Text
.
UNITED STATES p,g jo NUCLEAR REGULATORY COMMisslON
[
REGION I o
631 PARK AVENUE C
KING OF PRUSSI A, PENNSYLVANIA 19406
%*****/
SEP 1 3 1979 Docket No.70-371 United Nuclear Corporation UNC Naval Products ATTN: Mr. D. E. Ganley President 67 Sandy Desert Road Uncasville, Connecticut 06382 Gentlemen:
Subject:
Inspection 70-371/79-09 This refers to the inspection conducted by Mr. I. Cohen of this office on May 17-24,1979, of activities authorized by NRC License No. SNM-368 and to the discussions of our findings held by Mr. Cohen with Mr. T. Collopy of your staff at the conclusion of the inspection.
Areas examined during this inspection are described in the Office of Inspection and Enforcement Inspection Report which is enclosed with this letter. Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations by the inspector.
Based on the results of this inspection, it appears that one of your activities was not conducted in full compliance with NRC requirements, as set forth in the Notice of Violation, enclosed herewith as Appendix A.
This item of noncompliance has been categorized into the levels as described in our correspondence to you dated December 31, 1974.
This notice is sent to you pursuant to the provisions of Section 2.201 of the NRC's " Rules of Practice,"
Part 2, Title 10, Code of Federal Regulations.
Section 2.201 requires you to submit to this office, within twenty (20) days of your receipt of this (1) corrective notice, a written statement or explanation in reply including (:2) corrective steps which have been taken by you and the results achieved; steps which will be taken to avoid further items of noncompliance; and (3) the date when full compliance will be achieved.
In accordance with Section 2.790(d) of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations, documentation of findings of your control and accounting procedures for safeguarding special nuclear materials and your facility security procedures are exempt from disclosure; therefore, the enclosures to this letter, and your response to this letter will not be placed in the Public Document Rocm and will receive limited distribution.
1632 243 7 9122 00 0 E l
l SEP 1 3 1979 United Nuclear Corporation 2
Should you have any questions concerning this inspection, we will be pleased to discuss them with you.
Sincerely, Walter G. Martin, Chief Safeguards Branch
Enclosures:
1.
Appendix A, Notice of Violation (Contains 2.790 Information) 2.
Office of Inspection and Enforcement Inspection Report Number 70-371/79-07) (Contains 2.790 Information) 1632 244 i
l i
I i
i