.c y ^1,0 C

  • )

~

/

UN!'.7 STATES

~

f ; ), 7g NUCLEAR REGULATORY COMMISSION

,. g c g #y WASHINGTON. D. C. 20555

%, '..M.. f oece.-ter 9, ion T) ALL PWR FACILITY LICENSEES Gentlemen:

The NRC staff has recently been engaged in a series of discussions with reactor vendors, EPRI, and the Steam Generator Owners Groups concerning steam generator operational problems. Central to these discussions is an accurate assessment of operational conditions and experiences as well as the programs aimed towards the resolution of these problems.

In order to ensure that both the NRC and the nuclear industry have available a comprehensive collection of operating data for steam gener-ators to permit info.ned, timely decisions and actions, D0R is establishing a steam generator information system. The system will collect appropriate informatf or. from all PWR licensees which will periodically be published.

It is presently anticipated that the initial publication of information will be in the early part of 1978. You will be sent a copy of this and all future publications.

This information system will enable the NRC and each Licensee to draw from the operational experiences of the entire nuclear industry when making any aecisions concerning steam generators. This should result in both safety and economic benefits.

Enclosed is a questionnaire which we request that you complete for each of your operating PWR units. We believe that the questionnaire is self explanatory, however, if questions arise or any clarifica-tions are necessary, please do not hesitate to contact your NRC Projectilanager. Please include with your response -ny diagrams you may have available which illustrate the tube plugging and/or the tube degradation patterns.

To enable us to maintain the information current, you are further requested to subnit in the same format indicated by the question-naire, any changes or additions to your initial submittal to reflect the future operating experience with your steam generators, i.e., the results of future steam generator inspections. The questionnaire should be completed to the extent applicable and appropriate at this time,

.e. regardless of operating experience.

1492 303 f4 b77 p

'2910300 The information being requested is quite extensive and will require a diligent effort on your part and ours to assure accurate and timely completion. Also, we realize that parts of the information may already be available to the NRC, but not in a convenient format which is readily accessible. Therefore, we request that you assist us by returning a single completed copy of the enclosed questionnaire to the Director of Nuclear Reactor Regulation, U. S. Nuclear Regulatory Commission, Washington, D. C.

20555, within 60 days of receipt of this letter. Please include any comments er suggestions for improving this information system which you may have.

This request for generic information was approved by GA0 under a bleket clearance number R0071; this clearance expires September 30, 1978.

Sincerely, Karl R. Goller, Assistant Director for Operating Reactors Division of Operating Reactors

Enclosure:

Steam Generator Operating History Questionnaire cc w/ enclosure:

See next page 4

1492 305 e

Docket No. 50-313 Arkansas Power & Light Company ATTN: Mr. William Cavanaugh, III Executive Director Generation and Construction Department P. O. Box 551 Little Rock, Arkansas 72203 cc: Phillip K. Lyon, Esquire House, Holms & Jewell 1550 Tower Building Little Rock, Arkansas 72201 Mr. Daniel H. Williams Manager, Licensing Arkansas Power & Light Company Post Office Box 551 Little Rock, Arkansas 72203 Mr. John W. Anderson, Jr.

Plaat Superintendent Arkansas Nuclear One Post Office Box 608 Russellville, Arkansas 72801 Arkansas Polytechnic College Russellville, Arkansas 72801

7 T

5 1492 305-

Docket Nos. 50-317 and 50-318 Baltimore Gas and Electric Company ATTN: Mr. A. E. Lundvall, Jr.

Vice President - Supply P. O. Box 1475 Baltimore, Maryland 21203

' cc: James' A. Biddison, Jr.

General Counsel G and E Building Charles Center Baltimore, Maryland 21203 George F. Trowbridge, Esquire Shaw, Pittman, Potts and Trowbridge 1800 M Street, N. W.

Washington, D. C.

20036 Mr. R. C. L. Olson Baltimore Gas and Electric Company Room 922 - G and E Building Post Office Box 1475 Baltimore, Maryland 21203 Mr. R. M. Douglass, Chief Engineer Calvert Cliffs Nutlear Power Plant Baltimore Gas and Electric Company Lusby, Maryland 20657 Bechtel Power Corporation ATTN: Mr. R. L. Ashl ey Chief Nuclear Engineer P. O. Box 607 Gaithersburg, Maryland 20760 Combustion Engineering, Inc.

