Docket No. 50-341 The Detroit Edison Compar.y ATTN:

Mr. Edward Hines, Assistant Vice President and Manager 0:ality Assurance 2000 Second Avenue Detroit, MI 48226 Gentlemen:

The enclosed IE Informat. ion Notice No. 79-27 provides information with regard to the sequence of events that followed incidents involvir.g steam generator tube ruptures at two PkT< units.

Sincerely, u.6 James G. Keppler Director

Enclosures:

1.

IE Information Notice No. 79-27 2.

Recently Issued IE Information Notices cc w/encls:

Central Files Director, NRR/DPM Director, NR"/ DOR PDR Local PDR NSIC TIC Ronald Callen, Michigan Public Service Commission Eugene B. Thomas, Jr.,

Attorney 7

j 7 911280 N8

i SSINS No.:

6870 Accession No.:

7910250488 UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON D.C.

20555 November 16, 1979 IE Information Notice No. 79-27 STEAM GENERATOR TLIBE RUPTURES AT TWO PWR PLANTS Description of Circumstances:

In recent months two incidents involving steam generator tube ruptures have occurred.

In both instances, the units were cooled down and placed in the residual heat removal mode with existing procedures.

Event of June 25, 1979 at the Doel 2 Nuclear Power Plant in Belgium The first event occurred on June 25, 1979, at the Doel 2 nuclear power plant in Belgium.

The Doel unit is a 390 Mwe Westinghouse two-loop reactor.

The event consisted of a rupture of several tubes in the loop B steam generator.

The resultant leakage between the primary and secondary systems was estimated to be 125 gpm.

The event started when the plant was heated up after a shutdown caused by a malfunction of the main steam isolation valve.

At the time of the incident the primary coolant pressure was:

2233 psi and the temperature:

491 F.

The reactor remained subtritical throughout the event.

The first indication of abnormal behavior was a rapid decrease of the primary system pressure (approximately:

28 psi / min.).

This was followed by the sequence of events listed below:

Time, min.

1.

Increase of cnarging flow demand, requiring startup of a second 1.8 charging pump.

2.

Automatic isolation of the CVC 3.

Shut off of the pressurizer h DUPLICATE DOCUMENT l 4,) c 4 a7 J