Forwards IE Circular 79-18, Proper Installation of Target Rock Safety Relief Valves. No Action Required
ML19208B681
Person / Time
Site: Crystal River 
Issue date: 09/10/1979
From: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Stewart W
FLORIDA POWER CORP.
References
NUDOCS 7909210182
Download: ML19208B681 (1)


Text

-

f/[L

/

UNITED STATES

.gQ "po 8

NUCLEAR REGULATORY COMMISSION

~

o

(

3

. e REGION II e

%,*****.,8[

101 MARIETTA ST., N.W., SulTE 3100 ATLANTA, GEORGIA 30303 SEP 1 0 1979 In Reply Refer To:

RII:JPO 50-302 k

Florida Power Corporation Attn:

W. P. Stewart, Manager Nuclear Operations P. O. Bos. 14042, Mail Stop C-4 St. Petersburg, Florida 33733 Gentlemen:

The enclosed Circular No. 79-18 is forwarded to you for information. No written response is required.

Should you have any questions related to your understanding of the recommendations on this matter, please contact this office.

2 Sincerely,

-(

James P. O'Reill Director

Enclosures:

1.

IE Circular No. 79-18 2.

List of IE Circulars issued in the last six months 386.ihis 7909210[ [ &

/)

SEP 1 0 1979 Florida Power Corporation.

cc w/ encl:

G. P. Beatty, Jr.

Nuclear Plant Superintendent Post Office Box 1240 Crystal River, Florida 32629 k.

.m

  • 9

Accession No: 7908200385 SSINS No. 6830 UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 September 10, 1979 IE Circular No. 79-18 PROPER INSTALLATION OF TARGET ROCK SAFETY-RELIEF VALVES Description of Circumstances:

As a result of NRC monitoring of operating experiences involving the Target Rock safety-relief valve, two potential problems have been identified. One potential problem is that the performance of the valve has been found to be impaired by either excessive or insufficient insulation around the valve body when installed in its service environment. The other potential problem is that improper assembly of the modified valve can result in inoperability of the remote air actuator.

The Target Rock safety-relief valve is a dual purpose valve in that overpressure response is provided by pilot valve action and automatic depressurization (ADS) is provided by a remote air actuator. Valve operation has been found to be affected by the amount of insulation placed around the valve body. A previous IE 1.u11etin No. 76-06 was issued on July 21, 1976 as a result of operating ( geriences where excessive insulation was installed on the valve.

The excessive insulation caused excessive heat to be retained producing a higher temperature environment for the elastomeric diaphragm which resulted in accelerated deterioration of the elastomer. Failure of the elastomeric diaphragm, makes the valve inoperable in the power-operation mode (i.e. manual and 85).

Subsequently, a silicone-nomex diaphragm was developed by the manufacturer to provide a longer life in high temperature environments.

In addition, the IE Bulletin explicitly required that insulation be installed in accordance with the manufacturer's recommendations.

A recent licensee event report from the Monticello facility identified a potential problem resulting from insufficient insulation (i.e. just opposite of the condition addressed by 1E Bulletin 76-06). During the performance of special testing of the response to safety-relief valve operation, a valve was discovered to be exceeding its design delay time for opening.

Subsequent inspection and testing of the valve revealed that insufficient insulation may cause condensation to accumulate in the pressure venting ports which then results in delaying the opening of the main disk. This slower response time is significant with respect to primary system overpressure and similar transient response analyses. Although the reported event at Monticello involved the three-stage Target Rock safety-relief v ves the re uirements for reper amounts of insulation are similarly applicable valves.

DUPLICATE DOCUMENT o g.J a.;'b" "?3 a

The second potential problem was recen Entire document previously entered The licensee event report indicated th into system under:

design two-stage valve resulted in pre ANO ThCDOO366 INo.ofpages:

4