SBK-L-19052, Steam Generator Tube Inspection Report

From kanterella
(Redirected from ML19109A214)
Jump to navigation Jump to search

Steam Generator Tube Inspection Report
ML19109A214
Person / Time
Site: Seabrook 
Issue date: 04/19/2019
From: Browne K
NextEra Energy Seabrook
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
SBK-L-19052
Download: ML19109A214 (24)


Text

NEXTera ENERGY~

April 19, 2019 SBK-L-19052 Docket No. 50-443 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001 Seabrook Station Steam Generator Tube Inspection Report SEABROOK Enclosed is the Seabrook Station Steam Generator Tube Inspection Report. NextEra Energy Seabrook, LLC is submitting this report in accordance with Seabrook Station Technical Specification 6.8.1.7, Steam Generator Tube Inspection Report. This repmi provides the results of the steam generator tube inspections conducted during refueling outage 19 in the Fall of 2018.

This letter contains no new regulatory commitments.

If you have any questions regarding this submittal, please contact me at ( 603) 773-7932.

Sincerely, Licensing Manager Enclosure cc:

NRC Region I Administrator R. Gladney, NRC Project Manager NRC Senior Resident Inspector NEXTERA ENERGY SEABROOK, LLC, P.O. Box 300, LAFAYETIE ROAD, SEABROOK, NH 03874

Enclosure Steam Generator Tube Inspection Report

Enclosure OR19 Steam Generator Tube Inspection Report

==

Introduction:==

The enclosed Steam Generator Tube Inspection Report for Seabrook Unit 1 is submitted for the inspection of the SGs during refueling outage 19 (hereafter referred to as the OR19 inspection or outage), as required by Technical Specification section 6.8.1.7. Per the Seabrook Unit 1 Technical Specification section 6.7.6.k, the first ISI period is 120 EFPM; the second ISI period is 96 EFPM; the third and subsequent inspection periods are 72 EFPM. The inspection in OR19 was performed in accordance with Technical Specification 6.7.6.k, and was the last inspection of the SGs in the third ISI period. At unit shutdown for the OR19 inspection, the SGs had operated for approximately 24.56 EFPY (294.8 EFPM) since installation. This included operation for approximately 1.41 EFPY (16.9 EFPM) during the fuel cycle (cycle 19) leading up to the OR19 inspection. Initial entry into Mode 4 following completion of the OR19 inspection was made on October 24, 2018.

Seabrook Unit 1 is a Westinghouse 4-loop PWR with Model F steam generators. The SGs are U-tube heat exchangers with tube bundles fabricated using thermally treated Alloy 600 tubing. Each SG contains 5,626 tubes arranged in 59 rows and 122 columns. Nominal tube OD is 0.688" with a 0.040" nominal wall thickness. The tubes have a square pitch arrangement and are supported by stainless steel, broached-hole, quatrefoil tube support plates (TSPs). The inspection of the SGs during the OR19 outage met the requirements of the Seabrook Unit 1 Technical Specifications and the EPRI SGMP: PWR Steam Generator Examination Guidelines, Revision 8.

References to Seabrooks prior SG Tube Inspection Reports in the third inspection period are tabulated in Appendix A along with a list of acronyms used in this report. Appendix B provides a list of imperfections (non-SCC indications).

A. Scope of Inspections Performed on each SG The inspection scope for OR19 met the requirements of Seabrook Unit 1 Technical Specification 6.7.6.k.d. For all sample inspections, tube selection priority was given to the ones not inspected in OR17 to meet the sequential period requirements in Technical Specifications. Unless otherwise noted, the defined OR19 base inspection scope in all 4 SGs was:

Primary-side:

  • 100% full-length bobbin probe examination of all active tubes except U-bends of Rows 1 and 2.
  • 50% of U-bends of Rows 1 & 2 using the +Point' probe.
  • Peripheral tubes (3 outermost tubes of each row) exposed to the annulus, and 2 rows of tubes in the tube-free lane were inspected in the HL and CL using the +Point' probe. The extent was +/- 3 inches in the CL and +3 inches above the TTS to the H* depth (-15.21 in.) in the HL.
  • 50% sample of non-peripheral tubes in the HL from +3 inches above the TTS to the H* depth (-15.21 in.) using the +Point' probe, including 50% of the BLG/OXP within the H* depth of the tubesheet.
  • 50% of Dings/Dents > 5V in the HL (freespan, supports), U-bend and uppermost CL TSP (called 08C) using the +Point' probe.
  • +Point' probe inspection of all high stress (minus 2-sigma) tubes at HL & CL TSP locations.
  • 100% +Point' probe inspection at HL TSP locations on non-high stress tubes that have a large noise residual (defined as locations with a vertical maximum noise component of >0.45 volt on the P1 mix channel.
  • Special interest exams based on the results of bobbin coil exams including +Point' probe inspection of all I-codes from bobbin.
  • Visual inspection of all mechanical and welded plugs.

Page 1 of 22

Inspection Expansion:

One PWSCC indication in the HL TTS region of SG-C resulted in an expansion of the inspection to 100%

of tubes in the HL of SG-C from +3 inches above the TTS to the H* depth (-15.21 in.) using the

+Point' probe, per the EPRI SGMP: PWR Steam Generator Examination Guidelines, Revision 8. No inspection expansion was required in the other SGs since the minimum sample size requirement was met by the base scope described above for the HL tubesheet program. Additional details on the PWSCC indication is provided later in the report.

Secondary-side:

  • TTS sludge lancing in all 4 SGs.
  • FOSAR in all 4 SGs. Included TTS in-bundle inspections in each SG.
  • Upper steam drum inspection in SG-D.

