered for the reinforced concrete and acceptable bearing stress design.

Replace with Insert S-5 See Insert S-6

Insert S-5 for page A4.2-2:

The discussion of the two original ISFSI pads in Section 4.2.1 is independent of cask design.

Likewise, the discussion of the ISFSI expansion pad in this section is independent of cask design. The location of the cask drop accident analyses of the TN-40HT cask applicable to all three pads is in Section A8.2.8.

ISFSI Expansion The primary function of the ISFSI expansion concrete pad is to provide a uniform level surface for storing the casks. The minimum pad elevation criterion has been set at 693 ft.-0 in. msl to preclude immersion of the cask seals during the probable maximum flood. The actual pad minimum elevation is 694 ft.-1 in. The southeast pad is slightly wider (4 ft. total) than the original pads. The gravel areas around the pads are compacted to allow for movement and positioning of the transport vehicle and tow vehicle. The subgrade preparation regimen (e.g., design of the mudmat foundation, use of compacted structural fill) for the southeast pad is the same as for the original pads.

The design of the southeast ISFSI pad used the guidance in NUREG-1536, Revision 1, Standard Review Plan for Spent Fuel Dry Storage Systems at a General License Facility (Reference 24), for the design load requirements of the concrete pad. Note that an additional load combination is also considered to check overturning and sliding for the flooding condition so that the design load combinations for the new ISFSI pad are also consistent with the design requirements for the original ISFSI pads, discussed in Section 4.2.1. In addition, the computer program SAFE (Reference 25), was used to perform the finite element analysis for the static analysis used to evaluate the design of the southeast ISFSI pad. The analysis was performed to verify that the strength of the pad was adequate to prevent unacceptable cracking or differential settlement and that the casks would not tip under design loads.

The original ISFSI pads were designed for a minimum concrete compressive strength of 3,000 psi at 28 days in accordance with ACI 349-85, and the 1990 supplement. The cask drop analysis for the TN-40HT cask design is based on a maximum compressive strength of 4,000 psi. The southeast ISFSI expansion pad design is based on the requirements in ACI 349-13, consistent with the guidance in NRC NUREG-1536, Revision 1. Note that later editions of ACI 349 (beyond ACI 349-85) required a higher minimum compressive strength

(> 4,000 psi) to meet freeze-thaw and durability requirements. Therefore, for the design of the southeast ISFSI pad, an exception is taken to the code provision requiring 4,500 psi minimum compressive strength to meet durability requirements so that the specified compression strength of the southeast ISFSI pad is 3,000 to 4,000 psi. Thus, the pad will represent a target of similar or lesser stiffness than the original ISFSI pads so that the existing cask drop analysis remains valid for the southeast ISFSI pad.

Sliding and overturning of casks is not reevaluated for the southeast pad, except for seismic loads, because hydrological loads (i.e., design basis flooding) and accident loads (i.e., the design basis munitions barge explosion) are enveloped by the tornado wind load. The tornado wind load and missile impact analysis in this addendum remains applicable (i.e., the coefficient of friction for the southeast pad is the same as for the original pads). The effect of seismic loads associated with the design basis safe shutdown earthquake (SSE) was evaluated because the dynamic analysis is performed using a different method which results in the development of new seismic loads (see Section A4.2.1.2).

Insert S-6 for page A4.2-2:

ISFSI Expansion As discussed in Section A4.2.1, the southeast ISFSI pad expansion pad design is based on the requirements in ACI 349-13, consistent with the guidance in NRC NUREG-1536, Revision 1, Standard Review Plan for Spent Fuel Dry Storage Systems at a General License Facility (Reference 24). The static analysis of the ISFSI expansion pad was performed using the SAFE computer program (Reference 25). The SAFE program was specifically developed for performing finite element analysis of slabs and beams. The TN-40HT cask parameters were used in the analysis for the southeast pad. The design model consists of slab elements supported by subgrade springs. The slab elements are modeled as four-node, isotropic, rectangular thick-plate elements that combine membrane and plate-bending behavior. The finite element mesh is defined to have maximum dimensions of 2ft. x 2ft. and is automatically generated by SAFE. The storage casks are not explicitly modeled in the SAFE design model.

Vertical forces and overturning moments induced by the casks are calculated and applied directly as vertical pressures to the concrete pad. Several cask loading conditions were evaluated.

The analysis concluded that the southeast pad is acceptable for its design loading. Additionally, the cask drop criterion (i.e., specified compression strength of 3,000 to 4,000 psi) is met, the pad has no net uplift, and the pad stability is maintained for the maximum differential settlement.

35$,5,(,6/$1',1'(3(1'(1763(17)8(/6725$*(,167$//$7,21 6$)(7<$1$/<6,65(3257

Revision: 17 Page A4.2-3 The review of the TN-40HT cask input section properties affecting dynamic analysis relative to the TN-40 properties indicated that the seismic accelerations at the center of gravity of the casks would not change significantly, and given the conservatism in the dynamic analysis, a reanalysis is not warranted. Therefore, the dynamic stability of the TN-40HT cask was determined from the governing seismic accelerations established by the existing dynamic analysis utilizing five modes for the controlling single cask configuration.

The cask overturning moment resulting from the governing accelerations was compared to the restoring moment resulting from the TN-40HT parameters. The factor of safety is the ratio of the restoring moment to the overturning moment. The minimum factor of safety for overturning was calculated to be 1.35. The minimum factor of safety for sliding was calculated to be 1.14.

A4.2.2 STORAGE SITE LAYOUT The storage site layout described in Section 4.2.2 remains applicable with the use of the TN-40HT casks.

A4.2.3 STORAGE CASK DESCRIPTION This section summarizes the structural analysis of the TN-40HT cask. For purposes of structural analysis, the cask has been divided into four components: the cask body (consisting of containment vessel and gamma shield shell), the basket, the trunnions and the neutron shield outer shell.

A4.2.3.1 DESIGN BASIS A4.2.3.1.1 CASK BODY The cask body is described in Section A1. Drawings are included in Section A1.5. The containment boundary inner shell and bottom inner plate material is SA-203 Gr. E, and shell flange and lid outer plate is SA-350 Gr. LF3 or SA-203 Gr. E. The shield shell and bottom shield material is SA-266 CL 2 or SA-516 Gr. 70. The lid shield plate material is SA-105 or SA-516 Gr. 70.

The TN-40HT containment vessel is designed, fabricated, examined and tested in accordance with the requirements of Section III, Subsection NB of the ASME Code (Reference 1) to the maximum practical extent. Alternatives taken to the ASME code are specified in Section A3.5. The containment boundary consists of the inner shell and bottom inner plate, shell flange, lid outer plate, lid bolts, vent and drain cover plates and bolts, bolts and the inner portions of the lid seal and the two lid penetrations (vent and drain).

