Prepared Checked Released S. Fels M. Hennebach F. Hilbert 23.07.2019 23.07.2019 23.07.2019 0023-BAW-2019-001-Rev0.docx 1 / 6 Geistiges Eigentum der DAHER NUCLEAR TECHNOLOGIES GmbH - Vervielfltigung oder Weitergabe nur mit ausdrücklicher Zustimmung.
Property of DAHER NUCLEAR TECHNOLOGIES GmbH - Reproduction not permitted.
Change Report Licensing of an alternative supplier for the thermal insulation layer of the DN30 PSP 0023-BAW-2019-001-Rev0
0023-BAW-2019-001-Rev0 2 / 6 Geistiges Eigentum der DAHER NUCLEAR TECHNOLOGIES GmbH - Vervielfltigung oder Weitergabe nur mit ausdrücklicher Zustimmung.
Property of DAHER NUCLEAR TECHNOLOGIES GmbH - Reproduction not permitted.
Table of Contents 1
Introduction....................................................................................................................... 3 2
Comparison of WDS Multiflex to MICROTHERM............................................................. 3 3
Impact of the Thermal Insulation Layer of the DN30 PSP with Respect to the Safety Analysis for the DN30 Package........................................................................................ 4 3.1 Structural Analysis........................................................................................................ 4 3.2 Thermal Analysis.......................................................................................................... 4 3.3 Containment Analysis................................................................................................... 5 3.4 External Dose Rate Analysis........................................................................................ 5 3.5 Criticality Analysis......................................................................................................... 5 4
Summary............................................................................................................................ 5 Literature................................................................................................................................... 6
0023-BAW-2019-001-Rev0 3 / 6 Geistiges Eigentum der DAHER NUCLEAR TECHNOLOGIES GmbH - Vervielfltigung oder Weitergabe nur mit ausdrücklicher Zustimmung.
Property of DAHER NUCLEAR TECHNOLOGIES GmbH - Reproduction not permitted.
1 Introduction The DN30 Protective Structural Packaging (DN30 PSP) is designed for the transport of 30B cyl-inders containing commercial grade uranium or reprocessed uranium with an enrichment of not more than 5 wt.% U-235 in uranium.
This report aims to include an alternative supplier for the thermal insulation material of the DN30 PSP in its certificate of approval. Supply difficulties or other circumstances may require using an alternative supplier than the currently certified supplier Promat providing the MI-CROTHERM (Overstitched 1000R HY) [1] thermal insulation material.
In this report, it is shown that MICROTHERM can be replaced with WDS Multiflex (ST Grade) [2]
by the supplier Morgan Advanced Materials. Therefore, the impact of the material for the thermal insulation is discussed with respect to the package design safety report for the package design DN30 [3] hereafter in chapter 2. It is shown that WDS Multiflex has similar or improved properties compared to MICROTHERM.
2 Comparison of WDS Multiflex to MICROTHERM MICROTHERM [1] and WDS Multiflex [2] are both custom made flexible microporous insulation panels with very good thermal properties. They provide excellent thermal stability up to more than 1000 °C. Both panels are produced in a glass cloth outer envelope, making them clean and easy to handle. The stitched grid guarantees the necessary flexibility and twisting properties. Finally, a hydrophobic version is available of both materials as well. Table 2-1 summarizes some of the properties of MICROTHERM and WDS Multiflex. Further details on both materials are provided in the technical data sheets [1] and [2], respectively.
Table 2-1: Comparison of MICROTHERM and WDS Multiflex MICROTHERM (Overstitched 1000R HY)
WDS Multiflex (ST Grade)
E-glass as standard finishing E-glass as textile covering Custom made + flexible Twist & Flex type of insulation Extremely low thermal conductivity Remarkable low and flat thermal conductivity High thermal stability High operating temperature limit with negligi-ble shrinkage Shock + vibration resistant Homogeneous, compact and robust matrix core Environmentally friendly, free of organic bind-ers and non-combustible Inorganic and non-combustible Clean & easy to install Easy and fast handling, installation and fixing Simple to cut & shape Easy to cut and preform in complex shapes Available in different temperature grades, in-cluding a hydrophobic version Available in two temperature grades, includ-ing a hydrophobic version No harmful respirable fibers Fibers used for mechanical reinforcement are not respirable Resistant to most chemicals Core material does not liberate hazardous decomposition products
0023-BAW-2019-001-Rev0 4 / 6 Geistiges Eigentum der DAHER NUCLEAR TECHNOLOGIES GmbH - Vervielfltigung oder Weitergabe nur mit ausdrücklicher Zustimmung.
Property of DAHER NUCLEAR TECHNOLOGIES GmbH - Reproduction not permitted.
3 Impact of the Thermal Insulation Layer of the DN30 PSP with Respect to the Safety Analysis for the DN30 Package 3.1 Structural Analysis In the calculation model used for the structural analysis of the DN30 package, the thermal insu-lation layer is not explicitly represented. The thermal insulation layer has been included in a later development stage of the DN30 PSP and a small fraction of the impact limiting foam between the foam and the inner shells of the DN30 PSP needed to be removed to be able to include the thermal insulation layer. As the compression strength of the MICROTHERM thermal insulation layer is lower than that of the foam, the covering assumption has been made in a subsequent analysis to reduce the foam thickness by the thickness of the thermal insulation layer without filling the resulting gap with MICROTHERM. In addition to this analysis, real tests with a prototype including the thermal insulation layer have been performed. Both in the simulations and the real tests, the deformations were very similar to simulations and tests with prototypes not including the thermal insulation layer.
