Data sheet WDS Multiflex

ENGLISH Description WDS MultiFlex mats grade ST and HT are engineered 3D flexible microporous insulation products offering extremely low and flat thermal conductivity values in a wide temperature range, hence providing outstanding insulating performances which are up to five times better than any other conventional insulator, together with excellent thermal stability up to 1050°C (1922°F).

WDS MultiFlex uses WDS Technology, which is the benchmark in microporous know-how: it is today the only available technology that allows to perfectly and consistently control and engineer both the texture and the distribution of the microporous mineral matrix core in order to obtain superior thermal characteristics but with improved mechanical properties overall.

WDS MultiFlex core is a composition of reinforced blend of opacified premium grade inorganic silicates available in different property formulations; this homogeneous mineral matrix is then covered with an outer envelope which may be either glass (ST grade) or stabilized amorphous silica (HT grade) cloths to enable fast and clean manipulation; the stitched grid guarantees the necessary flexibility and twisting properties.

WDS super-insulation is the definitive answer to any of your most demanding thermal insulation concerns when seeking for space and weight reduction together with effective energy savings in a very wide temperature spectrum.

WDS MultiFlex complies with the standard specification for microporous insulation ASTM C1676.

WDS MultiFlex products are non-flammable in accordance to DIN EN 13501-1, Euroclass A1.

Advantages l Twist & Flex type of insulation for best accessibility of complex geometries or in limited space l Ultra-thin microporous insulation saves space & weight on apparels, equipment and transportation units l Remarkable low and flat thermal conductivity l Inorganic and non combustibile l High operating temperature limit with negligible shrinkage l Easy and fast handling, installation and fixing l Optimal for warehousing and logistic saving, high packing density l Easy to cut and preform in complex shapes l Homogeneous, compact and robust matrix core l High performance insulation proven effective up to 5 times better than conventional insulators Thanks to an exclusive manufacturing process developed by Porextherm Engineering Department, WDS MultiFlex mats feature exceptional homogeneity and perfect distribution of the mineral matrix texture resulting in superior consistency and perfect handling ability and workability to any other known similar product; in addition because of its homogeneity in density and texture distribution, the insulating properties are constantly equal all over the surface of the mats resulting in lower thermal conductivity values.

The squared edges of WDS MultiFlex mats, another unique characteristic offered by Porextherm, also allow tighter sealing joints from one panel to another, minimizing gaps, thus reducing thermal bridges and consequent heat loss.

Furthermore, the core density can be tailored to specific requirements and needs in order to provide specific insulating property results and desired compression resistance.

WDS MultiFlex flexible insulation mats are the best choice when wide ranges of application temperatures are involved and the lowest thermal conductivity together with a perfect thermal integrity over time is required.

Safety directions WDS MultiFlex core material is not a hazardous material as defined in EU directive 2006/1907/EEC. The fibers used for mechanical reinforcement of WDS MultiFlex core material are not respirable as defined by WHO.

WDS MultiFlex core material does not liberate hazardous decomposition products and, as far as is known at present, does not cause any problems to human health.

The data published is in accordance with the present state of our knowledge, but does not absolve the user from carefully checking all supplies immediately on receipt. We reserve the right to alter product constants within the scope of technical progress or new developments. The recommendations made in this leaflet should be checked by preliminary trials because of conditions during processing over which we have no control, especially where materials from other companies are involved. The recommendations do not absolve the user from the obligation of investigating the possibility of infringement of third parties rights and, if necessary, clarifying the position. Recommendations for use do not constitute a warranty, either express or implied, of the fitness or suitability of the product for a particular purpose.

www.morganthermalceramics.com www.porextherm.com Metric information - Page 2 Imperial information - Page 3

© 2016 Thermal Ceramics, a business of Morgan Advanced Materials 08/12/2016 Page 1 of 3

Standard specifications 2D50 3D50 2D25 3D25 Standard dimensions (core panel), mm (further thicknesses and dimensions on demand) 1200 x 1000 x (8, 10, 12, 12,5) (only available for ST version) 1000 x 500 x (5, 6, 8,10, 12, 12,5) 500 x 500 x (5, 6, 8,10, 12, 12,5) 500 x 250 x (5, 6, 8,10, 12, 12,5)