See Insert S-7

Insert S-7 for page A4.2-3:

ISFSI Expansion The effect of seismic loads associated with the design basis safe shutdown earthquake (SSE) was evaluated for the southeast ISFSI pad using input parameters for the TN-40HT casks. The dynamic analysis is performed using a different method than that used for the original pads, which resulted in the development of new seismic loads.

New SSE response spectra consistent acceleration input motions were generated in accordance with the guidance in NUREG-0800, Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants: LWR [Light Water Reactor] Edition, (SRP)

Section 3.7.1, Seismic Design Parameters, to be used in the soil structure interaction (SSI) analysis for the pad. Also, new SSE-induced strain-compatible shear modulus (shear wave velocity) and damping values at various soil depths are determined, using SHAKE2000 (Reference 26), in accordance with the guidance in SRP Section 3.7.2, Seismic System Analysis, for use in the SSI analysis. To provide for the dynamic analysis of the pad, a calculation was developed to evaluate the seismic stability of free-standing casks placed on the pad for the SSE. The calculation also evaluates the structure-soil-structure interaction (SSSI) effects of the southeast pad on the original eastern pad. Linear SSI analyses are performed using the SASSI2010 program (Reference 27) and the SSSI is performed using results from the Response Spectrum Generator (RSG) program (Reference 28).

The dynamic analysis determined that the design of the southeast pad is acceptable and concluded that:

(1) The casks do not slide or overturn during an SSE; (2) The pad does not slide relative to the soil during SSE; and, (3) The SSSI effects between the southeast pad and original pads are insignificant.

35$,5,(,6/$1',1'(3(1'(1763(17)8(/6725$*(,167$//$7,21 6$)(7<$1$/<6,65(3257

Revision: 13 Page A4.7-2 13.

NUREG 1864 A Pilot Probabilistic Risk Assessment of a Dry Cask Storage System at a Nuclear Power Plant.

14.

U.S. NRC, Regulatory Guide 1.99, Rev. 2, Radiation Embrittlement of Reactor Vessel Materials, 1988.

15.

T Sanders et al., A Method for Determining the Spent-Fuel Contribution to Transport Cask Containment Requirements, Sandia Report SAND90-2406, Sandia National Laboratories, Albuquerque, NM, 1992.

16.

UCID - 21246, Dynamic Impact Effects on Spent Fuel Assemblies, Lawrence Livermore National Laboratory, October 20, 1987.

17.

K. J. Geelhood and C. E. Beyer, PNNL Stress/Strain Correlation for Zircaloy, March 2005 (summarized in Mechanical Properties of Irradiated Zircaloy, Transactions of the American Nuclear Society, pp 707-708, November 2005).

18.

LS-DYNA Keyword Users Manual, Volumes 1 & 2, Version 9.71s, Rev.

7600.398 August 17, 2006, Livermore Software Technology Corporation.

19.

L. F. Van Swam, A. A. Strasser, J. D. Cook, and J. M. Burger, Behavior of Zircaloy-4 and Zirconium Linear Zircaloy-4 Cladding at High Burnup, Proceedings of the1997 International Topical Meeting on LWR Fuel Performance, Portland, Oregon March 2-6, 1997.

20.

SCALE: A Modular Code System for Performing Standardized Computer Analyses for Licensing Evaluation, Vols. I-III, NUREG/CR-0200, Rev. 5 (ORNL/NUREG/CSD-2/R5), March 1997 (Standard Composition Library, Table M8.2.4).

21.

NUREG-612 Control of Heavy Loads at Nuclear Power Plants, July 1980 22.

Letter, Ashok Thadani (NRC) to S. R. Tritch (Westinghouse), Acceptance for Referencing of Topical Report WCAP-12610 Vantage+ Fuel Assembly Reference Core Report (TAC No. 77258) July 1, 1991.

23.

Siegmann, Eric R., J. Kevin McCoy, Robert Howard, Cladding Evaluation in the Yucca Mountain Repository Performance Assessment, Material Research Society Symp. Proc. Vol. 608, 2000.

See Insert S-8

Insert S-8 for page A4.7-2:

24. NUREG-1536, Revision 1, Standard Review Plan for Spent Fuel Dry Storage Systems at a General License Facility, July 2010.
25. SAFE, Version 12.3.1, Computers & Structures, Inc. (Sargent & Lundy, LLC (S&L) Program No. 03.7.241-12.3.1).
26. SHAKE2000, Version 9.95 (S&L Program No. 03.7.402-9.95)
27. SASSI2010, Version 1.0 (S&L Program No. 03.7.316-1.0-250USER-M01)
28. Response Spectrum Generator (RSG), Version 2.0 (S&L Program No. 03.7.414-2.0)

35$,5,(,6/$1',1'(3(1'(1763(17)8(/6725$*(,167$//$7,21 6$)(7<$1$/<6,65(3257

Revision: 17 Page A7.5-1 A7.5 OFFSITE COLLECTIVE DOSE ASSESSMENT Figure 1.2-1 illustrates the Prairie Island Nuclear Generating Plant site boundary, which is also the boundary of the exclusion area as defined in 10CFR100.3. This exclusion area corresponds to the controlled area for the ISFSI as defined in 10CFR72.3.

In calculating the offsite collective dose, the entire permanent population within a 2 mile radius of the plant was conservatively taken to be at the location of the residence subject to the highest exposure, i.e. 0.45 miles NW of the ISFSI. In addition to the permanent population, there is a large transient population of persons employed at or visitors to the Treasure Island Hotel and Casino that is located within a 2 mile radius of the plant. For these calculations it is assumed that this entire transient population is located 0.8 miles from the ISFSI. The estimates of the population (both permanent and transient) within the 2 mile radius were taken from the Prairie Island Nuclear Generating Plants evacuation time study (Reference 6). A description of the off-site locations considered in this evaluation, the relevant population data, distances and occupancy times are shown in Table A7.5-1.

The dose rate resulting from cask storage at the ISFSI as a function of distance is given in Table A7A.7-2. For a distance of 0.45 mile (724 meters) in the corner direction, the total dose rate is 2.20 E-3 rem/year. This is the annual exposure at the nearest resident location.

Table A7.5-2 shows the total dose rates from the ISFSI at each of the assumed off-site locations. In addition, Table A7.5-2 also contains the information summarized in Table A7.5-1. For conservatism, the dose rates calculated at a distance of 1004 m from the north-south face of the ISFSI are utilized to determine the off-site exposures at distances greater than 0.8 miles (1280 m).