ATTN: Mr. J. A. Honey Project Manager P. O. Box 500 Windsor, Connecticut 06095 Calvert County Library Prince Frederick, Maryland 20678

}kh2.

4

Ddcket No. 50-261 Carolina Power & Light Company ATTN:

Mr. J. A. Jones Senior Vice President 336 Fayetteville Street Raleigh, North Carolina 27602 cc: Hartsville Memorial Library Home and Fifth Avenue Hartsville. South Carolina 29550 Docket No. 50-213 Connecticut Ya;ikee Atomic Power Company ATTN:

Mr. Donald C. Switzer President Post Office Box 2/C Hartford, Connecticut 06101 cc: Day, Berry, & Howard Counselors at Law One Constitution Plaza Hartford, Connecticut 06103 Russell Library 119 Broad Street Middletown, Connecticut 16457 1492 307

Docket Nos. 50-3 and 50-241 Consolidated Edison Company of New York, Inc.

ATTN: Mr. William J. Cahill, Jr.

Vice President 4 Irving Place New York, New York 10003 cc: Leonard M. Trosten, Esquire LeBoeuf, Lamb, Leiby & MacRae 1757 N Street, N. W.

Washington, D. C.

20036' Paul S. Shemin, Esquire Assistant Attorney General State of New York Department of Law Two World Trade Center New York, New York 10047 Sarah Chasis, Esquire Natural Resourccs Defense Council 122 East 42nd Street New York, New York 10017 Director, Technical Development Programs State of New York Energy Office Agency Building 2 Empire State Plaza Albany, New York 12223 Anthony Z. Roisman, Esquire Sheldon, Harmon & Roisman 1025 15th Street, N. W., 5th Floor Washington, D. C.

20005 White Plains Public Library 100 Martine Avenue White Plans, New York 10601 g g 30B

~,.

i

e Docket No. 50-255 Consumers Pow 2r Company ATTN: Mr. Dave Bixel Nuclear L; censing f.dminstrater 212 West Michigan. avenue Jackson, Michigan 49201 cc:

M. I. Miller, Esquire 1 sham, Lincoln & Beale Suite 4200 One First National Plaza Chicago, Illinois 60670 J. L. Bacon, Esquire Consumers Power Company 212 West Michigan Avenue Jackson, Michigan 49201 Paul A. Perry, Secretary Consumers Power Company 212 West Michigan Avenue Jackson, Michigan 49201 Kalamazoo Public Library 315 South Rose Street Kalamazoo, Michigan 49006 Myron M. Cherry, Esquire Suite 4501 One IBM Plaza Chicago, Illinois 60611 1492 30Cl

Docket No. 50-286 Consolidated Edison Company of New York, Inc.

ATTN: fir. William J. Cahill, Jr.

Vice President 4 Irving Place New York, New York 10003 cc: Admiral Paul Early (IP-3)

Power Authority of the State of New York 10 Columbus Circle New York, New York 10019 White Plains Public Library 100 Martine Avenue White Plains, New York 10601 Docket Nos. 50-295 and 50-304 Commonwealth Edison Company ATTN: Mr. R. L. Bolger Assistant Vice President Post Office Box 767 Chicago, Illinois 60690 cc: Mr. John W. Rowe Isham, Lincoln & Beale Counselors at Law One First National Plaza, 42nd Floor Chicago, Illinois 60603 Robert J. Vollen, Esquire 109 North Dearborn Street Chicago, Illinois 606r2 Dr. Cecil Lue-Hing Director of Research & Develooment Metropolitan Sanitary District of Greater Chicago 100 East Erie Street Chicago, Illinois 60611 Waukegan Public Library 128 North County Stree; 14 g

.$10 Waukegan, Illinois 60085 i; :, '

m

Docket No. 50-334 Duquesne Light Company ATTN:

Mr. C. N. Dunn, Vice President Operations Division 435 Sixth Avenue Pittsburge, Pennsylvania 15219 cc:

Karin Carter, Esq.