B. Degradation Mechanisms Found The following degradation mechanisms were identified during the OR19 inspection:

  • An axial PWSCC indication at the TTS in the HL of SG-C.
  • Wear at AVB contact points.
  • Wear (volumetric) indications at, or above the TTS and at TSPs.
  • Maintenance-related wear at the FDB and in the free span.
  • Foreign object wear Page 2 of 22

C. NDE Techniques utilized for each Degradation Mechanism Table 1a is the list of the EPRI ETSSs used for degradation detection during the OR19 ECT inspection.

Table 1a - NDE Detection Techniques for Degradation Mechanisms Detection probe ETSS used for Detection Degradation Mechanism Location / Applicability Bobbin I96041.1 Rev 5 Wear AVB locations Bobbin 96004.1 Rev 13 Wear TSP and FDB locations Bobbin

+Point 27091.2 Rev 2 21998.1 Rev 4 Wear Due to foreign objects Bobbin 96005.2 Rev 9 Pitting In the freespan and sludge pile Bobbin I-28411 Rev 4 Axial ODSCC At FDBs locations Bobbin I-28412 Rev 4 I-28413 Rev 5 In the freespan Bobbin I-28413 Rev 5 At broached TSPs Bobbin 24013.1 Rev 2 10013.1 Rev 1 At Dents/Dings 5V

+Point 22401.1 Rev 4 96703.1 Rev 17 I-28424 Rev 4 I-28425 Rev 4 At Dents/Dings > 5V

+Point 10411.1 Rev 0 In low row U-bends

+Point 21409.1 Rev 7 I28424 Rev 4 I28425 Rev 4 In the sludge pile/expansion transition

+Point 20511.1 Rev 8 Axial PWSCC At expansion transition 20510.1 Rev 7 Circ PWSCC

+Point 20511.1 Rev 8 I11524 Rev 0 Axial/Circ PWSCC At BLGs/OXPs

+Point 96511.1 Rev 16 96511.2 Rev 16 99997.1 Rev 10 In low row U-bends Table 1b is the list of the EPRI ETSSs used for degradation sizing based on the degradation mechanisms reported during the OR19 ECT inspection.

Table 1b - NDE Sizing Techniques for Degradation Mechanisms Sizing probe ETSS used for Sizing Degradation Mechanism Location / Applicability Bobbin 96004.3 Rev 13 Wear AVB locations

+Point 96910.1 Rev 11 Wear At broached TSP locations

+Point 21998.1 Rev 4 27902.3 Rev 2 27906.3 Rev 1 Wear (volumetric) Due to foreign objects, and caused by legacy sludge lance equipment

+Point 20511.1 Rev 8 Axial PWSCC At expansion transition (for CM purposes)

Page 3 of 22

D. Location, orientation (if linear), and measured sizes (if available) of service induced indications PWSCC:

A single axial indication (SAI) of PWSCC was detected at the TTS expansion transition in SG-C during the HL tubesheet inspection program using the +Point' probe. The indication was found in tube, R33C93, and was characterized as shown in Table 2 below. This tube is not a high stress tube, and there are no bulges or over-expansions (BLG/OXP) at this location. Since the indication was short and shallow by the +Point probe, the location was retested with the Ghent probe, which confirmed the indication. The indication is very similar to the 20% ID axial EDM notch in the ETSS 20511.1 calibration standard. However, when the 100%, 60% and 40% axial ID notches were used to create the sizing calibration curve, the deeper segments on the crack ends are less than one-half the signal amplitude in the center, which is not consistent with basic eddy current theory. Therefore, the indication was more accurately sized by establishing the phase versus depth curve on the 100%, 60%, and 20% axial ID notches (using the 20%

I.D. axial notch instead of the 40% I.D. axial notch) then measuring the depth at the peak amplitude (center) and conservatively assuming that the flaw is uniformly deep over the measured length.

Additional information on the results of condition monitoring for this indication is provided in Section G of this report.

Table 2 - OR19 SCC Indications SG Tube Degradation Mechanism Location ETSS1 Measured Length2 (in.)

Measured Depth2 (%)

Max Volts

(+Point')

C R33C93 PWSCC SAI at TSH+0.04 20511.1 Rev 8 0.21 in.

22%

0.58V

1. ETSS 20511.1, Revision 8 (with the 20% anchoring the low end of the curve instead of the 40% ID axial notch)
2. The structural equivalent length and depth are conservatively assumed equal to the measured length and depth, based on the assumptions made to acquire the crack dimensions using a modified ETSS 20511.1 Appendix B provides a listing for each SG of the tubes with other service-induced indications, showing locations and measured sizes.

AVB Wear:

AVB wear continues to be an existing degradation mechanism in all four SGs at Seabrook. Table 3 summarizes the current inspection results for AVB wear, and the list of AVB indications reported during OR19 are included in Appendix B. In Table 3, the number of indications includes pre-existing and new indications. AVB indications were detected in all 4 SGs, as expected. The highest AVB wear indication was 39% TW. The total number of AVB indications is typical among the population of Model F SGs.

Table 3 - OR19 AVB Wear SG No. of Indications No. of Indications 40% TW New Indications(1)

New Tubes(2)

Number Max Depth SG-A 375 0

21 22% TW 15 SG-B 286 0

14 20% TW 11 SG-C 257 0

14 23% TW 7

SG-D 498 0

25 19% TW 14

1. Includes indications on tubes without prior reported indications
2. Newly-reported with AVB wear with no prior history of AVB indications.

