Commits to Addl Confirmatory Condensation Oscillation Tests in full-scale Test Facility,Outlined in GE Re Mark I Containment Program.Schedule for Submittal of Plant Unique Analysis Will Be Provided Following NRC Resolution
ML19210E687
Person / Time
Site: Hatch  
Issue date: 11/30/1979
From: Kelly R
GEORGIA POWER CO.
To:
Office of Nuclear Reactor Regulation
References
TAC-07939, TAC-07940, TAC-7939, TAC-7940, NUDOCS 7912050533
Download: ML19210E687 (2)


Text

a D

Georgia Power Cornpany 230 Peachtree Street dost Office Box 4545 At:anta. Georgia 30302 Telephone 404 522-6060 R.J.Kelty November 30, 1979 Geor9ia Power vce President and General Manager o

Power Generaton the southern estnc systern U. S. Nuclear Regulatory Commission Office of Nuclear P2 actor Regulation Washington, D. C.

20555 NRC DOCKETS 50-321 AND 50-366 OPERATING LICENSES DPR-57 AND NPF-5 EDWIN I. HATCH NUCLEAR PLANT UNITS 1 AND 2 MARK I CONTAINMENT PROGRAM Gentlemen:

Your letter of October 1,1979, (Reference 1) requested that each licensee commit, on behalf of the Mark I Owners Group as a whole, to perform additional confirmatory cuadensation oscillation tests in the Full-Scale Test Facility (FSTF). Georgia Power Company hereby commits to the additional testing as outlined in General Electric's letter dated November 30, 1979, (Reference 3).

Your letter of October 31, 197'9, (Reference 2) requested that Georgia Power company provide a schedule for submittal of the Long-Term Program Plant Unique Analysis for Plant Hatch. However, several of the NRC specifications in the Acceptance Criteria provided with the October 31, 1979, letter represent significant differences from the Mark I Containment Load Definition Report (LDR) and are inconsistent with the technical information provided by the Mark I program. The specific NRC criteria of concern are addressed in General Electric's letter dated November 30, 1979, (Reference 3).

Further consideration of these specific criteria by the NRC will be pursued through the Mark I Owners Group.

Because the Plant Unique Analysis depends in part on final resolution of all acceptance critiera, the schedule for submittal of the Plant Unique Analysis wi:1 be provided following final ~ resolution of the above concerns.

Yours very truly, R. J. Kelly JAB /mb 1502 279 Attachment xt: Ruble A. Thomas j

George F. Trowbridge, Esquire y

R. F. Rogers, III

  • */g b
  1. 0 7sicoso g

,w GeorgiaPower A U. S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation November 30, 1979 Page Two ATTACHMENT

REFERENCES:

(1) Letter dated October 2,1979, from D. G. Eisenhut (NRC) to all Mark I Utilities; subject

" Confirmatory Requirements Relating to Condensation Oscillation Loads for the Mark I Containment Long-Term Program" (2) Letter dated October 31, 1979, from D. G. Eisenhut (NRC) to all Mark I Utilities; subject

" Acceptance Criteria for the Mark I Containment Long-Term Program" (3) Letter dated October 30, 1979, from L. J. Sobon (GE) to D. G.

Eisenhut (NRC); subject

" Mark I Containm' nt Program, NPC Acceptance Criteria for the Mark I Long-T cm Program" 1502 280 JAB /mb 11/30/79

__