ML19210D196
| ML19210D196 | |
| Person / Time | |
|---|---|
| Site: | Cooper |
| Issue date: | 10/12/1979 |
| From: | Madsen G NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| To: | Pilant J NEBRASKA PUBLIC POWER DISTRICT |
| Shared Package | |
| ML19210D197 | List: |
| References | |
| NUDOCS 7911260028 | |
| Download: ML19210D196 (2) | |
See also: IR 05000298/1979014
Text
7 /C
p"%[o,
UNITED STATES
g*
y yg
( ,g
NUCLEAR REGULATORY COMMISSION
E $A'
fpj
REGION IV
0,
A
-
611 RYAN PLAZA DRIVE, SUITE 1000
D
ARLINGTON, TEXAS 76012
,o
'**
October 12, 1979
In Reply Refer To:
Docket No. 50-298/79-14
Nebraska Public Power District
ATTN: Mr. J. M. Pilant, Director
Licensing and Quality Assurance
P. O. Box 499
Columbus, Nebraska 68601
Gentlemen:
This refers to the inspection conducted by Messrs. G. L. Constable, R. Smith
and S. R. Dean of this office during the period September 10-14 and 19-21,
1979, of activities authorized by NRC Operating License DPR-46, and to the
discussions of the findings with Mr. L. C. Lessor.
Principal areas examined during the inspection included:
(1) review of plant
operations; (2) Quality Assurance Program; (3) Part 21 Report; (4) follow-up
on IE Bulletins; (5) IE Circulars; and (6) LER's. Within these areas, the
inspection consisted of selective examination of procedures and representative
records, interviews with personnel, and observations by the inspectors.
Based on the results of this inspection it appears that certain of your
activities were not conducted in full compliance with NRC requirements, as
set forth in the Notice of Violation, enclosed herewith as Enclosure (1).
This notice is sent to you pursuant to the provisions of Section 2.201 of the
NRC's " Rules of Practice," Part 2, Code of Federal Regulations. Section 2.201
requires you to submit to this office within 20 days of your rn:eipt of this
notice, a written statement or explanation in reply including:
(1) corrective
steps which have been taken by you, and the results achieved; (2) corrective
steps which will be taken to avoid further noncompliance; and (3) the date when
full compliance will be achieved.
In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2, Title
10, Code of Federal Regulations, a copy of this letter arid the enclosed inspec-
tion report will be placed in the NRC's Public Document Room.
If this report
1392
329
d2f
g 7011280
.
.
Nebraska Public Power District
-2-
October 12, 1979
contains any infonnation that you or your contractors believe to be propri-
etary, it is necessary that you make a written application within 20 days
to this office to withhold such information from public disclosure. Any
such application must include a full statement of reasons on the basis of
which it is claimed that the information is proprietary and should be prepared
so that the proprietary information identified in the application is contained
in a separate part of the document.
If we do not hear from you in this regard
within the specified period, the report will be placed in the Public Document
,
Room.
Should you have any questions concernin9 this inspection, we will be pleased
to discuss them with you.
Sincerely,
$"kJ0
G. L. Madsen, Chief,
Reactor Operations and
Nuclear Support Branch
Enclosures:
1.
2.
IE Inspection Report No. 50-298/79-14
cc w/ enclosures:
L. C. Lessor, Superintendent
Cooper Nuclear Station
P. O. Box 98
Brownville, Nebraska 68321
)f
b
d f
?.
- - . . . - - -
. .- .. _
- - - -
-
. . - - - - - ~
__