Page 4 of 22

Wear (Volumetric) Indications At or Above the TTS:

Volumetric wear indications reported in OR19 are attributed to: a) maintenance-related (MNT) activity; b) wear at horizontal tube support structures, or c) wear due to transient foreign objects (FOs). Eight newly-reported volumetric indications were detected in OR19: 5 in SG-A and 3 in SG-C. Volumetric indications (VOL, SVI) reported during OR19 are summarized in Table 4.

a) Indications reported in row 1 that are located approximately 18 above the tubesheet or above the FDB plate are attributed to sludge lancing equipment used in the past. The wear indications were caused by interaction of the tubes with the sludge lance rail. One such indication (R1C112 in CL of SG-C) was newly-reported in OR19; however, the signal has been present for several outages without change, and was discernable through noise and reported as NDD in OR17. All other maintenance-related volumetric indications remain essentially unchanged and within inspection technique variabilities from previous inspections.

b) One newly-reported TSP volumetric wear indication was reported in SG-A (R18C82 at 06C). The indication was discernable, but not reported in previous inspections; however, this indication is unchanged. The TSP wear indication in tube R22C97 in SG-B was inspected with +Point' in OR19 and reported a 28% TW, consistent with the 32% TW reported for the OR17 inspection1. All other volumetric wear indications at TSPs remain essentially unchanged from previous inspections.

c) Wear due to impingement of foreign objects on the tubes is categorized as an existing degradation mechanism due to the confirmation of loose parts in the current and prior inspections at Seabrook.

Volumetric wear indications in the following areas are considered to originate from transient foreign objects (loose parts): ones that are at the edge of TSP intersections which are not aligned axially with the land contact point, that reside slightly above or below the TSP, and ones in close proximity to the to TTS. Four foreign object-related VOL indications (not associated with PLPs) were newly-reported in OR19; 2 in SG-A and 2 in SG-C. Two single volumetric indications (SVI) associated with PLPs were also reported in SG-A, and were plugged and stabilized, along with a tube at an adjacent location which also had a PLP signal.

The volumetric indications (Table 4) were all dimensionally sized using qualified ERPI ETSSs for the

+Point' probe. The specific ETSS used for each indication is based on the shape of the flaw from the ECT data; the ones used are listed at the bottom of Table 4.

1 Reference Response to RAI #2 in NRC ADAMS Document Accession No. ML16302A398 Page 5 of 22

Table 4 - OR19 Volumetric Indications SG Row Col Location OR19 Comment A

1 87 TSC+18.85 31% A MNT A

1 36 TSC+18.09 23% A MNT A

1 11 01C-1.68 21% B MNT A

4 87 06C-0.5 9% C TSP A

5 108 06C-0.58 14% C TSP A

18 82 06C-0.62 7% C TSP (newly reported); present in 2009, no change A

21 26 03H-0.64 18% A FO (newly reported), no PLP present (VOL)

A 35 80 03H-0.46 32% A FO A

35 88 03H-0.96 25% A FO A

45 23 01H+0.79 11% B (1)

FO with PLP (SVI). plugged & stabilized A

46 24 01H+0.62 19% B (1) FO w/ PLP (SVI). DSI since 2009. plugged & stabilized A

49 29 TSH+0.16 22% A FO A

50 29 TSH+0.12 14% A FO A

53 33 TSH+0.33 10% A FO VOL (newly reported); no PLP present B

1 11 TSC+18.45 35% A MNT B

1 87 TSH+18.32 39% A MNT B

1 87 TSC+18.32 39% A MNT B

1 112 TSH+18.35 17% A MNT B

1 119 01H+16.16 13% D MNT B

2 98 06C-0.83 35% A FO B

2 113 07H+1.07 27% A FO B

5 86 04H-0.42 14% C TSP B

22 97 05H-0.56 28% C TSP B

43 96 TSH+0.06 19% A FO B

54 87 01C+0.57 19% A FO C

1 87 TSH+17.94 38% A MNT C

1 87 TSC+17.94 11% D MNT C

1 112 TSH+18.36 26% A MNT C

1 112 TSC+18.29 15% A MNT (newly reported); present in 2015, no change C

3 90 07C-0.64 23% A TSP C

3 113 05C-0.80 33% A FO C

5 57 06C-0.64 26% A TSP C

28 104 05C-0.63 25% A FO C

32 24 04H-0.4 27% C TSP C

32 35 07C+19.45 9% A FO C

39 19 TSC+4.05 17% A FO C

42 98 04H-0.8 12% A FO (newly reported), no PLP present; plugged C

43 26 TSH+0.07 24% A FO C

43 98 04H-0.61 27% A FO (newly reported), no PLP present; plugged C

44 26 TSH+0.12 12% A FO D

1 87 TSH+18.42 33% A MNT D

6 108 03H-0.41 10% C TSP D

13 4

01C+0.41 26% A FO D

21 52 04H-0.41 24% A FO D

42 19 03C+0.20 11% C TSP Note: The EPRI ETSSs used for the rotating +Point' probe depth sizing were: A = 21998.1 Volumetric Indications; B = 27902.3 Axial Groove Wear; C = 96910.1 Wear at Tube Supports; D = 27906.3 Tapered Wear Page 6 of 22

Misc. Special Interest Inspections:

Some PLP signals in OR19 had been reported previously, and nearly all of the PLP signals were either historical and not associated with a volumetric indication or were observable by secondary-side FOSAR examination. No damage to the tubes was associated with these PLP signal locations.

[The exceptions were the 2 tubes with SVI indications and the adjacent tube with a PLP signal (no wear)].

Geometric Anomalies: Based on the sample of bulges and over-expansions (BLG/OXP) inspected in OR19, no evidence of any degradation was found. All BLG signals above the TTS were previously-reported in OR17, and no degradation was associated with any of the BLG signals.

No SCC indications were detected during the inspection of high stress tubes at HL and CL TSP locations. SCC was also not reported on non-high stress tubes having large noise residuals.

E. Number of tubes plugged during the inspection outage for each degradation mechanism Six (6) tubes were plugged based on the OR19 inspection; the tubes plugged for each degradation mechanism are summarized below in Table 5:

Table 5 - OR19 Tubes Plugged SG Tube Degradation Mechanism Location Notes A

R45C23 PLP with wear (SVI) 01H+0.71 11% at OR19; stabilizer installed.

R45C24 PLP, no wear 01H+0.36 Preventively plugged due to its proximity to tubes with foreign object wear. Stabilizer installed.

R46C24 PLP with wear (SVI) 01H+0.6 19% in OR19, DSI present from at least 2009.

