ML19210E679

From kanterella
Jump to navigation Jump to search
Forwards First Interim Deficiency Rept Re Damaged Tubes in Containment Spray Heat Exchanger
ML19210E679
Person / Time
Site: Sequoyah  
Issue date: 11/23/1979
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19210E680 List:
References
NCR-16P, NUDOCS 7912050524
Download: ML19210E679 (1)


Text

.

P TENNESSEE VALLEY AUTHORITY CH ATTANOOG A. TENN E*'"EE 37401 400 Chestnut Streec 'wer II November 23, 1979 Mr. James O'Railly, Director office of In ection and Enforcement U.S. Nuclear gulatory Commission Region II - Sui e 3100 101 Marietta Str e Atlanta, Georgia 0303

Dear Mr. O'Reilly:

' QuurAH NUCLEAR PLANT UNITS 1 AND 2 - DAMAGED TUBES IN C0hTAINMENT SPRAY HEAT EXCHANGER - NCR 16P - FIRST INTERIM REPORT The subject deficiency was initially reported to NRC-OIE Inspec.cor W. Cottle on October 25, 1979, in accordance with 10 CFR 50.5S(s).

Enclosed is our first interim report. We expect to submit our next report by February 1, 1980.

If you have any questions concerning this matter, please get in touch with D. L. Lambert at FTS 854-2581.

Very truly yours, TENNESSEE VALLEY AUTHORITY L. M. Mills, Manager Nuclear Regulation and Safety Enclosure j

cc:

Mr. Victor Stallo, Jr., Director (Enclosure)v Office of Inspection and Enforcement U.S. Naclear '.agulatory Commission Washington, TC 20555 1502 267 g e e,g g wy o

sem

. A X m

So/7 SG

~

!/1 7 912056 3 h t[

An Equal Opportunity Employe