Table A7.5-2 summarizes the calculated total doses to the off-site population within a 2-mile radius due to the ISFSI operation. The total collective off-site dose is calculated to be 2.21 person-rem.

01441968 3.07 3.19 A7.5-2

  • Note that, for the purposes of demonstrating compliance with the requirements of 10 CFR 72.104(a), 40 CFR 190.10(a), and 10 CFR 20.1301(a), a more conservative value is calculated, including the dose contribution from other sources such as planned plant discharges, as discussed in Section A7A.7.2.

_P

- TI

- b

35$,5,(,6/$1',1'(3(1'(1763(17)8(/6725$*(,167$//$7,21 6$)(7<$1$/<6,65(3257

Revision: 13 TABLE A7.4-3 STATION PERSONAL LOCATION AND DOSE RATES Location Location Distance (Feet From Center ISFSI)

Full Time Outage Dose

Rate, mrem/hr 1

34 OCA Gatehouse (D-2) 978 2

0 2.36e-2 2

22 Receiving Warehouse (D-5) 55 13 P1ex Project Office (D-5)

A 4 P1ex Project Office (D-5) 953 30 0

2.55e-2 3

24 NPD Building (E-6) 33 NPD Annex Building (E-5)

Quality Assurance Modular Office (E-5) 1016 60 1

2.08e-2 4

42 Fabrication Shop (C-5) 25 Steam Generator Mock up Building (C-5) 48 Fabrication Shop (D-5) 1381 2

45 5.19e-3 5

30 Warehouse (C-5) 31 Multiuse Warehouse (C-5) 21 Warehouse -8 (C-6) 1650 0

2 2.07e-3 6

12 Substation, SBO Structures (B-6) 2236 0

2 3.60e-4 7

23 New Administration Building (D-6) 6 Security Building (D-6) 1496 287 25 2.93e-3 8

4 Turbine Building (D-7) 28 Warehouse -2 (E-7) 3 Auxiliary Building (E-7) 13 New Service Building (D-8) 11 D5/D6 DG Building (D-7) 79 Security DG Building (D-7) 1650 180 192 2.07e-3 9

Outage Trailers (E-7) 1322 5

40 6.39e-3 10 60 Fabrication Shop (E-7) 29 Main Plant Warehouse (E-7) 66 Maintenance Storage Building (E-7) 1557 23 45 2.59e-3 11 20 Environmental Lab (B-9) 2534 2

0 1.58e-4 12 Training Center 905 49 0

2.91e-2 13 38 Old Administration Building (D-7) 71 Administration Building Addition (D-

7) 1745 68 0

1.53e-3 14 13 New Service Building (D-8) 1905 9

0 9.36e-4 Personnel Replace with Insert R-1

~

/

/

~

/

~

/

~

V

/

~ /

" / '

/'

I'\\..

~

/

~

/

" ~

/

/

/

~

/

Insert R-1 for replacement of Table A7.4-3:

Location #

Location Distance (Feet From Center ISFSI)

Full Time (Personnel)

Outage (Personnel)

Dose Rate (mrem/hr) 1 34 OCA Gatehouse (D-2) 978 2

0 3.41E-02 2

22 Receiving Warehouse (D-5) 953 30 0

3.69E-02 55 13 P1ex Project Office (D-5)

A 4 P1ex Project Office (D-5) 3 24 NPD Building (E-6) 1016 60 1

3.01E-02 33 NPD Annex Building (E-5)

Quality Assurance Modular Office (E-5) 4 42 Fabrication Shop (C-5) 1381 2

45 7.50E-03 25 Steam Generator Mock up Building (C-5) 48 Fabrication Shop (D-5) 5 30 Warehouse (C-5) 1650 0

2 2.99E-03 31 Multiuse Warehouse (C-5) 21 Warehouse -8 (C-6) 6 12 Substation, SBO Structures (B-6) 2236 0

2 5.20E-04 7

23 New Administration Building (D-6) 1496 287 25 4.24E-03 6 Security Building (D-6) 8 4 Turbine Building (D-7) 1650 180 192 2.99E-03 28 Warehouse -2 (E-7) 3 Auxiliary Building (E-7) 13 New Service Building (D-8) 11 D5/D6 DG Building (D-7) 79 Security DG Building (D-7) 9 Outage Trailers (E-7) 1322 5

40 9.24E-03 10 60 Fabrication Shop (E-7) 1557 23 45 3.74E-03 29 Main Plant Warehouse (E-7) 66 Maintenance Storage Building (E-7) 11 20 Environmental Lab (B-9) 2534 2

0 2.28E-04 12 Training Center 905 49 0

4.21E-02 13 38 Old Administration Building (D-7) 1745 68 0

2.21E-03 71 Administration Building Addition (D-7) 14 13 New Service Building (D-8) 1905 9

0 1.35E-03

35$,5,(,6/$1',1'(3(1'(1763(17)8(/6725$*(,167$//$7,21 6$)(7<$1$/<6,65(3257

Revision: 13 TABLE A7.4-4 STATION PERSONAL COLLECTIVE DOSE Location Location Distance (Feet From Center ISFSI)

Full Time

  • Outage **

Total

Exposure, person-rem 1

34 OCA Gatehouse (D-2) 978 0.12 0

0.12 2

22 Receiving Warehouse (D-5) 55 13 P1ex Project Office (D-5)

A 4 P1ex Project Office (D-5) 953 1.91 0

1.91 3

24 NPD Building (E-6) 33 NPD Annex Building (E-5)

Quality Assurance Modular Office (E-

5) 1016 3.12 1.12e-2 3.13 4

42 Fabrication Shop (C-5) 25 Steam Generator Mock up Building (C-5) 48 Fabrication Shop (D-5) 1381 0.03 0.13 0.15 5

30 Warehouse (C-5) 31 Multiuse Warehouse (C-5) 21 Warehouse -8 (C-6) 1650 0

0.00 2.23e-3 6

12 Substation, SBO Structures (B-6) 2236 0

3.89e-4 3.89e-4 7

23 New Administration Building (D-6) 6 Security Building (D-6) 1496 2.10 0.04 2.14 8

4 Turbine Building (D-7) 28 Warehouse -2 (E-7) 3 Auxiliary Building (E-7) 13 New Service Building (D-8) 11 D5/D6 DG Building (D-7) 79 Security DG Building (D-7) 1650 0.93 0.21 1.14 9

Outage Trailers (E-7) 1322 0.08 0.14 0.22 10 60 Fabrication Shop (E-7) 29 Main Plant Warehouse (E-7) 66 Maintenance Storage Building (E-7) 1557 0.15 0.06 0.21 11 20 Environmental Lab (B-9) 2534 0.00 0

7.91e-4 12 Training Center 905 3.57 0

3.57 13 38 Old Administration Building (D-7) 71 Administration Building Addition (D-

7) 1745 0.26 0

0.26 14 13 New Service Building (D-8) 1905 0.02 0

0.02 Total 12.28 0.59 12.88

  • For full time employees, assume 2500 hour0.0289 days <br />0.694 hours <br />0.00413 weeks <br />9.5125e-4 months <br />s/year.
    • For outage employees, assume 540 hour0.00625 days <br />0.15 hours <br />8.928571e-4 weeks <br />2.0547e-4 months <br />s/year.