Special Assistant Attorney General Bureau of Administrative Enforcement 5th Floor, Executive House Harrisburg, Pennsylvania 17120 Marvin Fein Utility Counsel City of Pittsburgh 313 City-County Building Pittsburgh, Pennsylvania 15219 Mr. J. M. Cumiskey Stone & Webster Engineering Corporation P. O. Box 2325 Boston, Massachusetts 02107 Mr. J. D. Woodward R&D Center Westinghouse Electric Corporation Building 7-303 Pittsburgh, Pennsylvania 15230 Mr. Jack Carey Technical Assistant Duquesne Light Company P. O. Box 4 Shippingport, Pennsylvania 15077 Mr. R. E. Martin Duquesne Light. Company 435 6th Avenue Pittsburgh, Pennsylvania 15219 Beaver Area Memorial Library 100 College Avenue Beaver, Pennsylvania 15009 1492 3II

\\

Docket Nos. 50-269 50-270 and 50-297 Duke Power Company ATTN:

Mr. William 0. Parker, Jr.

Vice President Steam Production Post Office Box 2178 422 South Church Street Charlotte, North Carolina 28242 cc: fir. William L. Porter Duke Power Company Post Of fice Box 2178 422 South Church Street Charlotte, North Carolina 28242 J. Michael McGarry, III, Esquire DeBevoise & Liberman 700 Shoreham Building 806 - 15th Street, 11. W.

Washington, D. C.

20005 Oconee County Library 201 South Spring Street Walhalla, South Carolina 29691 r

1492 312

Docket No. 50-315 Indiana & Michigan Electric Company Indiana & Michigan Power Company ATTN:

Mr. John Tillinghast Vice President P. O. Box 18 Bowling Green Station New York, New York 10004 cc: Mr. Robert Hunter Vice President American Electric Power Service Corporation 2 Broadway New York, New York 10004 Gerald Charnoff, Esquire Shaw, Pittman, Potts & Trowbridge 1800 M Street, N. W.

Washington, D. C.

20036 Donald Cook Nuclear Plant ATTN: Mr. D. Shaller Plant Manager P. O. Box 458 Bridgman, Michigan 49106 Mr. David Dinsnore Comey Executive Director Citizens for a Better Environment 59 East Van Buren Street Chicago, Illinois 60605 Maude Reston Palenske Memorial Library' 500 Market Street St. Joseph, Michigan 49085 1492 313

Docket Nos. 50-250 and 50-251 Florida Power & Light Company ATTN:

Dr. Robert E. Uhrig Vice President P. O. Box 013100 Miami, Florida 33101 cc: Mr. Jack R. Plewman, Esquire Lowenstein, Newman, Reis & Axelrad 1025 Connecticut Avenue, N.

Suite 1214 Washington, D. C.

20036 Environmental & Urban Aff airs Library Florida International University Miami, Florida 33199 Docket No. 50-335 Florida Power & Light Company ATTN:

Dr. Robert E. Uhrig Vice President Nuclear and General Engineering Post Office Box 013100 111ami, Florida 33101 cc: Robert Lowenstein, Esquire Lowenstein, flewman, Reis & Axelrad 1025 Connecticut Avenue, H. W.

Washington, D. C.

20036 Norman A Coll, Esquire McCarthy, Steel, Hector & Davis 14th Floor, Cirst National Bank Building Miami, Florida 33131 Indian River Junior College Library 3209 Virginia Avenue Ft. Pierce, Florida 33450 Docket No. 50-302 Mr. W. P. Stewart Director, Power Production Florida Power Corporation P. 0. Box 14042, Mail Stop C-4 St. Petesburg, Florida 33733 cc: Mr. S. A. Brandimore Vice President and General Counsel

}(N blk P. O. Box 14042

~ St. Petersburg, Florida 33733 Crystal River Public Library Crystal River, Florida 32629

y Docket Nos. 50-282 and 50-306 Northern States Power Company ATTN: Mr. L. O. Mayer, !!anager Nuclear Support Services 414 flicollet itall - 8th Floor Minneapolis, ttinnesota 55401 cc: Gerald Charnoff, Esquire Shaw, Pittman, Potts and Trwobridge 1800 M Street, N. W.

Washington, D. C.