Stabilizer installed.

C R33C93 SAI (PWSCC)

TSH+0.04 Axial PWSCC at Expansion Transition R42C98 FO Wear, no PLP 04H-0.8 12%TW, no prior history. Preventatively plugged due to proximity to R43C98 R43C98 FO Wear, no PLP 04H-0.73 27%TW, no prior history. Preventatively plugged due to atypical growth F. Number and percentage of tubes plugged to date, and the effective plugging percentage in each steam generator The number and percentage of SG tubes plugged to-date, and the effective plugging percentage in each SG are summarized in Table 6.

Table 6 - Tubes plugged to-date and effective plugging percentage SG-A SG-B SG-C SG-D Total Tubes Plugged 42 27 61 65 195 Percent Plugged 0.75%

0.48%

1.08%

1.16%

0.87%

G. Results of Condition Monitoring, including the results of tube pulls and in-situ testing All indications found in OR19 satisfy the condition monitoring (CM) requirements of NEI 97-06 for structural and leakage integrity. No indications were found to exceed structural limits. The tubes identified for plugging were screened against the in-situ test selection criteria contained in the EPRI SGMP Steam Generator In Situ Pressure Test Guidelines, Rev 5, and provided for Seabrook conditions. None of the tubes identified for plugging met the requirements for in-situ testing. The OR19 Page 7 of 22

inspection results validate the projections and conclusions of the Operational Assessment of the previous inspection at OR17.

1. A single axial indication (SAI) of PWSCC was detected in tube, R33C93, at the TTS expansion transition in SG-C during the HL tubesheet inspection program using the +Point' probe. For this indication, the maximum +Point' probe voltage was 0.58 volt for a crack length of 0.21 inch, which is slightly above the first ISPT proof screen per the Seabrook degradation assessment.

However, the crack length (0.21 inch) was less than the structural length for a 100%TW crack (0.40 inch). The flaw maximum +Point' probe voltage is also significantly less than the initial VCRIT and VTHR-L voltage screens for leakage integrity. The indication was shown to have 95% probability at 50% confidence burst pressure greater than the limiting differential pressure of 3900 psid. Thus, it passed the screening criteria for burst and leak testing. Therefore, condition monitoring requirements are met, and an ISPT was not necessary. No pitting was observed during the OR19 inspection.

2. The maximum observed AVB wear indication (39% TW) meets the CM requirements with 95%

probability at 50% confidence, (when all uncertainties are considered at their 95% probability values).

3. The maximum observed volumetric indications (indicative of mechanical wear) were 39% TW.

These indications have shown no growth since the last inspection, and are less than the structural limit when all uncertainties are considered. All volumetric indications met the CM requirements with 95% probability at 50% confidence.

4. The maximum wear observed during the OR19 inspection due to foreign objects was 35% TW; the structural limit for the local wear is 56% TWD. There was no wear associated with any of the PLP indications reported during the previous inspection. The 2 SVI indications (Table 4) which had associated PLPs were both plugged and stabilized since the growth rate cannot be adequately quantified. The previously-reported wear at the FDB was reported again during OR19. These signals are not changing, and the magnitude of the wear does not challenge the requirements for condition monitoring. Therefore, wear due to foreign objects meets the performance requirements for Condition Monitoring.
5. The predicted accident induced leakage for H* meets the Condition Monitoring leakage requirements. In SG-B, in which operating leakage has been observed, the predicted leakage from the tubesheet expansion region is 2.49 gpd (.0017 gpm). No leakage was detected from the SCC indication in SG-C. SGs A and D are free from indications with the potential to leak and have no reportable normal operating leakage. Therefore, the Seabrook SGs meet the Condition Monitoring requirements with regard to leakage.
6. Channelhead Components Visual Inspection:

Tube Plug Inspection: During the inspection of tube plugs in OR19, all installed plugs were confirmed to be in their correct location. In addition, all plugs were found to be dry; no dripping plugs were identified. No degradation or visible signs of leakage were noted on the plugs during the visual inspection.

Other Channelhead Inspections: Visual inspection of various channelhead components were performed to identify degradation per guidance in Westinghouse NSAL 12-1 Rev 1, Steam Generator Channel Head Degradation and LR-ISG-2016-01, Changes to Aging Management Guidance for Various Steam Generator Components. Areas inspected include the divider plate-to-channelhead weld, the weld at the top of the channelhead bowl drain tube, the channelhead-to-tubesheet girth weld seam region, the divider plate, and all cladded surfaces of the channelhead bowl and tubesheet. No degradation was found; the observed condition during the OR19 inspection is consistent with the manufacturing process.

7. Secondary-side Inspections and Maintenance:

Sludge Lancing and FOSAR: A total of approximately 130.5 lbs. of sludge was removed from the 4 SGs based on sludge lancing in OR19. The TTS region was essentially clean with some hardened collars noted at the center of the bundle where flow rates are low during operation.

Page 8 of 22

Nine (9) foreign objects were identified during FOSAR activities in OR19. Two (2) of the objects (sludge rocks) were removed. The remaining objects comprised mainly of sludge rocks, and 2 legacy objects: a previously-reported dumbbell-shaped object, and a hollow metal fitting identified in OR19 in SG-D. The newly-identified metal object appears to have been in place since the SG was manufactured since it fills the gap between 4 neighboring tubes, and cannot be retrieved. No wear was identified on any of the 4 bounding tubes during ECT, and no tube damage was observed in any SG during FOSAR activities.

Upper Internals Inspection: Visual inspections performed in SG-D (for erosion/corrosion, mechanical damage, foreign material and unusual conditions) included the dryers, swirl vanes, feedring and J-nozzles. A band of discoloration was observed on the wall of the steam drum, just above the feedring. This appears to have been caused by a thin layer of magnetite that had spalled from the wall in this region; however, the base material appears to be intact. A minimal amount of scouring was observed inside some of the J-tubes at the interface with the feedring.

