Text
'
f nu
/
m#'
UNITED STATES 8 'y),,,
NUCLEAR REGULATORY COMMISSION REGION lit
- .%.e 1
'.f 799 ROUStVELI fiOAD
%% /
ni SN w i yN. ii.uNOIS 80W
- ,sas September 11, 1979 MEMORANDUM FOR:
D. th Boyd, Chief, Reactor Projects Section 3 gi'bA.E. Davis, Chief, Fuc1 Facility and Materials THRU:
Safety Branch FROM:
T. H. Essig. Chief, Environmental and Special Projects Section
SUBJECT:
LICENSE RENEWALS FOR IDENTTFIEL RESEARCH REACTORS (A/I H07001937)
IIniversity of Mirsouri at Rolla The license (50-123 Docket, R-79 Licence) doco not require the licensec to have or adhere to, un emergency plan.
The licensee has no formal emergency plan.
The liccusee's emergency preparedness is based on the Hazards Sutumery Report, which discusses the scope of potential hazards and provides some criteria and information for use in incident response.
The licenuce's Standard Operating l'rocedures (SOP) also contain general information pertaining to emergencies.
it is reco= mended that the new license be written to require the licensee to cmiutain, and auhcre to, a formal cmcrgency plan. The plan chould conform to ANST 15.16 and Reg. Cuide 2.6 an appropriate for thtr. f acility.
IIniverwity of Illinois The 11cenace's technical cpecification 6.3.d requires the licensee to have, and adhere to, written emergency procedures. The emergency plan is the sane for tae LOPRA (50-356/R-117) reactor and tl.e TRIGA (50-151/R-115) reactor.
The plan resembic.s Reg. Cuide 2.6, but docc not follow it exactly.
It is reco= mended that the plan be required to conform to ANSI 15.16 and Rct,. Cuido 2.0 ao appropriate for this facility.
7011270 /
- _ 1/!02 Oil
D. C. Boyd September 11, 1979 University of lows The liceuwe (50-116/R-59) docs not require the licensee to have, or Adhara Lo, an eraergonny plan. However, the licensee has a formal 2:nergency Plan VILh Impicmenting Procedurec.
?:he plan 19 a good, comprehensiva plan, which is based on ANS1 15.16.
It is probably the most comprehensive and best thought-out plan for research eactors in the enti en region.
The plau la reviewed, and updated if necessary, anntmtly by the Rad 1ation Saf ety Cor::mittee.
The licensee conducts training in the Fmergency Plan at least annually, and also conducts an Annual drill, in conjunction with the Student llealth Services Lad Radiation Services Group, which provide.n radiation prutectivu services to the licencee.
iL is recommended that the new itcenAe ha written to require the licensee to maintain, and udhere to, their emergency plan.
\\lf.i 1
T. H. Essig, Chief Environmental and Special ProjectM SecLion I
t n
iv.
~v
)
.