Responds to NRC Re Violations Noted in IE Insp Repts 50-317/79-07 & 50-318/79-06.Corrective Actions:New Monthly Surveillance Test Procedures Issued to Check Locked Valves
ML19209C189
Person / Time
Site: Calvert Cliffs  
Issue date: 08/17/1979
From: Lundvall A
BALTIMORE GAS & ELECTRIC CO.
To: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19209C187 List:
References
NUDOCS 7910120170
Download: ML19209C189 (2)


Text

.. ?

B ALTIMORE G AS AND ELECTRIC COMP ANY P.O. BO X 14 7 5 B A LTIM O R E. M A R YL A N D 2120 3 ARTHun E. LUN OVALL,.JR.

vics Pass osae Suppsv August 17, 1979 Office of Inspection and Enforcement Docket Nos. 50-317 U.S. Nuclear Regulatory Commission 50-318 Region I 631 Park Avenue King of Prussia, Pennsylvania 19406 Attention:

Mr. Boyce H. Grier, Director Gentlemen:

This refers to your Inspection Report 50-317/79-07; 50-318/79-06 of August 8, 1979, which transmitted one item of non-compliance noted during the inspection. Enclosure (1) to this letter constitutes a written explanation in reply to this item of non-compliance.

Should you have further questions concerning this reply, we would be pleased to discuss them with you.

Very truly yours[

f.

t & c id c m

/

A. E. L: ndVail, Jr.

Vice President - Supply AEL/ RED /dds Enclosure

)'

) b0 7910120'

r-

?

ENCLOSURE (1)

REPLY TO APPENDIX A 0F NRC LETTER OF AUGUST 8, i Ql:, REGARDING IE INSPECTIONS 50-317/79-07 AND 50-318/79-06 As stated at the inspection exit interview and set forth by paragraph 3.C of " Details" in the inspection report, a new monthly Surveillance Test Procedure has bcen issued (on June 1,1979) which requires that all locked valves associated with the locked valve list of the " Pre-Startup Checkoff" procedure which are accessible during plant operation are phytically checked to be in the correct position.

In addition, the procedure requires a check of the valve locking device and the green /

red tags which indicate required position. Formerly, th: e was no requirement to check the position of these valves except when returning from a Cold Shutdown condition; the issuance of the new Surveillance Test Procedure substantially increases the assurance that these valves remain in their prescribed position and that the locking devices and tags remain installed.

To more positively insure the proper positioning of locked valves prior to returning from a Cold Shutdown condition, the Nuclear Plant Engineer-Operations issued Standing Instruction 79-4 on June 20, 1979, which requires that locked valve line-ups be performed twice by separate individuals. This measure should significantly reduce the possibility of human errors causing incorrect valve positioning, i'

i 170