UT thickness readings were taken at select locations on the feedring; no abnormal conditions were noted. No erosion/corrosion or degradation was noted during visual inspections of the upper steam drum components.

H. Primary-to-secondary leakage rate observed in each SG during the previous cycle Seabrook has tracked detectable normal operating leakage in SG-B that has varied between 0.2 gpd and 1.0 gpd during the fuel cycle preceding the OR19 inspection. This low level of leakage has been detected for several cycles, fluctuating between 0 and 1.2 gpd. No normal operating leakage has been detected in SG-A, SG-C, or SG-D.

I. Calculated accident induced leakage rate For application of H*, Seabrook committed that the component of operational leakage from the prior cycle from below the H* distance will be multiplied by a factor of 2.49 and added to the total accident leakage from any other source and compared to the allowable accident induced leakage limit.

The assumed value for accident induced leakage in the Seabrook UFSAR is 500 gpd (=0.35 gpm) for the faulted steam generator and 940 gpd through the remaining three SGs, for a total leakage of 1440 gpd (=1.0 gpm). As stated in Section H, SG-B experienced leakage in the range of 0.2 gpd to 1.0 gpd in the fuel cycle preceding the OR19 inspection. Since there is no observed operating leakage from the remaining SGs (SG-A, SG-C and SG-D), the predicted accident induced leakage for each of these is zero.

Because there is no other degradation mechanism in SG-B that has been shown to be the source of the observed leakage, the entire observed operating leakage is assumed to come from the tubesheet expansion region. Conservatively assuming that the operating leakage in SG-B is at the upper end of the observed range (i.e. 1.0 gpd), the predicted accident induced leakage (QDBA) in SG-B is:

QDBA = 2.49 x 1.0 gpd = 2.49 gpd (=0.0017 gpm)

Therefore, since the predicted accident induced leakage from SG-B (2.49 gpd) is less than the UFSAR limit (500 gpd) for leakage through any one SG, and less than the total leakage limit for all SGs (1440 gpd), the accident induced leakage performance criteria are met.

J. Results of monitoring for tube axial displacement (slippage)

A condition for licensing H* was to monitor for tube slippage within the tubesheet region. Monitoring for slippage was accomplished in accordance with the slippage monitoring guidance provided in Westinghouse LTR-SGMP-09-140 H*: Guidance for Monitoring Tube Slippage Using the Bobbin Probe Data, September 22, 2009 (proprietary). No tube slippage was detected during the OR19 inspection.

Page 9 of 22

APPPENDIX A - Additional Information References to prior SG Tube Inspection Reports (3rd inspection period)

Inspection #

EOC Outage NRC ADAMS Accession No.

1 EOC-15 OR15 ML13008A160 2

EOC-16 OR16 ML14297A090 3

EOC-17 OR17 ML16120A203 4

EOC-18 OR18 ML17291B270 Abbreviations and Acronyms:

ARC Alternate Repair Criteria AVB Anti Vibration Bar BLG Bulge CL Cold Leg CM Condition Monitoring DA Degradation Assessment DBA Design Bases Accident DNG Ding DNT Dent ECT Eddy Current Testing EFPM Effective Full Power Months EFPY Effective Full Power Years EPRI Electric Power Research Institute ETSS Exam Technique Spec Sheet FDB Flow Distribution Baffle FO Foreign Object FOSAR Foreign Object Search and Retrieval GPD (gpd)

Gallons per Day GPM (gpm)

Gallons per Minute HL Hot Leg ID Inside Diameter ISPT In-Situ Pressure Test MNT Maintenance Related NDD No Degradation Detectable NEI Nuclear Energy Institute NSAL Nuclear Safety Advisory Letter OD Outside Diameter ODSCC OD Stress Corrosion Cracking OXP Over-expansion Per Percent Through-Wall PLP Possible Loose Part POD Probability of Detection PWSCC Primary Water SCC SAI Single Axial Indication SCC Stress Corrosion Cracking SED Structural Equivalent Depth SEL Structural Equivalent Length SG Steam Generator SGMP SG Management Program SLB Steam Line Break SVI Single Volumetric Indication TS Tubesheet TSC Tube Sheet Cold TSH Tube Sheet Hot TSP Tube Support Plate TTS Top of Tube Sheet TW Through Wall TWD Through Wall Depth UFSAR Updated Final Safety Analysis Rpt VCRIT Critical voltage for leakage VTHR-L Threshold voltage for leak testing VOL Volumetric Page 10 of 22

APPENDIX B - OR19 List of Imperfections (non-SCC)