Consequently, with respect to the structural analysis, the only requirement of a thermal insulation material from another supplier is a compression strength that is equal to or higher than that of MICROTHERM. With this requirement, the compression of the thermal insulation layer can be expected to be similar or reduced compared to the application of MICROTHERM. This require-ment is mandatory with respect to the thermal test. The technical data sheets of MI-CROTHERM [1] and WDS Multiflex [2] provide minimal compression strengths of 0.12 MPa and 1 MPa, respectively. Thus, the above requirement is fulfilled in case of WDS Multiflex.
3.2 Thermal Analysis As the thermal insulation layer is included in the thermal analysis of the DN30 package [3], a new thermal analysis was conducted using the alternative material WDS Multiflex [2]. The material properties of both insulating materials are given in Table 3-1 and are taken from [1] and [2], re-spectively.
Table 3-1: Material Properties for the Thermal Analysis Temperature in °C MICROTHERM WDS Multiflex Density in kg/m³ 260 210 Thermal conductivity in W/(m*K) 200 0.026 0.025 400 0.030 0.030 600 0.038 0.038 800 0.049 0.049 Heat capacity in J/(kg*K) 200 920 1050 400 1000 1050 1) 600 1040 1050 800 1080 1050
- 1) Value given in [2] for 400 °C is assumed for the whole temperature range.
0023-BAW-2019-001-Rev0 5 / 6 Geistiges Eigentum der DAHER NUCLEAR TECHNOLOGIES GmbH - Vervielfltigung oder Weitergabe nur mit ausdrücklicher Zustimmung.
Property of DAHER NUCLEAR TECHNOLOGIES GmbH - Reproduction not permitted.
The calculation for the evaluation of the alternative thermal insulation material is done according to the IAEA/ADR-guidelines for accident conditions of transport (ACT). These conditions consider a fire accident with a temperature of 800 °C lasting for 1800 s. The complete boundary conditions for the thermal analysis, including the material properties for other materials used in the calculation model, allowable temperatures for the package, heat generation, solar insolation and heat transfer in gaps and to the ambient, are listed in detail in the package design safety report [3].
The maximum temperatures calculated with both thermal insulation materials are listed in Ta-ble 3-2 below, including the time after the beginning of the fire when the highest temperatures are reached.
Table 3-2: Maximum Temperatures Calculated for the DN30 Package Location MICROTHERM WDS Multiflex Temperature in °C Time in s Temperature in °C Time in s 30B cylinder valve 122.4 12710 121.7 12710 30B cylinder plug 120.6 10910 119.9 10910 30B cylinder mantle 124.7 10310 124.0 10310 DN30 inner shell 187.7 3650 187.9 3650 DN30 outer shell 785.4 1810 785.4 1810 The new thermal analysis proves that the maximum temperatures for critical components are nearly identical with differences of less than 1 °C. The maximum temperatures calculated with the alternative material for the thermal insulation are slightly lower. Consequently, considering the thermal analysis, WDS Multiflex has even better properties than MICROTHERM.
3.3 Containment Analysis The thermal insulation layer is not considered in the containment analysis as the containment system is entirely made up by the 30B cylinder. Any alternative material for the thermal insulation layer will not have an impact on this part of the safety analysis for the DN30 package.
3.4 External Dose Rate Analysis The external dose rate analysis under routine conditions of transport (RCT) and normal conditions of transport (NCT) will not be affected as well since the thermal insulation layer is not explicitly considered in the calculation model. Instead, a covering assumption has been made by assuming a density of 0.1 g/cm³ for the foam, which has a nominal density of 0.12 g/cm³. This assumed density of 0.1 g/cm³ covers both the density of MICROTHERM (0.26 g/cm³) and WDS Multiflex (0.21 g/cm³) with a large margin. Consequently, the analysis of the external dose rate covers this alternative material for the thermal insulation.
3.5 Criticality Analysis The thermal insulation layer is not relevant for the criticality analysis as only the 30B cylinder and the steel shells of the DN30 PSP are considered in the covering criticality calculation model.
Hence, changes to the thermal insulation layer will not have an impact on this analysis as well.
4 Summary In this report, it has been shown that WDS Multiflex by Morgan Advanced Materials [2] can be used as an alternative material for MICROTHERM provided by Promat [1]. The impact on all safety analyses performed for the DN30 package has been considered. As the thermal analysis is most affected by using a different material for the thermal insulation, a variation calculation has
0023-BAW-2019-001-Rev0 6 / 6 Geistiges Eigentum der DAHER NUCLEAR TECHNOLOGIES GmbH - Vervielfltigung oder Weitergabe nur mit ausdrücklicher Zustimmung.
Property of DAHER NUCLEAR TECHNOLOGIES GmbH - Reproduction not permitted.
been performed to investigate the impact. This variation calculation proves that the impact is neg-ligibly small and that WDS Multiflex can be used without lowering the safety of the DN30 package.
For the structural, containment, external dose rate and criticality analysis, the thermal insulation layer is not considered. Consequently, using a different material for the thermal insulation layer does not affect these analyses at all.
Literature
[1]
Promat Technical Data Sheet - MICROTHERM OVERSTITCHED
[2]
Morgan Advanced Materials Technical Data Sheet - WDS Multiflex
[3]
DAHER NUCLEAR TECHNOLOGIES GmbH Package Design Safety Report for Package Design DN30 0023-BSH-2016-001, Rev3, 2018