Stitching direction Longitudinal or Aslant Longitudinal and Aslant Longitudinal or Aslant Longitudinal and Aslant Stitching space, mm 50 50 x 50 25 25 x 25 Tolerances according to DIN ISO 2768, tolerance class "C-course", mm

> 30:

+/- 0.5

> 30 -120:

+/- 0.8

> 120 - 400:

+/- 1.2

> 400 - 1000:

+/- 2.0

> 1000 - 2000:

+/- 3.0 Physical Properties ST Grade HT Grade Classification temperature (°C) 1000 1050 Textile covering E-glass Amorphous silica Nominal density (core) (kg/m³)

210 280 Cold compressive strength at room temperature ASTM C 165 (N/mm²)

1-3 1-3 Thermal conductivity at mean temperature of:

ASTM C 177 W/mK

@200°C 0.025 0.028

@400°C 0.03 0.035

@600°C 0.038 0.043

@800°C 0.049 0.06 Specific heat capacity (Kj/Kg K)

@400°C 1.05 1.05 Shrinkage with temperature applied to one side, %

@800°C 0.03

@1000°C 0.05 Linear shrinkage with temperature applied to all sides, 24hrs, %

@800°C 1

@1000°C 2

Data sheet WDS Multiflex

Metric information www.morganthermalceramics.com www.porextherm.com

© 2016 Thermal Ceramics, a business of Morgan Advanced Materials 08/12/2016 Page 2 of 3

  • Pure core tested under ASTM C177, given values are extrapolated by both mathematical calculation and lab simulations.

Safety directions: WDS MultiFlex is not a hazardous material as defined in EU directive 2006/1907/EEC. The fibers used for mechanical reinforcement of WDS MultiFlex are not respirable as defined by WHO. WDS MultiFlex does not liberate hazardous decomposition products and, as far as is known at present, does not cause any problems to human health.

The data published is in accordance with the present state of our knowledge, but does not absolve the user from carefully checking all supplies immediately on receipt. We reserve the right to alter product constants within the scope of technical progress or new developments. The recommendations made in this leaflet should be checked by preliminary trials because of conditions during processing over which we have no control, especially where materials from other companies are involved. The recommendations do not absolve the user from the obligation of investigating the possibility of infringement of third parties rights and, if nessary, clarifying the position. Recommendations for use do not constitute a warranty, either express or implied, of the fitness or suitability of the product for a particular purpose.

Contact Europe:

Telephone:

+44 (0) 151 334 4030 E-mail:

marketing.tc@morganplc.com North America:

Telephone:

+1 (706) 796 4200 E-mail:

northamerica.tc@morganplc.com South America:

Telephone:

+54 (11) 4373 4439 E-mail:

marketing.tc@morganplc.com Asia:

Telephone:

+65 6595 0000 E-mail:

asia.mc@morganplc.com Porextherm:

Porextherm Dmmstoffe GmbH Heisinger Strae 8/10 D-87437 Kempten Telephone:

+ 49 (0)831 - 575360 Fax:

+ 49 (0)831 - 575363 The data presented in this leaflet are in accordance with the present state of our knowledge, but do not absolve the user from carefully checking all supplies immediately on receipt. We reserve the right to alter product constants within the scope of technical progress or new developments. The recommendations made in this leaflet should be checked by preliminary trials because of conditions during processing over which we have no control, especially where other companies raw materials are also being used. The recommendations do not absolve the user from the obligation of investigating the possibility of infringement of third parties rights and, if necessary, clarifying the position.

Recommendations for use do not constitute a warranty, either express or implied, of the fitness or suitability of the product for a particular purpose.

Whilst the values and application information in this datasheet are typical, they are given for guidance only. The values and the information given are subject to normal manufacturing variation and may be subject to change without notice. Morgan Advanced Materials - Thermal Ceramics makes no guarantees and gives no warranties about the suitability of a product and you should seek advice to confirm the products suitability for use with Morgan Advanced Materials - Thermal Ceramics.