SG Row Col Per Locn A

1 11 21 01C A

1 36 23 TSC A

1 87 31 TSC A

4 87 9

06C A

5 108 14 06C A

17 67 14 AV1 A

17 71 14 AV1 A

18 58 15 AV1 A

18 82 7

06C A

19 40 29 AV1 A

19 54 21 AV1 A

19 58 16 AV1 A

19 61 16 AV1 A

19 61 13 AV6 A

20 48 14 AV1 A

21 26 18 03H A

23 36 12 AV1 A

23 37 14 AV6 A

23 38 14 AV2 A

23 42 19 AV6 A

23 45 19 AV5 A

23 45 16 AV6 A

23 52 15 AV2 A

23 52 15 AV5 A

23 59 23 AV2 A

23 59 20 AV5 A

23 61 11 AV2 A

24 7

17 AV1 A

24 7

14 AV6 A

24 59 21 AV2 A

24 59 20 AV5 A

24 59 15 AV6 A

24 71 16 AV2 A

24 71 16 AV5 A

25 7

18 AV1 A

25 56 16 AV2 A

25 59 16 AV2 A

25 68 14 AV1 A

25 83 14 AV2 A

26 107 29 AV6 A

27 12 13 AV6 A

27 63 17 AV2 A

27 112 13 AV1 SG Row Col Per Locn A

27 112 14 AV5 A

28 44 16 AV2 A

28 44 16 AV5 A

28 59 28 AV2 A

28 59 22 AV5 A

29 11 21 AV2 A

29 71 12 AV2 A

29 82 23 AV2 A

29 82 18 AV6 A

29 84 19 AV5 A

29 84 16 AV6 A

29 94 30 AV2 A

30 11 25 AV5 A

30 12 12 AV1 A

30 12 18 AV5 A

30 12 16 AV6 A

30 31 16 AV5 A

30 58 18 AV5 A

30 58 18 AV6 A

30 64 17 AV2 A

30 64 15 AV5 A

30 68 15 AV1 A

30 68 15 AV2 A

30 89 12 AV2 A

30 95 12 AV6 A

30 102 19 AV5 A

30 109 15 AV1 A

30 109 15 AV5 A

30 109 16 AV6 A

30 111 15 AV1 A

30 111 19 AV5 A

31 11 19 AV5 A

31 12 35 AV5 A

31 12 21 AV6 A

31 13 15 AV6 A

31 64 16 AV2 A

31 68 15 AV2 A

31 69 16 AV5 A

31 105 13 AV1 A

32 89 14 AV3 A

33 14 16 AV1 A

33 14 12 AV2 A

33 15 12 AV4 SG Row Col Per Locn A

33 15 22 AV5 A

33 15 18 AV6 A

33 71 14 AV1 A

33 71 13 AV2 A

33 92 19 AV1 A

33 106 16 AV1 A

34 17 13 AV3 A

34 17 12 AV6 A

34 51 24 AV2 A

34 51 23 AV3 A

34 59 15 AV2 A

34 59 13 AV3 A

34 87 17 AV3 A

34 87 17 AV4 A

34 94 19 AV1 A

34 95 16 AV3 A

34 97 19 AV2 A

34 103 16 AV1 A

35 14 17 AV2 A

35 14 17 AV4 A

35 14 20 AV5 A

35 14 13 AV6 A

35 31 17 AV3 A

35 31 19 AV5 A

35 55 16 AV2 A

35 55 13 AV4 A

35 58 24 AV1 A

35 58 34 AV2 A

35 58 39 AV3 A

35 58 39 AV4 A

35 58 32 AV5 A

35 58 20 AV6 A

35 61 14 AV1 A

35 61 17 AV2 A

35 61 19 AV3 A

35 61 35 AV4 A

35 61 30 AV5 A

35 61 14 AV6 A

35 70 17 AV2 A

35 73 24 AV2 A

35 73 20 AV3 A

35 80 32 03H A

35 88 25 03H Page 11 of 22

APPENDIX B - OR19 List of Imperfections (non-SCC)

SG Row Col Per Locn A

36 110 12 AV2 A

37 87 13 AV2 A

37 99 13 AV1 A

37 99 16 AV3 A

37 99 17 AV4 A

37 102 26 AV1 A

37 102 19 AV4 A

37 102 20 AV5 A

37 105 17 AV1 A

37 105 22 AV4 A

37 105 15 AV5 A

39 63 21 AV2 A

39 63 20 AV3 A

39 79 13 AV2 A

39 79 18 AV3 A

39 79 25 AV4 A

39 79 24 AV5 A

39 80 21 AV3 A

40 71 23 AV2 A

40 86 20 AV1 A

40 86 28 AV2 A

40 86 20 AV4 A

40 86 21 AV5 A

40 94 25 AV2 A

40 94 20 AV4 A

40 96 17 AV1 A

40 102 20 AV3 A

40 102 24 AV4 A

40 103 16 AV3 A

40 103 25 AV4 A

40 103 25 AV5 A

41 35 15 AV3 A

41 50 15 AV1 A

41 50 20 AV2 A

41 50 22 AV3 A

41 50 25 AV4 A

41 50 37 AV5 A

41 53 18 AV1 A

41 53 17 AV2 A

41 53 18 AV3 A

41 53 24 AV4 A

41 53 25 AV5 A

41 54 28 AV2 SG Row Col Per Locn A

41 54 26 AV3 A

41 54 17 AV5 A

41 58 15 AV1 A

41 58 21 AV2 A

41 58 21 AV3 A

41 58 20 AV4 A

41 58 17 AV5 A

41 59 26 AV2 A

41 59 17 AV3 A

41 59 13 AV5 A

41 68 20 AV2 A

41 68 36 AV3 A

41 68 27 AV4 A

41 68 25 AV5 A

41 68 18 AV6 A

41 78 16 AV2 A

41 78 20 AV3 A

41 78 12 AV5 A

41 84 16 AV2 A

41 84 15 AV4 A

41 91 22 AV1 A

41 91 21 AV2 A

41 102 19 AV1 A

41 102 22 AV4 A

41 102 24 AV5 A

41 103 21 AV1 A

41 103 12 AV3 A

41 103 22 AV4 A

41 103 24 AV5 A

41 103 15 AV6 A

42 22 14 AV4 A

42 58 29 AV3 A

42 58 20 AV4 A

42 58 21 AV5 A

42 72 18 AV1 A

42 72 21 AV2 A

42 72 33 AV3 A

42 72 25 AV4 A

42 72 30 AV5 A

42 72 18 AV6 A

42 80 11 AV1 A

42 80 31 AV2 A

42 80 33 AV3 SG Row Col Per Locn A

42 80 23 AV4 A

42 80 20 AV5 A

42 80 27 AV6 A

42 81 19 AV4 A

42 83 14 AV2 A

42 103 20 AV1 A

43 20 13 AV6 A

43 55 19 AV2 A

43 98 23 AV5 A

44 66 17 AV1 A

44 94 18 AV2 A

44 94 22 AV3 A

44 94 20 AV4 A

44 98 19 AV1 A

44 98 23 AV2 A

44 98 29 AV3 A

44 98 23 AV4 A

44 98 21 AV5 A

44 100 18 AV1 A

44 100 21 AV3 A

44 100 21 AV5 A

44 101 22 AV1 A

44 102 18 AV2 A

45 23 11 01H A

45 67 18 AV2 A

45 68 18 AV2 A

45 74 20 AV1 A

45 74 22 AV2 A

45 74 29 AV3 A

45 74 33 AV4 A

45 76 17 AV1 A

45 80 14 AV3 A

45 80 15 AV4 A

45 98 18 AV4 A

46 24 19 01H A

46 65 20 AV4 A

46 65 26 AV5 A

46 71 11 AV3 A

46 71 19 AV4 A

46 71 18 AV5 A

46 77 19 AV2 A

46 77 19 AV3 A

46 77 25 AV4 Page 12 of 22

APPENDIX B - OR19 List of Imperfections (non-SCC)

