'l TENNESSEE VALLEY AUTHORITY

. ch.ET5NobdA. TENNESSEE 374o1

~

.3

.., 400 Chestnut Street Tower II 79 fC T 3L P 2; 0 2 October 1, 1979 s

Mr. James P. O'Reilly, Director Office of Inspection and Enforcement U.S. Nuclear Regulatory. Comission Region II - Suite 3100 101 Marietta Street Atlanta, Georgia 30303

Dear Mr. O'Reilly:

HARTSVILLE AND PHIPPS BEND NUCLE.'.R PLANTS ALL UNITS - REPORTABLE DEFICIENCY - UNACCEPTABLE BENDING OF WELDED STUD ANCHORS ON EMBEDDED PLATES- (NCR'S HNP-A-064 AND PBNP-039)

Initial report of the subject deficiency was made to W. B. Swan, NRC-0IE, Region II, on August 30, 1979, for the Hartsville Nuclear Plant and on August 31, 1979, for the Phipps Bend Nuclear Plant. In compliance with paragraph 50.55(e) of 10 CFR Part 50, we are enclosing the first interim report of the subject deficiency. We anticipate transmitting another report to NRC-0IE on or before June 1, 1980. If you have any questions regarding this matter, please call Tish Jenkins at FTS 854-2014.

Very truly yours, TENNESSEE VALLEY AUTHORITY

. M. Mills, ager Nuclear Regulation and Safety Enclosure cc: Mr. Victor Stello, Director (Enclosure)

Office of Inspection and Enforcement U.S. Nuclear Regulatory Comission Washington, DC 20555 A

b t 1174 274 7 'I O190 pg, Umcut copy An Equal Opportunity Employer