20036 fir. F. P. Tierney Plant Manager Prairie Island Nuclear Generating Plant Northern Statcs Power Company Route 2 Welch, Minnesota 55089 Sandra S. Gardebring Executive Director Minnesota Pollution Control Agency 1935 W. County Road B2 Roseville, Minnesota 55113 Jocelyn F. Olson, Esquire Special Assistant Attorney General Minnesota Pollution Control Agency 1935 West County Road B-2 Roseville, Minnesota 55113 rr, Robert L. Nybo, Jr., Chai rman Minnesota-Wisconsin Boundary Area Commission 619 Second Street Hudson, Wisconsin 54016 The Environmental Conservation Library Minneapolis Public Library 300 Nicollet !!all itinneapolis, Minnesota 55401 1492 315

Docket' No. 50-289 Metropolitan Edi son Coinpany ATTN:

Mr. J. G. Herbein Vice President P. O. Box 542 Reading, Pennsylvania 19603 cc: GPU Service Corporation Richard W. Heward, Project Manager Mr. i. Gary Broughton, Safety and Licensing Manager 260 Cherry Hill Road Parsippany, New Jersey 07054 Pennsylvania Electric Company Mr. R. W. Conrad Vice President, Generation 1001 Broad Street Johnstown, Pennsylvania ir;07 Miss Mary V. Southard, Chairman Citizens for a Safe Environment P. O. Box 405 Harrisburg, Pennsylvania 17108 Government Publications Section State Library of Pennsylvania Box 1601 (Education Building)

Harrisburg, Pennsylvania 17126 Docket No. 50-336 Northeast Nuclear Energy Company ATTN:

Mr. D. C. Swi tzer President P. O. Box 270 Hartford, Connecticut 06101 cc: William H. Cuddy, Esquire Day, Berry & Howard Counselors at Law One Constitution Plaza Hartford, Connecticut 06103 Northeast Nuclear Energy Company ATTN:

Superintendent Millstone Plant P. O. Box 128 Waterford, Connecticut 06385 l4h2 3lb Waterford Public Library Rope Ferry Road, Toute ig6

, Waterrera, Connecticut uoaoa VV.

Docket No. 50-272 Public Service Electric & Gas Company ATTN: Mr. R. P. Librizzi General Manager - Electric Production Production Department 80 Park Place, Room 7221 Newark, New Jersey 07101 cc: Richard Fryling, Jr., Esquire Assistant General Counsel Public Service Electric & Gas Company 80 Park Place Newark, New Jersey 07101 Troy B. Conner, Jr., Esquire 1747 Pennsylvania Avenue, N. W.

Washington, D. C.

20006 Gene Fisher Bureau Chief Bureau of Radiation Protection 330 Scotts Road Trenton, New Jersey 08628 State House Annex ATTN: Deputy Attorney General State of New Jersey 36 West State Street Trenton, New Jersey 08625 Attorney General Department of Law & Public Safety State House Annex Trenton, New Jersey 08625 Public Service Electric & Gas Company ATTN: Herbert J. Heller Manager, Salem Nuclear Generating Station Hancocks Bridge., New Jersey 08038 Salem Free Libr5ry 112 West Broadway Salem, New Jersey 08079 Public Service Electric & Gas Company ATTU:

R. L. Mi tti General Manager - Licensing and Environnent 80 Park Place 1A07

't 1 7 Newark, New Jersey 07101 I4/C Ii s

Docket No. 50-285 Omaha Public Power District ATTd: Mr. Theodore E. Short Division Manager - Production Operations 1623 Harney Street Omaha, Nebraska 68102 cc: Margaret R. A. Pardis LeBoeuf, Lamb, Leiby & MacRae 1757 N Street, N. W.

Washington, D. C.

20036 Blair Public Library 1665 Lincoln Street Blair, Nebraska 68008 Docket No. 50-344 Portland General Electric Company ATTN: Mr. Charles Goodwin, Jr.

Assistant Vice President 621 SW Alder Street Portland, Oregon 97205 j

cc: fir. H. H. Phillips Portland General Electric Company 621 Southwest Alder Street Electric Building Portland, Oregon 97205 Warren Hastings, Esquire Phillips, Coughlin, Buell Stoloff and Black 807 Electric Building Portland, Oregon 97205 Mr. J. L. Frewing, Manager Generation Licensing and Analysis Portland General Electric Company 621 Southwest Alder Street Portland, Oregon 97205 Columbia County Courthouse Law Library, Circuit Court Room St. Helens, Oregon 97051

'?