Personnel Replace with Insert R-2

~

/

V

~

/

~

/

/

~

V

/

~ /

/

/ '

~

I'\\.

/

/

" ~

/

'\\,.

/

'\\,.

/

~~

/

/

/

/

Insert R-2 for replacement of Table A7.4-4:

Location #

Location Distance (Feet From Center ISFSI)

Full Time (person-rem)

Outage (person-rem)

Total Exposure (person-rem) 1 34 OCA Gatehouse (D-2) 978 1.73E-01 0.00E+00 1.73E-01 2

22 Receiving Warehouse (D-5) 953 2.76E+00 0.00E+00 2.76E+00 55 13 P1ex Project Office (D-5)

A 4 P1ex Project Office (D-5) 3 24 NPD Building (E-6) 1016 4.51E+00 1.62E-02 4.53E+00 33 NPD Annex Building (E-5)

Quality Assurance Modular Office (E-5) 4 42 Fabrication Shop (C-5) 1381 4.34E-02 1.88E-01 2.31E-01 25 Steam Generator Mock up Building (C-5) 48 Fabrication Shop (D-5) 5 30 Warehouse (C-5) 1650 0.00E+00 3.22E-03 3.22E-03 31 Multiuse Warehouse (C-5) 21 Warehouse -8 (C-6) 6 12 Substation, SBO Structures (B-6) 2236 0.00E+00 5.62E-04 5.62E-04 7

23 New Administration Building (D-6) 1496 3.04E+00 5.78E-02 3.09E+00 6 Security Building (D-6) 8 4 Turbine Building (D-7) 1650 1.34E+00 3.04E-01 1.65E+00 28 Warehouse -2 (E-7) 3 Auxiliary Building (E-7) 13 New Service Building (D-8) 11 D5/D6 DG Building (D-7) 79 Security DG Building (D-7) 9 Outage Trailers (E-7) 1322 1.16E-01 2.02E-01 3.18E-01 10 60 Fabrication Shop (E-7) 1557 2.17E-01 8.67E-02 3.04E-01 29 Main Plant Warehouse (E-7) 66 Maintenance Storage Building (E-7) 11 20 Environmental Lab (B-9) 2534 1.14E-03 0.00E+00 1.14E-03 12 Training Center 905 5.16E+00 0.00E+00 5.16E+00 13 38 Old Administration Building (D-7) 1745 3.76E-01 0.00E+00 3.76E-01 71 Administration Building Addition (D-7) 14 13 New Service Building (D-8) 1905 2.89E-02 0.00E+00 2.89E-02 Total 1.78E+01 8.58E-01 1.86E+01

35$,5,(,6/$1',1'(3(1'(1763(17)8(/6725$*(,167$//$7,21 6$)(7<$1$/<6,65(3257

Revision: 17 TABLE A7.5-2 OFFSITE POPULATION: DOSE RATES AND COLLECTIVE DOSE Offsite Population Description Distance Occupancy times Population Dose

Rate, mrem/hr Collective
Exposure, person-rem Permanent*

population within 2 mile radius 2 mile radius

>0.45 miles 8760 398 2.42e-4 0.84 Transient Employee Population 2 mile -PI community center, government center, and clinic 0.8 mile 2000 80 2.64e-5 4.22e-3 2 mile -Employees at Treasure Island Casino 0.8 mile 8760 435 2.64e-5 0.10 Transient recreational population 2 mile -Treasure Island Casino 0.8 mile 8760 5400 2.64e-5 1.25 Marina and RV Park 2 mile -PI community center, government center, and clinic 0.8 mile 1160 450 2.64e-5 1.38e-2 Total Collective Within 2 Mile 2.21 01441968 Replace with Insert R-3

Insert R-3 for replacement of Table A7.5-2:

Offsite Population Description Distance Occupancy Times Population Dose Rate (mrem/hr)

Collective Exposure (person-rem)

Permanent Population Within 2 Mile Radius 2 mile - radius

> 0.45 mile 8760 398 3.50E-04 1.21E+00 Transient Employee Population 2 mile - PI community center, government center, and clinic 0.8 mile 2000 80 3.82E-05 6.10E-03 2 mile - Employees at Treasure Island Casino 0.8 mile 8760 435 3.82E-05 1.45E-01 Transient Recreational Population 2 mile - Treasure Island Casino 0.8 mile 8760 5400 3.82E-05 1.81E+00 Marina and RV Park 2 mile - PI community center, government center, and clinic 0.8 mile 1160 450 3.82E-05 1.99E-02 Total Collective Within 2 Mile 3.19E+00

35$,5,(,6/$1',1'(3(1'(1763(17)8(/6725$*(,167$//$7,21 6$)(7<$1$/<6,65(3257

Revision: 13 Page A7A.2-1 A7A.2 DISCUSSION AND

SUMMARY

OF RESULTS The shielding evaluation presented in this section is performed utilizing as a design basis the source terms from the14x14 Westinghouse standard fuel assembly with fuel inserts. This fuel assembly is bounding because it contains the highest mass of fuel among the candidate fuel assemblies. 

All shielding calculations are performed using the computer code MCNP (Reference 1) which uses a 3-dimensional Monte Carlo method. MCNP is a general-purpose Monte Carlo N-Particle code that can be used for neutron, photon, electron, or coupled neutron/photon/electron transport. The code treats an arbitrary three-dimensional configuration of materials in geometric cells bounded by first-and second-degree surfaces and some special fourth-degree surfaces. Point-wise (continuous energy) cross-section data are used. The MCNP code is selected because of its ability to handle thick, multi-layered shields as in the TN-40HT cask body using 3-D geometry. 

