Forwards First Interim Deficiency Rept Re Damaged Tubes in Containment Spray Heat Exchanger
Date released: 08/12/2019 Download: ML19210E680


First Interim Deficiency Rept Re Damaged Tubes in Containment Spray Heat Exchanger.Caused by Improper Design of Tube Bundle Supports,Resulting in Flow Induced Vibration. Full Flow Vibration Test Scheduled
ML19210E684
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 11/23/1979
From:
TENNESSEE VALLEY AUTHORITY
To:
References
Download: ML19210E684 (1)
Forwards First Interim Deficiency Rept Re Damaged Tubes in Containment Spray Heat Exchanger
ML19210E679
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 11/23/1979
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19210E679 (1)