1492 318

Docket No. 50-312 Sacramento Municipal Utility District ATTN: Mr. J. J. Mattimoe Assistant General Manager and Chief Engineer 6201 S Street P. O. Box 15830 Sacramento, California 95813 cc:

David S. Kaplan, Secretary and General Counsel 6201 S Street P. O. Box 15830 Sacramento, California 95813 Business and Municipal Department Sacramento City-County Library 828 I Street Sacramento, California 95814 Docket No. 50-206 Southern California Edison Company ATTN:

Mr. James H. Drake Vice President 2244 Walnut Grove Avenue Post Office Box 800 Rosemead, California 91770 cc: Rollin E. Woodbury, Vice President and General Counsel Southern California Edison Company Post Office Box 800 Rosemead, California 91770 Chickering & Gregory, General Counsel ATTN:

C. Hayden Ames, Esquire San Diego Gas & Electric Company 111 Sutter Street San Francisco, California 94104 Mission Viejo" Branch Library 24851 Chrisanta Drive Mission Viejo, California 92676 1492 319

M Docket No. 50-244 Rochester Gas & Electric Corporation ATTN: Mr. Leon D. White, Jr.

Vice President Electric and Steam Production 89 East Avenue Rochester, New York 14604

.cc: Lex K. Larson, Esquire LeBoeuf, Lamb, Leiby & MacRae 1757 N Street, N. W.

Washington, D. C.

20036 Mr. Michael Slade 1250 Crown Point Drive Webster, New York 14580 Rochester Committee for Scientific Information Robert E. Lee, Ph.D Post Office Box 5236 River Campus Station Rochester, New York 14627 Jeffrey Cohen New York State Energy Office Swan Street Building Core 1, Second Floor Empire State Plaza Albany, New York-12223 Director, Technical Development Programs State of New York Energy Office Agency Building 2 Empire State Plaza Albany, New York 12223 Rochester Public Library 115 South Avenue.

Rochester, New York 14627 S

1~492 320

Docket No. 50-29 Yankee Atomic Electric Company ATTN: Mr. Robert H. Groce Licensing Engineer 20 Turnpike Road Westboro, Massachusetts 01581 cc: Mr. Donald G. Allen, President Yankee Atomic Electric Company 20 Turnpike Road Westboro, Massachusetts 01581 Greenfield Public Library 40 Main Street Greenfield, Massachusetts 01581 n

t 1492 321

G' Docket Nos. 50-180 and 50-?.11 Virginia Electric & Power Company ATTN:

Mr. W. L. Prof fitt Senior Vice President - Power P. O. Box 26666 Richmond, Virginia 23261 cc: Michael W. Maupin, Esq.

Hunton, Williams, Gay & Gibson P. O. Box 1535 Richmond, Virginia 23213 Swen Library College of William & Mary Williamsburg, Virginia 23185 Docket Nos. 50-266 and 50-301 Wisconsin Electric Power Company Wisconsin Michigan Power Company ATTN: 11r. Sol Burstein Executive Vice President 231 West Michigan Street Milwaukee, Wisconsin 53201 cc:

Mr. Arthur M. Fish Document Department University of Wisconsin -

Stevens Point Library Stevens Point, Wisconsin 54481 Docket No. 50-305 Wisconsin Public Service corporation ATTN:

Mr. E. W. James Senior Vice President Post Office Box 1200 Green Bay, Wisconsin 54305 cc:

Steven E. Keane~, Esquire Foley, Sammond & Lardner 777 East 'lisconsin Avenue

!!ilwaukee, Wisconsin 53202 Bruce W. Churchill, Esquire Shaw, Pittman, Potts & Trowbridge

'Q 1800 M Street, N. W.

gA Washington, D. C.

20036 14 Kewaunee'Public libra y 314 Milwaukee Street Kewaunee, Wisconsin 54216

Docket No. 50-309 Yankee Atomic Electric Company ATTN:

Mr. Robert H. Groce Licensing Engineer 20 Turnpike Road Westboro, Massachusetts 01581 cc: Mr. E. W. Thurlow, President Maine Yankee Atomic Power Company-9 Green Street Augusta, Maine 04330 Mr. Donald E. Vandenburgh Vice President - Engineering Yankee Atomic Electric Company 20 Turnpike Road Westboro, Massachusetts 01581 John A. Ritsher, Esquire Ropes & Gray 225 Franklin Street Boston, Massachusetts 02110 O

Mr. John M. R. Paterson Assistant Attorney General State of Maine Augusta, Maine 04330 Harold P. Green, Esquire Suite 1000 The Watergate 600 New Hampshire Avenue, N. W.

liashington, D. C.