For neutrons, all reactions given in a particular cross-section evaluation are accounted for in the cross section set. For photons, the code takes account of incoherent and coherent scattering, the possibility of fluorescent emission after photoelectric absorption, absorption in pair production with local emission of annihilation radiation, and bremsstrahlung. Important standard features that make MCNP very versatile and easy to use include a powerful general source; an extensive collection of cross-section data; and an extensive collection of variance reduction techniques that can be employed to track particles through very complex deep penetration problems. Mesh tallies capabilities were utilized in calculating dose rates distributed over and around the surface of the TN-40HT cask.

Normal and off-normal conditions are modeled with the TN-40HT cask intact. Average dose rates on the side, top and bottom of the TN-40HT cask are calculated. Maximum dose rates are also calculated above and below the radial neutron shield.

Accident conditions assume radially the neutron shield and steel outer shell are removed and axially the polypropylene disk and protective cover are removed. This evaluation bounds the accident conditions in Section A8.

The expected dose rates (for normal, off-normal, and accident conditions) from the TN-40HT cask are provided in Table A7A.2-1. The dose point locations are illustrated in Figure A7A.2-1.

The total (direct + skyshine) dose rates as a function of distance from the cask are presented in Table A7A.2-2.

The total ISFSI dose rate (from 48 casks all containing design basis fuel at the time of initial loading) as a function of distance from each location (N/S side, E/W side, or corner) is summarized in Table A7A.7-2.

64 p

35$,5,(,6/$1',1'(3(1'(1763(17)8(/6725$*(,167$//$7,21 6$)(7<$1$/<6,65(3257

Revision: 13 Page A7A.7-1 A7A.7 OFFSITE DOSE RATE CALCULATIONS This Section evaluates off-site dose rates assuming the ISFSI consists of two (2) 2x12 array of TN-40HT casks, loaded in sets of four casks every two years, each loaded with design-basis fuel at the time of initial loading (i.e. total of 48 casks and credit for decay while the casks are on the ISFSI pads). This conservatively bounds the currently allowed storage of 48 casks and bounds operation with a mixture of TN-40 and TN-40HT casks. The ISFSI layout used in this evaluation is shown in Figure A7A.7-1.

This evaluation determines the neutron and gamma-ray off-site dose rates including skyshine in the vicinity of the ISFSI. It provides results for distances ranging from 10 to 1,000 meters from the front, side and corner of the arrays. A co-ordinate transformation of these results is performed so that they may be reported as a distance from a common point, i.e., the center of the ISFSI.

The Monte Carlo computer code MCNP (Reference 1) calculates the dose rates at the specified locations around the array of casks. An MCNP Array method is utilized to evaluate the dose rate as a function of distance from the ISFSI.

A7A.7.1 MCNP ARRAY METHOD - METHODOLOGY, MODEL AND ASSUMPTIONS The ISFSI layout as illustrated in Figure A7A.7-1 is explicitly modeled in MCNP using advanced MCNP geometry. The gamma and neutron dose rates are determined as a function of distance from the ISFSI. All the doses are determined using F5 detector tallies.

The ISFSI array MCNP model consists of a two 2x12 arrays of TN40-HT casks. The cask array is modeled using advanced MCNP geometry to represent the ISFSI as shown in Figure A7A.7-1. Source specification is consistent with the loading scheme where four casks are loaded every two years. Due to the symmetry of the layout of the cask array and in the loading schedule, sources are only specified for the north-west row of casks (even-numbered casks 2 through 24 from Figure A7A.7-1). Even though, sources are not specified in the remaining 36 casks, the shielding configurations are identical and ensure that the resulting dose rate distribution around the ISFSI is symmetric. Tallies are constructed from small, spherical, F5 detectors providing for variance reduction capabilities. These detectors are positioned all around the ISFSI (all sides and corner locations) to determine the dose rates as a result of the source symmetry. These detector locations are shown in Table A7A.7-1.

Add Insert R-10 Add Insert R-11 q

Insert R-10 for page A7A.7-1:

This Section also evaluates off-site dose rates assuming the southeast ISFSI pad consists of one (1) 2 x 8 array of TN-40HT casks, loaded in sets of four casks every two years, each loaded with design-basis fuel at the time of initial loading (i.e., total of 16 casks and credit for decay while the casks are on the ISFSI pads). The southeast ISFSI pad location is conservatively modeled as being in the same location as the original ISFSI pad (although the southeast ISFSI pad actual location is farther from the location-specific dose points). This conservatively bounds the allowed storage on the southeast ISFSI pad of 16 casks and bounds operation with a mixture of TN-40 and TN-40HT casks.

Insert R-11 for page A7A.7-1:

These results are used to determine the total normal operation radiation dose values at the nearest site boundary and at the nearest resident to show compliance with the requirements of 10 CFR 72.104(a),

40 CFR 190.10(a), and 10 CFR 20.1301(a).

35$,5,(,6/$1',1'(3(1'(1763(17)8(/6725$*(,167$//$7,21 6$)(7<$1$/<6,65(3257

Revision: 13 Page A7A.7-3 The assumptions for the MCNP methodology are summarized below.

x Due to symmetry of the cask loading configurations, the source specification is simplified and considered only for 12 of the 48 casks while the detectors are positioned to obtain the results as a result of this simplified source specification.

x The "universe" is a sphere surrounding the ISFSI. The radius of this sphere (r=5.0 kilometers) is more than 20 mean free paths for neutrons and more than 20 mean free paths for gammas in energy groups that contribute the most to the gamma radiation dose rates. This ensures that the model is of a sufficient size to include all interactions affecting the dose rate at the detector locations.

x Detectors located at distances less than or equal to 45 meters are within the ISFSI berm perimeter. Dose rates points at larger distances are behind the berm. It is likely that the dose rates beyond the berm perimeter are almost entirely due to skyshine component.

x Dose rates include contribution due to primary gamma and neutron sources as well as due to the secondary gamma radiation from (n,g) interactions.

A7A.7.2 MCNP ARRAY METHOD - DOSE RATE AS A FUNCTION OF DISTANCE The MCNP results provide the dose rate as a function of distance at all the locations (including sides and corner) around the ISFSI. The total and skyshine dose rate results for the N/S sides, E/W sides and the corners are shown in Table A7A.7-2. The skyshine doses are shown in Table A7A.7-3 only for comparison. Due to presence of the ISFSI berm, it is expected that the dose rates at distances greater than 100m are dominated by the skyshine component and these results serve to demonstrate this assertion. Co-ordinate transformation is performed such that the results reported in Table A7A.7-2 are based on the distance from the center of the ISFSI.