Morgan Advanced Materials plc Registered in England & Wales at Quadrant, 55-57 High Street, Windsor, Berkshire SL4 1LP UK Company No. 286773

Imperial Information Physical Properties ST Grade ST Grade Classification temperature (°F) 1832 Textile Covering Glass Nominal density (core) (pcf) 13.1 Cold compressive strength at room temperature ASTM C 165 (psi) 60.48 Thermal conductivity at mean temperature of: ASTM C 177 (BTUin./hrft2°F)

@392°F 0.173

@752°F 0.208

@1112°F 0.263

@1472°F 0.340 Specific heat capacity (BTU/lb°F)

@752°F 0.226 Shrinkage with temperature applied to one side (%)

@1832°F 0.6 Linear shrinkage with temperature applied to all sides, 24hrs (%)

@1472°F 1.4 Imperial information www.morganthermalceramics.com www.porextherm.com

© 2016 Thermal Ceramics, a business of Morgan Advanced Materials 08/12/2016 Page 3 of 3 The above data is only intended as a guide and should not be used in preparing specifications.

Data sheet WDS Multiflex

Imperial Information Standard specifications 2D50 3D50 2D25 3D25 Standard dimensions (core panel) (in) 47.24 x 39.37 x (0.39, 0.49) 39.4 x 19.7 x (0.20, 0.24, 0.31, 0.39, 0.49)

Stitching direction Horizontal or vertical Horizontal and vertical Horizontal or vertical Horizontal and vertical Stitching space (in) 1.97 1.97 x 1.97 0.98 0.98 x 0.98

  • Pure core tested under ASTM C177, given values are extrapolated by both mathematical calculation and lab simulations.

Safety directions:Firemaster WDS MarineFlex is not a hazardous material as defined in EU directive 2006/1907/EEC. The fibers used for mechanical reinforcement of WDS MarineFlex are not respirable as defined by WHO.

The data published is in accordance with the present state of our knowledge, but does not absolve the user from carefully checking all supplies immediately on receipt. We reserve the right to alter product constants within the scope of technical progress or new developments. The recommendations made in this leaflet should be checked by preliminary trials because of conditions during processing over which we have no control, especially where materials from other companies are involved. The recommendations do not absolve the user from the obligation of investigating the possibility of infringement of third parties rights and, if necessary, clarifying the position. Recommendations for use do not constitute a warranty, either express or implied, of the fitness or suitability of the product for a particular purpose.

Contact Europe:

Telephone:

+44 (0) 151 334 4030 E-mail:

marketing.tc@morganplc.com North America:

Telephone:

+1 (706) 796 4200 E-mail:

northamerica.tc@morganplc.com South America:

Telephone:

+54 (11) 4373 4439 E-mail:

marketing.tc@morganplc.com Asia:

Telephone:

+65 6595 0000 E-mail:

asia.mc@morganplc.com Porextherm:

Porextherm Dmmstoffe GmbH Heisinger Strae 8/10 D-87437 Kempten Telephone:

+ 49 (0)831 - 575360 Fax:

+ 49 (0)831 - 575363 The data presented in this leaflet are in accordance with the present state of our knowledge, but do not absolve the user from carefully checking all supplies immediately on receipt. We reserve the right to alter product constants within the scope of technical progress or new developments. The recommendations made in this leaflet should be checked by preliminary trials because of conditions during processing over which we have no control, especially where other companies raw materials are also being used. The recommendations do not absolve the user from the obligation of investigating the possibility of infringement of third parties rights and, if necessary, clarifying the position.

Recommendations for use do not constitute a warranty, either express or implied, of the fitness or suitability of the product for a particular purpose.

Whilst the values and application information in this datasheet are typical, they are given for guidance only. The values and the information given are subject to normal manufacturing variation and may be subject to change without notice. Morgan Advanced Materials - Thermal Ceramics makes no guarantees and gives no warranties about the suitability of a product and you should seek advice to confirm the products suitability for use with Morgan Advanced Materials - Thermal Ceramics.

Morgan Advanced Materials plc Registered in England & Wales at Quadrant, 55-57 High Street, Windsor, Berkshire SL4 1LP UK Company No. 286773