20037 Mr. Nicholas Barth Executive Director Sheepscot Valley Conservation Association, Inc.

P. O. Box 125 Alna, Maine 04535 Wiscasset Public Library Association High Street Wiscasset, Maine 04578 Mr. Robert R. Radcliffe Office of Energy Resources 55 Capitol Street Augusta, Maine 04330 Mrs. Cali Hollander, President 1492 623 SAFE POWER FOR mal"E Stockton Springs, Maine 04981 t

IV. STEAM GENERATOR BLOWDOWN INFORMATION Frequency of Blowdown:

Normal Blowdown Rate:

Blowdown Rate w/ Condenser Leakage:

Chemical Analysis Results Results Parameter Control Limits V.

WATER CHEMISTRY INFORMATION Secondary Water Type of Treatment and Effective Full Power (EFP) Months of Operation:

Typical Chemistry or Impurity Limits:

Feedwater Typical Chemistry or Impurity Limits:

Condenser Cooling Water Typical Chemistry or Impurity Limits:

Demineralizers - Type:

Cooling Tower (open cycle, closed cycle or none):

1492 324

ENCLOSURE 1 STEAM GENERATOR OPERATING HISTORY QUESTIONNAIRE NOTE: All percentages should be reported to four significant figures.

I.

BASIC PLANT INFORMATION Plant:

Startup Date:

Utility:

Plant Location:

Thermal Power Level:

Nuclear Steam Supply System (NSSS) Supplier:

Number of Loops:

Steam Generator Supplier, Model No. and Type:

Number of Tubes Per Generator:

Tube Size and Material:

II. STEAM GENERATOR OPERATING CONDITIONS Normal Operation Temperature:

Flow Rate:

Allowable Leakage Rate:

Primary Pressure:

Secondary Pressure:

Accidents Design Base LOCA Max. Delta-P:

Main Steam Line Break (MSLB) Max. Delta-P:

III. STEAM GENERATOR SUPPORT PLATE INFORMATION Material:

Design Type:

Design Code:

Dimensions:

Flow Rate:

Tube Hole Dimensions:

Flow Hole Dimen,sions:

1492 425 Fretting or Vibration in U-Bend Area (not applicable to B&W S.G.) AS OF (4)

Percentage of Tubes Plugged Other Preventive Measures Wastage / Cavitation Erosion AS OF [41 Hot Leg:

(Repeat this information for the cold leg on Combustion Engineering (C.E.) and Westinghouse (W) 5.G.)

'~

Area of Tube Bundle (1) a b

c d

e

% of Tubes Affected by Wastage / Cavitation Erosion

% of Tubes Plugged Due to Exceedance of Allowable Limit (2)

% of Tubes Plugged That Did not Exceed Degradation Limit Location Above Tube Sheet (3)

Max. Wastage / Cavitation Erosion Rate for Any Single Tube (Tube Circum. Ave) (Mills / Month)

' Max. Wastage / Cavitation Erosion in Any Single Unplugged Tube (Tube Circum. Ave) (Mills)

CrackingASOF,(4l Caustic Stress Corrosion Induced in C.E. and W S.G.

Flow Induced Vibration Caused in B&W S.G.

1492 326

'VI.

TURBINE'STOP VALVE TESTING (applicable to Babcock & Wilcox (B&W) 5.G. only)

Frequency of Testing Actual:

Manufacturer Recomendation:

Power Level At Which Testing Is Conducted Actual:

Manufacturer Recommendation:

Testing Procedures (Stroke length, stroke rate, etc.)