Add Insert R-14

Insert R-14 for page A7A.7-3:

The ISFSI dose rate as a function of distance results and the dose contribution due to other uranium fuel cycle operations conducted on the site are used to determine the total normal operation radiation dose values at the nearest site boundary and at the nearest resident to show compliance with the requirements of 10 CFR 72.104(a), 40 CFR 190.10(a), and 10 CFR 20.1301(a). The dose at the nearest site boundary due to other uranium fuel cycle operations is assumed to be negligible when compared to the radiation level associated with the ISFSI. The dose at the nearest resident due to other uranium fuel cycle operations is obtained from the 2017 Annual Radioactive Effluent Report. The dose at the nearest resident due to other uranium fuel cycle operations is 1.50E-02 mrem/yr.

Comparisons between normal operation radiation dose values and the dose limits of 10 CFR 72.104(a),

40 CFR 190.10(a), and 10 CFR 20.1301(a) are presented below.

10 CFR 72.104(a) and 40 CFR 190.10(a) Annual Dose (Nearest Resident)

Source Total (mrem/yr)

Criteria (mrem/yr)

Margin (mrem/yr)

Original ISFSI (Fully Loaded) 3.39 25 21.61 Southeast ISFSI (16 Casks)

Planned Discharges 10 CFR 20.1301(a)(1) Annual Dose (Nearest Resident)

Source Total (rem/yr)

Criteria (rem/yr)

Margin (rem/yr)

Licensed Operation 0.00339 0.1 0.09661 10 CFR 20.1301(a)(2) Dose Rate (Site Boundary)

Source Total (rem/hr)

Criteria (rem/hr)

Margin (rem/hr)

Original ISFSI (Fully Loaded) 0.0004 0.002 0.0016 Southeast ISFSI (16 Casks)

Other Sources The calculated dose values at the nearest site boundary and at the nearest resident meet the acceptance criteria of 10 CFR 72.104(a), 40 CFR 190.10(a), and 10 CFR 20.1301(a). Note that this analysis does not establish any restrictions on cask placement. In other words, the analysis bounds any distribution of 64 TN-40HT (or TN-40) casks across the three ISFSI pads (e.g., 48 casks on the original ISFSI pads and 16 casks on the southeast pad, or 24 casks on the southeast pad and 40 casks on the original pads).

35$,5,(,6/$1',1'(3(1'(1763(17)8(/6725$*(,167$//$7,21 6$)(7<$1$/<6,65(3257

Revision: 13 TABLE A7A.7-2 DOSE RATES AS A FUNCTION OF DISTANCE FROM THE ISFSI (PAGE 1 OF 2)

From the ISFSI "North\\South" Faces Distance from the ISFSI Center (meters)

Gamma Radiation Neutron Radiation

Total, Gamma+Neutron, Radiation Dose Rate
Value, mrem/hr Dose Rate Relative Error Dose Rate
Value, mrem/hr Dose Rate Relative Error Dose Rate
Value, mrem/hr Dose Rate Relative Error 4.03 5.51 0.02 6.94 0.04 12.45 0.02 14.03 3.57 0.01 4.84 0.03 8.42 0.02 49.03 1.09 0.01 1.56 0.02 2.65 0.02 104.03 0.06 0.01 0.22 0.02 0.28 0.02 204.03 0.02 0.01 0.04 0.03 0.06 0.02 304.03 0.005 0.01 0.010 0.04 0.015 0.02 404.03 0.002 0.02 0.003 0.05 0.005 0.03 504.03 6.29e-4 0.03 9.06e-4 0.05 1.53e-3 0.03 604.03 2.52e-4 0.03 3.24e-4 0.09 5.77e-4 0.05 704.03 1.42e-4 0.18 1.30e-4 0.11 2.72e-4 0.11 804.03 6.13e-5 0.07 6.02e-5 0.24 1.22e-4 0.12 904.03 2.80e-5 0.06 1.95e-5 0.12 4.75e-5 0.06 1004.03 1.72e-5 0.09 9.21e-6 0.15 2.64e-5 0.08 From the ISFSI "East\\West" Faces Distance from the ISFSI Center (meters)

Gamma Radiation Neutron Radiation

Total, Gamma+Neutron, Radiation Dose Rate
Value, mrem/hr Dose Rate Relative Error Dose Rate
Value, mrem/hr Dose Rate Relative Error Dose Rate
Value, mrem/hr Dose Rate Relative Error 70.47 33.29 0.03 28.73 0.04 62.03 0.02 80.47 2.77 0.02 4.43 0.04 7.20 0.03 115.47 0.06 0.01 0.25 0.02 0.30 0.02 170.47 0.03 0.01 0.10 0.02 0.13 0.02 270.47 0.01 0.02 0.02 0.02 0.03 0.02 370.47 0.002 0.02 0.005 0.05 0.008 0.04 470.47 0.001 0.03 0.002 0.06 0.002 0.04 570.47 3.06e-4 0.03 4.77e-4 0.06 7.83e-4 0.04 670.47 1.25e-4 0.03 2.33e-4 0.12 3.58e-4 0.08 770.47 5.77e-5 0.05 8.38e-5 0.14 1.41e-4 0.09 870.47 2.71e-5 0.04 2.43e-5 0.12 5.14e-5 0.06 970.47 1.48e-5 0.06 1.15e-5 0.27 2.62e-5 0.12 1070.47 8.36e-6 0.08 4.44e-6 0.11 1.28e-5 0.06 Replace with Insert R-4 Replace with Insert R-5

~

/

/

~

V

/

/

V

/

~

/ "'

/

I'--.

/

V

/

/

/

"r---..

/

/

~

/

~

/

/

/

//

~

'-....../

/~

/

/

/

/

~

/ /

/

/

Insert R-4 for replacement of Table A7A.7-2, Page 1 of 2, From the ISFSI North\\South Faces:

Distance from ISFSI Face (meters)

Distance from ISFSI Center (meters)

Gamma Radiation Dose Rate (mrem/hr)

Neutron Radiation Dose Rate (mrem/hr)

Total Dose Rate (mrem/hr) 0 4.03 7.72E+00 9.94E+00 1.77E+01 10 14.03 5.00E+00 6.93E+00 1.19E+01 45 49.03 1.53E+00 2.23E+00 3.76E+00 100 104.03 8.41E-02 3.15E-01 3.99E-01 200 204.03 2.80E-02 5.73E-02 8.53E-02 300 304.03 7.01E-03 1.43E-02 2.13E-02 400 404.03 2.80E-03 4.30E-03 7.10E-03 500 504.03 8.82E-04 1.30E-03 2.18E-03 600 604.03 3.53E-04 4.64E-04 8.17E-04 700 704.03 1.99E-04 1.86E-04 3.85E-04 800 804.03 8.59E-05 8.62E-05 1.72E-04 900 904.03 3.92E-05 2.79E-05 6.72E-05 1000 1004.03 2.41E-05 1.32E-05 3.73E-05 Insert R-5 for replacement of Table A7A.7-2, Page 1 of 2, From the ISFSI East\\West Faces:

Distance from ISFSI Face (meters)

Distance from ISFSI Center (meters)

Gamma Radiation Dose Rate (mrem/hr)

Neutron Radiation Dose Rate (mrem/hr)

Total Dose Rate (mrem/hr) 0 70.47 4.67E+01 4.11E+01 8.78E+01 10 80.47 3.88E+00 6.34E+00 1.02E+01 45 115.47 8.41E-02 3.58E-01 4.42E-01 100 170.47 4.21E-02 1.43E-01 1.85E-01 200 270.47 1.40E-02 2.86E-02 4.27E-02 300 370.47 2.80E-03 7.16E-03 9.96E-03 400 470.47 1.40E-03 2.86E-03 4.27E-03 500 570.47 4.29E-04 6.83E-04 1.11E-03 600 670.47 1.75E-04 3.34E-04 5.09E-04 700 770.47 8.09E-05 1.20E-04 2.01E-04 800 870.47 3.80E-05 3.48E-05 7.28E-05 900 970.47 2.07E-05 1.65E-05 3.72E-05 1000 1070.47 1.17E-05 6.36E-06 1.81E-05

35$,5,(,6/$1',1'(3(1'(1763(17)8(/6725$*(,167$//$7,21 6$)(7<$1$/<6,65(3257

Revision: 13 TABLE A7A.7-2 DOSE RATES AS A FUNCTION OF DISTANCE FROM THE ISFSI (PAGE 2 OF 2)

From ISFSI Corners Distance from the ISFSI Center (meters)

Gamma Radiation Neutron Radiation

Total, Gamma+Neutron, Radiation Dose Rate
Value, mrem/hr Dose Rate Relative Error Dose Rate
Value, mrem/hr Dose Rate Relative Error Dose Rate
Value, mrem/hr Dose Rate Relative Error 77.91 3.67 0.01 5.13 0.03 8.80 0.02 107.91 0.50 0.01 0.80 0.02 1.30 0.01 159.24 0.04 0.01 0.12 0.01 0.15 0.01 256.49 0.01 0.01 0.02 0.02 0.03 0.01 355.27 0.003 0.02 0.01 0.04 0.01 0.03 454.58 0.001 0.02 0.002 0.03 0.003 0.02 554.14 4.53e-4 0.02 6.67e-4 0.06 1.12e-3 0.04 653.84 1.94e-4 0.03 2.37e-4 0.07 4.31e-4 0.04 753.61 9.07e-5 0.04 8.48e-5 0.09 1.75e-4 0.05 853.44 4.36e-5 0.03 3.94e-5 0.14 8.30e-5 0.07 953.31 3.95e-5 0.38 1.17e-5 0.10 5.12e-5 0.29 1053.20 1.31e-5 0.04 5.59e-6 0.10 1.87e-5 0.04 Replace with Insert R-6

~

/

~

V

/

/

~ /

X V

/

/

/

~

/

V

/

/

Insert R-6 for replacement of Table A7A.7-2, Page 2 of 2, From the ISFSI Corners:

Distance from ISFSI Face (meters)

Distance from ISFSI Center (meters)

Gamma Radiation Dose Rate (mrem/hr)

Neutron Radiation Dose Rate (mrem/hr)

Total Dose Rate (mrem/hr) 10 77.91 5.14E+00 7.35E+00 1.25E+01 45 107.91 7.01E-01 1.15E+00 1.85E+00 100 159.24 5.61E-02 1.72E-01 2.28E-01 200 256.49 1.40E-02 2.86E-02 4.27E-02 300 355.27 4.21E-03 1.43E-02 1.85E-02 400 454.58 1.40E-03 2.86E-03 4.27E-03 500 554.14 6.35E-04 9.55E-04 1.59E-03 600 653.84 2.72E-04 3.39E-04 6.11E-04 700 753.61 1.27E-04 1.21E-04 2.49E-04 800 853.44 6.11E-05 5.64E-05 1.18E-04 900 953.31 5.54E-05 1.68E-05 7.21E-05 1000 1053.20 1.84E-05 8.00E-06 2.64E-05

35$,5,(,6/$1',1'(3(1'(1763(17)8(/6725$*(,167$//$7,21 6$)(7<$1$/<6,65(3257

Revision: 13 TABLE A7A.7-3 SKYSHINE DOSE RATES AS A FUNCTION OF DISTANCE FROM THE ISFSI (PAGE 1 OF 2)

From the ISFSI "North\\South" Faces Distance from the ISFSI Center (meters)

Gamma Radiation Neutron Radiation Total Skyshine, Gamma+Neutron, Radiation Dose Rate

Value, mrem/hr Dose Rate Relative Error Dose Rate
Value, mrem/hr Dose Rate Relative Error Dose Rate
Value, mrem/hr Dose Rate Relative Error 4.03 4.77 0.02 6.94 0.04 11.71 0.02 14.03 3.08 0.02 4.84 0.03 7.93 0.02 49.03 0.94 0.01 1.56 0.02 2.50 0.02 104.03 0.06 0.01 0.22 0.02 0.27 0.02 204.03 0.01 0.01 0.04 0.03 0.06 0.02 304.03 0.004 0.02 0.010 0.04 0.015 0.03 404.03 0.001 0.02 0.003 0.05 0.004 0.03 504.03 5.77e-4 0.04 9.06e-4 0.05 1.48e-3 0.03 604.03 2.27e-4 0.04 3.24e-4 0.09 5.51e-4 0.05 704.03 1.29e-4 0.20 1.30e-4 0.11 2.59e-4 0.11 804.03 5.48e-5 0.08 6.02e-5 0.24 1.15e-4 0.13 904.03 2.46e-5 0.06 1.95e-5 0.12 4.41e-5 0.06 1004.03 1.52e-5 0.11 9.21e-6 0.15 2.44e-5 0.09 From the ISFSI "East\\West" Faces Distance from the ISFSI Center (meters)

Gamma Radiation Neutron Radiation Total Skyshine, Gamma+Neutron, Radiation Dose Rate

Value, mrem/hr Dose Rate Relative Error Dose Rate
Value, mrem/hr Dose Rate Relative Error Dose Rate
Value, mrem/hr Dose Rate Relative Error 70.47 28.19 0.04 28.71 0.04 56.902 0.03 80.47 2.38 0.03 4.43 0.04 6.812 0.03 115.47 0.05 0.01 0.25 0.02 0.297 0.02 170.47 0.03 0.01 0.10 0.02 0.127 0.02 270.47 0.01 0.02 0.02 0.02 0.027 0.02 370.47 0.002 0.02 0.005 0.05 0.007 0.04 470.47 0.001 0.04 0.002 0.06 0.002 0.04 570.47 2.72e-4 0.03 4.77e-4 0.06 7.49e-4 0.04 670.47 1.10e-4 0.04 2.33e-4 0.12 3.43e-4 0.08 770.47 4.97e-5 0.06 8.38e-5 0.14 1.34e-4 0.09 870.47 2.32e-5 0.04 2.43e-5 0.12 4.75e-5 0.06 970.47 1.23e-5 0.07 1.15e-5 0.27 2.38e-5 0.13 1070.47 6.99e-6 0.09 4.44e-6 0.11 1.14e-5 0.07 Replace with Insert R-7 Replace with Insert R-8

~

/

v /

~

/

/

/

r-...