SG Row Col Per Locn A

46 94 20 AV6 A

46 95 14 AV4 A

46 95 20 AV5 A

46 95 19 AV6 A

46 97 16 AV6 A

46 98 26 AV4 A

46 98 23 AV5 A

46 98 20 AV6 A

47 85 23 AV5 A

47 89 19 AV3 A

47 89 17 AV6 A

47 95 13 AV1 A

47 95 19 AV2 A

47 95 22 AV3 A

47 95 22 AV4 A

47 95 14 AV5 A

47 95 16 AV6 A

47 98 20 AV5 A

48 31 17 AV3 A

48 31 17 AV4 A

48 31 14 AV5 A

48 31 16 AV6 A

48 60 24 AV6 A

48 63 15 AV1 A

48 63 25 AV2 A

48 63 26 AV3 A

48 63 25 AV4 A

48 63 22 AV5 A

48 64 25 AV2 A

48 83 16 AV3 A

48 83 21 AV4 A

48 91 15 AV3 A

48 91 14 AV4 A

48 91 12 AV5 A

48 92 18 AV6 A

48 94 21 AV4 A

48 94 18 AV5 A

48 94 23 AV6 A

48 95 12 AV4 A

48 95 17 AV5 A

48 95 22 AV6 A

48 96 24 AV6 A

49 28 12 AV2 SG Row Col Per Locn A

49 29 22 TSH A

49 48 12 AV1 A

49 54 15 AV3 A

49 57 12 AV2 A

49 57 13 AV4 A

49 57 14 AV5 A

49 57 12 AV6 A

49 60 14 AV3 A

49 64 26 AV1 A

49 65 16 AV1 A

49 65 23 AV2 A

49 65 38 AV3 A

49 65 26 AV4 A

49 65 21 AV5 A

49 76 19 AV2 A

49 88 18 AV2 A

49 88 29 AV3 A

49 88 28 AV4 A

49 88 33 AV5 A

49 88 21 AV6 A

49 90 21 AV5 A

49 90 19 AV6 A

49 91 13 AV5 A

50 29 14 TSH A

50 38 18 AV4 A

50 38 19 AV5 A

50 60 15 AV2 A

50 60 14 AV3 A

50 66 18 AV2 A

50 71 14 AV2 A

50 80 17 AV3 A

50 80 16 AV4 A

50 80 15 AV5 A

50 85 12 AV2 A

50 85 27 AV3 A

50 85 24 AV4 A

50 85 19 AV5 A

50 85 18 AV6 A

50 88 27 AV6 A

50 95 24 AV3 A

50 95 27 AV4 A

50 95 36 AV5 A

50 95 31 AV6 SG Row Col Per Locn A

51 52 16 AV4 A

51 53 14 AV4 A

51 71 15 AV4 A

51 75 19 AV5 A

51 86 21 AV1 A

51 86 29 AV2 A

51 86 24 AV3 A

51 86 21 AV4 A

51 86 17 AV6 A

51 90 23 AV2 A

51 90 23 AV3 A

51 90 28 AV4 A

51 90 27 AV5 A

51 90 22 AV6 A

52 53 14 AV2 A

52 57 13 AV3 A

52 73 19 AV3 A

52 73 20 AV5 A

52 88 22 AV3 A

52 88 35 AV4 A

52 88 33 AV5 A

52 88 27 AV6 A

52 89 13 AV3 A

52 89 26 AV4 A

52 89 31 AV5 A

52 89 29 AV6 A

52 90 23 AV6 A

53 33 10 TSH A

53 45 23 AV2 A

53 45 12 AV3 A

53 69 17 AV5 A

53 89 16 AV1 A

53 90 19 AV4 A

54 86 16 AV2 A

55 41 16 AV5 A

55 41 16 AV6 A

56 57 12 AV2 A

56 81 13 AV4 A

57 48 17 AV1 A

57 48 17 AV2 A

57 52 12 AV1 A

57 61 13 AV2 A

58 50 15 AV6 Page 13 of 22

APPENDIX B - OR19 List of Imperfections (non-SCC)