Actual:

Manufacturer Recommendation:

VII. STEAM GENERATOR TUBE DEGRADATION HISTORY (The following is to be repeated for each scheduled ISI)

Inservice Inspection (ISI) Date:

Number of EFP Days of Operation Since Last Inspection:

(The following is to be repeated for each steam generator)

Steam Generator Number:

Percentage of Tubes Inspected At This ISI:

Percentage of Tubes Inspected At This ISI That Had Been Inspected At The Previous Scheduled ISI:

Percentage of Tubes Plugged Prior to This ISI:

Percentage of Tubes Plugged At This ISI:

Percentage of Tubes Plugged That Did Not Exceed Deg3dation Limits:

Percentage of Tubes Plugged As A Result of Exceedance of Degradation Limits:

Sludge Layer Material Chemical Analysis Results:

Sludge Lancing (date):

Ave. Height of Sludge Before Lancing:

Ave. Height of Sludge After Lancing:

Replacement, Retubing or Other Remedial Action Considered: (Briefly Specify Details)

Support Plate Hourglassing:

Support Plate Islanding:

Tube Metalurgical Exam Results:

7 s r Denting (Con't)

Support Max. Denting in Any Single

% of Tubes Affected By Plate Tube in Bundle Area Denting in Bundle Levels (Tube Ave) (Mills) (1)

Arca a

b c

d e

a b

c d

e 1

2 3

4 5

6 7

8 9

10 11 12 1492 328

.. Cracking (Con't)

Ret teg:

(nepeat this information for the cold leg on C.E. and E S.G.)

Area of Tube Bundle (I) a b

c' d

e

% of Tubes Affected By Cracking

% of Tubes Plugged Due to Cracking

% of Tubes Plugged That Did Not Exceed Degradation Limit Location Above (3)

Tube Sheet Rate of Leakage From Leaking Cracks (gpm)

Denting (Not applicable to B&W S.G.) AS OF (4)

Hot Leg:

(Repeat this infomation for the cold leg on C.E. and E S.G.)

Area of Tube Bundle (1) aj b

c d

e

% of Tubes Affected by Denting

% of Tubes Plugged Due to Exceedance of Allowable Limit (2)

% of Tubes Plugged That Did Not Exceed Degradation Limit Rate of Leakage Frcen Leaking Dents (gpm)

Max. Denting Rate for Any Single Tube (Tube Circum. Ave) (Mills / Month)

Max. Denting in Any Single Unplugged Tube (Tube Circum. Av:) (Mills)' -

?_ '< 2 9

-.E

.8-VIII. SIGNIFICANT STEAM GENERATOR ABNORMAL OPERATIONAL EVENTS DATE

SUMMARY

(Include event description; unscheduled ISI results, if performed; and subsequent remedial actions)

IX. CONDENSER INFORMATION Condenser Tube Leakage Detectable Detection Material Date Rate (gpm)

Limit Method X.

RADIATION EXPOSilRE HISTORY WITH RESPECT TO STEAM GENERATORS Date Exam Dosage (Man-Rem)

Repair Dosage (Man-Rem)

Comments 1492 '.s!i0

7_

TABLE KEY NOTE:

All percentages refer to the percent of the tubes within a given area of the tube bundle.

(1)

Area of the Tube Bundle No. of Tubes Within the Area a.

Periphery of Bundle (wi/20 rows for B&W; wi/10 rows for C.E. and W) b.

Patch Plate (wi/4 rows) c.

Missing Tube Lane (B&W only)

(wi/5 rows) c.

Flow Slot Areas (C.E. and W only) wi/10 rows) d.

Wedge Regions (C.E. and W only)

(wi/8 rows) e.

Interior of Bundle (remainder of tubes)

(2)

Allowable Limit for Wastage / Cavitation Erosion:

Allowable Limit For Denting:

(3) 1.

Specifies area between the tube sheet and the first support plate 2.

Specifies in the following locations: (list the additional locations)

Wastage / Cavitation Erosion:

Cracking:

(4)

Specify the. d te of the inspection for which results have been tabulated.

i' r 1492 331

s

_g.

XI. DEGRADATION HISTORY FOR EACH TYPE OF DEGRADATION EXPERIENCED FOR TEN REPRESENTATIVE, UNPLUGGED TUBES FOR WHICH THE RESULTS OF TWO OR MORE ISI'S ARE AVAILABLE If the results for ten tubes are not available, specify this info <-

mation for all those tubes for wnicn results are available.

(repeat the following information for each tube and degradation type)

Steam Generator No:

Tube Identification:

Type of Degradation:

(specify denting, wastage, cavitation erosion, caustic stress corrosion cracking, or flow induced vibration cracking)

(repeat the following information chronologically for each ISI for which results are available)

ISI Date:

Amount of Degradation:

(specify amount and units)

EFP Months of Operation Since Last ISI for Which Results are Given:

1492 332

.