/

"./

I/

/

/

/

/

/

/

/

/

~

/

~

v /

/

/

,,,/ '

... "./

/

/

/

/

/

/

/

/

/

Insert R-7 for replacement of Table A7A.7-3, Page 1 of 2, From the ISFSI North\\South Faces:

Distance from ISFSI Face (meters)

Distance from ISFSI Center (meters)

Gamma Radiation Dose Rate (mrem/hr)

Neutron Radiation Dose Rate (mrem/hr)

Total Skyshine Dose Rate (mrem/hr) 0 4.03 6.69E+00 9.94E+00 1.66E+01 10 14.03 4.32E+00 6.93E+00 1.12E+01 45 49.03 1.32E+00 2.23E+00 3.55E+00 100 104.03 8.41E-02 3.15E-01 3.99E-01 200 204.03 1.40E-02 5.73E-02 7.13E-02 300 304.03 5.61E-03 1.43E-02 1.99E-02 400 404.03 1.40E-03 4.30E-03 5.70E-03 500 504.03 8.09E-04 1.30E-03 2.11E-03 600 604.03 3.18E-04 4.64E-04 7.82E-04 700 704.03 1.81E-04 1.86E-04 3.67E-04 800 804.03 7.68E-05 8.62E-05 1.63E-04 900 904.03 3.45E-05 2.79E-05 6.24E-05 1000 1004.03 2.13E-05 1.32E-05 3.45E-05 Insert R-8 for replacement of Table A7A.7-3, Page 1 of 2, From the ISFSI East\\West Faces:

Distance from ISFSI Face (meters)

Distance from ISFSI Center (meters)

Gamma Radiation Dose Rate (mrem/hr)

Neutron Radiation Dose Rate (mrem/hr)

Total Skyshine Dose Rate (mrem/hr) 0 70.47 3.95E+01 4.11E+01 8.06E+01 10 80.47 3.34E+00 6.34E+00 9.68E+00 45 115.47 7.01E-02 3.58E-01 4.28E-01 100 170.47 4.21E-02 1.43E-01 1.85E-01 200 270.47 1.40E-02 2.86E-02 4.27E-02 300 370.47 2.80E-03 7.16E-03 9.96E-03 400 470.47 1.40E-03 2.86E-03 4.27E-03 500 570.47 3.81E-04 6.83E-04 1.06E-03 600 670.47 1.54E-04 3.34E-04 4.88E-04 700 770.47 6.97E-05 1.20E-04 1.90E-04 800 870.47 3.25E-05 3.48E-05 6.73E-05 900 970.47 1.72E-05 1.65E-05 3.37E-05 1000 1070.47 9.80E-06 6.36E-06 1.62E-05

35$,5,(,6/$1',1'(3(1'(1763(17)8(/6725$*(,167$//$7,21 6$)(7<$1$/<6,65(3257

Revision: 13 TABLE A7A.7-3 SKYSHINE DOSE RATES AS A FUNCTION OF DISTANCE FROM THE ISFSI (PAGE 2 OF 2)

From ISFSI Corners Distance from the ISFSI Center (meters)

Gamma Radiation Neutron Radiation Total Skyshine, Gamma+Neutron, Radiation Dose Rate

Value, mrem/hr Dose Rate Relative Error Dose Rate
Value, mrem/hr Dose Rate Relative Error Dose Rate
Value, mrem/hr Dose Rate Relative Error 77.91 3.15 0.02 5.12 0.03 8.28 0.02 107.91 0.43 0.01 0.80 0.02 1.23 0.01 159.24 0.03 0.01 0.12 0.01 0.15 0.01 256.49 0.01 0.01 0.02 0.02 0.03 0.01 355.27 0.003 0.02 0.006 0.04 0.009 0.03 454.58 0.001 0.02 0.002 0.03 0.003 0.02 554.14 4.13e-4 0.02 6.67e-4 0.06 1.08e-3 0.04 653.84 1.76e-4 0.03 2.37e-4 0.07 4.14e-4 0.04 753.61 8.24e-5 0.04 8.48e-5 0.09 1.67e-4 0.05 853.44 3.91e-5 0.03 3.94e-5 0.14 7.85e-5 0.07 953.31 3.69e-5 0.40 1.17e-5 0.10 4.86e-5 0.31 1053.20 1.14e-5 0.05 5.59e-6 0.10 1.70e-5 0.05 Replace with Insert R-9

~

/

G '

,v -

/

/

" /

?---...

,,v

/

/

/

I"-.

/

.,v

/

/

Insert R-9 for replacement of Table A7A.7-3, Page 2 of 2, From the ISFSI Corners:

Distance from ISFSI Face (meters)

Distance from ISFSI Center (meters)

Gamma Radiation Dose Rate (mrem/hr)

Neutron Radiation Dose Rate (mrem/hr)

Total Skyshine Dose Rate (mrem/hr) 10 77.91 4.42E+00 7.33E+00 1.17E+01 45 107.91 6.03E-01 1.15E+00 1.75E+00 100 159.24 4.21E-02 1.72E-01 2.14E-01 200 256.49 1.40E-02 2.86E-02 4.27E-02 300 355.27 4.21E-03 1.03E-02 1.45E-02 400 454.58 1.40E-03 2.86E-03 4.27E-03 500 554.14 5.79E-04 9.55E-04 1.53E-03 600 653.84 2.47E-04 3.39E-04 5.86E-04 700 753.61 1.16E-04 1.21E-04 2.37E-04 800 853.44 5.48E-05 5.64E-05 1.11E-04 900 953.31 5.17E-05 1.68E-05 6.85E-05 1000 1053.20 1.60E-05 8.00E-06 2.40E-05