Forwards IE Bulletin 79-14,Suppl 1, Seismic Analysis for As-Built Safety-Related Piping Sys. Action Required
ML19207B554
Person / Time
Site: San Onofre  
Issue date: 08/15/1979
From: Engelken R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To: Moorej B
SOUTHERN CALIFORNIA EDISON CO.
References
NUDOCS 7908300245
Download: ML19207B554 (1)


Text

.

fj UNITED STATES

((b y

g NUCLEAR REGULATORY COMMISSION r,.

.J REGION V S,

8 1990 N. CALIFORNIA BOULEVARO

,d StJITE 202, WALNUT CREEK PLAZA WALNUT CREEK, CALIFORNIA 94596 August 15, 1979 Docket Nos. 50-361 50-362 Southern California Edison Company P. O. Box 800 2244 Walnut Grove Avenue

~

Rosemead, California 91770 Attention: Mr. J. B. Moore Vice President Gentlemen:

The enclosed supplement to Bulletin 79-14 is forwarded to you to provide added guidance on the intent of the Bulletin.

If you desire additional information regarding this matter, please contact this office.

Sincerely, (77%g edCi'-

R. fl. Engelken Director

Enclosure:

Supplement IE Bulletin No. 79-14 cc w/ enclosure:

J. H. Drake, SCE 852 349 7 9083 00'Plf

SSIUS:

6320 Accession No:

E 30003G0 UNITED STATES NUCLEAR REGULATORY CORiISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 August 15, 1979 Supplement IE Bulletin No. 79-14 SEISMIC ANALYSIS FOR AS-CuiLT SAFETY-RELATED PIPING SYSTEMS Discription of Circumstances:

IE Buliecin lio. 73-14 was issusc cn July 2,1973 and revised on July 18, 1979.

The bulletin requested licensees to take certain actions to verify that seismic

~

analyses are applicable to as-built plants.' This supplement to the bulletin provides additional guidance and definition of Action Itens 2, 3, and 4.

To comply with the requests in IE Bulletin 79-14, it will be necessary for licensees to do the following:

2.

Inspect Part of the Accessible Piping For each system selected by the licensee in accordance with Item 2 of the Bulletin, the licensee is exoected to verify by physical inspection, to the extent practicable, that the inspection elements neet the acceptance criteria.

In performing these inspectons, the licensee is expected to use measuring techniques of sufficient accuracy to demonstrate that acceptance criteria are net. Where inspection elements important to the seismic analysis cannot be viewed because of thermal insulation or locatien of the piping, the licensee is expected to remove thermal insulation or provide access. Where physical inspection is not practicable, e.g., for valve weights and materials of construction, the license is expected to verify conformance by inspection of quality assurance records.

If a nonconformance is found, the licensee is expected in accordance with Item 4 of the Bulletin to perform an evaluation of the significance of the nonconformance as rapidly as possible to detemine whether or not the operability of the system night be jeopardized during a safe shutdown earthquake as defined in the Regulations.

This evaluation is expected to be done in two phases involving an initial engineering judgement (within 2 days), followed by an analytical engineering evaluation (within 30 days). Where either phase of the evaluation shows that system operability is in jeopardy, the licensee is expected to meet the applicable technical specification action statement and complete the inspections required by Item 2 and 3 of the Bulletin as soon as possible.

The licensee must report the results of these inspections in accordance with the require-rent i for content and schedule as given in Item 2 and 3 of the Bulletin.

3.

Inspect Remaining Piping The licensee is expected to inspect, as in Item 2 above, the remaining safety-related piping systems which were seismically analyzed and to report the results in accordance with the requirements for content and schedule as given in Iten 3 of the Bulletin.

rg 3}Q 7908080360

Sucolement IE Bulletin No. 79-14 Page 2 of 2 August 15, 1979 4A.

Evaluate tionconformances With regard to Item 3A for the Bulletin, the licensee is expected to include in the initial engineering judgement his justification for continued reactor operation.

For the analytical engineering evaluation, the licensee is expected to perform the. evaluation by using the same analytical technique used in the seismic analysis or by an alternate, less complex tecnnique provided tnat tne licensee can show that it is conservative.

If either part of the evaluation shows that the system may not perform its intended function during a design basis earthquake, the licensee must promptly comply with applicable action statements and reporting requirements in the Technical Specifications.

4B.

Submit ilonconformance Evaluations The licensee is expected to submit evaluations of all nonconformances and, where the licensee concludes that the seismic analysis may not be conservative, submit schedules for reanalysis in accordance with Iten 4B of the Bulletin or correct the noncomformances.

4C.

Correct flanconformances If the licensee elects to con ?ct nonconformances, the licensee is expected to submit schedules work descriptions in accordance with Item 4C of the Bulletin.

40.

Improve Oualtiy Assurance If nonconformances arc identified, the licensee is expected to evaluate and improve quality assurance procedures to assure that future modifica-tions are handled efficiently.

In accordance with Item 40 of the Bulletin, the licensee is expected to revise design documents and seismic analyses in a timely manner.

The schedule for the action and reporting requirements given in the Bulletin as originally issued remains unchanged.