SG Row Col Per Locn A

58 76 17 AV2 A

58 76 19 AV3 SG Row Col Per Locn B

1 11 35 TSC B

1 87 39 TSC B

1 87 39 TSH B

1 112 17 TSH B

1 119 13 01H B

2 98 35 06C B

5 86 14 04H B

12 65 16 AV1 B

15 68 18 AV1 B

17 64 19 AV1 B

17 69 13 AV1 B

17 77 12 AV1 B

18 66 17 AV1 B

18 74 17 AV1 B

19 66 18 AV1 B

20 60 26 AV1 B

20 60 16 AV6 B

20 60 13 AV6 B

21 68 16 AV1 B

21 77 14 AV1 B

21 115 14 AV6 B

22 36 13 AV1 B

22 36 13 AV2 B

22 36 14 AV6 B

22 69 14 AV1 B

22 89 18 AV2 B

22 89 17 AV6 B

22 97 28 05H B

22 116 13 AV2 B

23 47 22 AV1 B

23 47 17 AV2 B

23 49 18 AV1 B

23 49 14 AV2 SG Row Col Per Locn B

23 56 18 AV1 B

23 56 16 AV2 B

24 43 16 AV2 B

24 43 16 AV5 B

24 45 16 AV2 B

25 51 19 AV1 B

25 51 23 AV2 B

25 51 21 AV5 B

25 82 14 AV2 B

25 112 16 AV1 B

27 42 19 AV2 B

27 57 14 AV2 B

27 63 16 AV5 B

27 81 13 AV5 B

27 107 20 AV5 B

27 112 15 AV1 B

28 42 17 AV2 B

28 42 16 AV5 B

28 65 13 AV2 B

28 65 15 AV6 B

28 78 18 AV2 B

28 115 16 AV2 B

28 115 15 AV5 B

29 30 17 AV2 B

29 32 16 AV6 B

29 38 16 AV2 B

29 38 17 AV5 B

29 38 14 AV6 B

29 51 18 AV2 B

29 79 30 AV1 B

29 79 24 AV2 B

29 79 21 AV5 B

29 79 17 AV6 B

29 89 14 AV1 B

29 89 17 AV2 B

29 101 19 AV2 B

29 113 18 AV1 B

29 113 23 AV5 B

29 113 13 AV6 B

30 43 18 AV2 B

30 43 22 AV5 B

30 43 23 AV6 B

30 49 16 AV2 SG Row Col Per Locn B

30 58 18 AV5 B

30 61 23 AV2 B

30 61 35 AV5 B

30 62 18 AV2 B

30 66 15 AV1 B

30 66 17 AV2 B

30 66 21 AV5 B

30 66 15 AV6 B

30 71 15 AV5 B

30 73 15 AV2 B

30 73 15 AV5 B

30 75 28 AV2 B

30 75 21 AV5 B

30 79 16 AV2 B

30 79 13 AV5 B

30 80 14 AV1 B

30 80 21 AV2 B

30 80 19 AV5 B

30 81 25 AV2 B

30 81 29 AV5 B

30 87 19 AV2 B

30 87 29 AV5 B

30 87 19 AV6 B

30 106 17 AV1 B

30 106 19 AV6 B

30 109 18 AV5 B

30 111 17 AV2 B

30 111 23 AV5 B

30 112 15 AV1 B

30 112 20 AV2 B

30 112 17 AV5 B

31 66 16 AV6 B

31 111 25 AV5 B

31 112 16 AV1 B

31 112 19 AV2 B

32 81 13 AV2 B

32 82 25 AV2 B

32 82 16 AV5 B

32 82 16 AV6 B

32 83 14 AV2 B

32 83 15 AV3 B

32 83 17 AV5 B

32 86 19 AV2 Page 14 of 22

APPENDIX B - OR19 List of Imperfections (non-SCC)

SG Row Col Per Locn B

32 86 18 AV3 B

32 86 17 AV4 B

32 88 14 AV1 B

32 88 17 AV2 B

32 88 17 AV3 B

32 88 14 AV5 B

32 103 18 AV2 B

32 109 18 AV5 B

32 109 15 AV6 B

33 95 17 AV2 B

33 104 16 AV2 B

33 104 14 AV4 B

33 107 13 AV3 B

33 107 16 AV5 B

33 109 15 AV4 B

33 109 30 AV5 B

34 14 17 AV5 B

34 14 20 AV6 B

34 70 23 AV2 B

34 70 16 AV3 B

34 70 15 AV4 B

34 72 16 AV2 B

34 82 16 AV2 B

34 85 13 AV2 B

34 85 11 AV6 B

34 94 16 AV2 B

34 94 15 AV5 B

34 94 15 AV6 B

34 98 17 AV2 B

34 98 17 AV3 B

34 100 15 AV5 B

34 100 15 AV6 B

34 101 15 AV2 B

34 101 12 AV6 B

34 103 16 AV5 B

34 103 19 AV6 B

34 105 16 AV6 B

35 44 18 AV1 B

35 44 15 AV2 B

35 55 18 AV4 B

35 58 15 AV2 B

35 58 21 AV3 B

35 58 21 AV4 SG Row Col Per Locn B

35 58 19 AV5 B

35 59 14 AV1 B

35 59 17 AV2 B

35 59 12 AV3 B

35 59 15 AV4 B

35 67 19 AV2 B

35 67 18 AV3 B

35 67 14 AV4 B

35 68 8

AV1 B

35 68 16 AV2 B

35 68 20 AV3 B

35 68 21 AV4 B

35 68 21 AV5 B

35 71 10 AV3 B

35 98 17 AV3 B

35 98 14 AV4 B

35 104 15 AV3 B

35 104 15 AV6 B

36 59 17 AV2 B

36 59 13 AV6 B

36 64 13 AV3 B

36 64 16 AV4 B

36 65 31 AV2 B

36 65 20 AV3 B

36 65 14 AV4 B

36 65 22 AV5 B

37 54 10 AV2 B

37 54 17 AV4 B

37 58 14 AV3 B

37 69 23 AV2 B

37 87 15 AV2 B

37 87 18 AV3 B

38 41 16 AV6 B

39 48 9

AV2 B

39 48 19 AV3 B

39 48 17 AV4 B

39 48 17 AV5 B

39 49 14 AV1 B

39 49 27 AV2 B

39 49 28 AV3 B

39 49 21 AV4 B

39 54 12 AV1 B

39 54 17 AV2 SG Row Col Per Locn B

39 54 22 AV3 B

39 54 21 AV4 B

39 54 16 AV5 B

39 56 16 AV1 B

39 56 18 AV2 B

39 57 11 AV1 B

39 57 16 AV2 B

39 57 14 AV3 B

39 57 15 AV4 B

39 57 13 AV5 B

39 59 18 AV1 B

39 60 10 AV1 B

39 60 11 AV2 B

39 60 21 AV3 B

39 60 12 AV4 B

40 48 32 AV2 B

40 48 15 AV2 B

40 48 35 AV3 B

40 48 28 AV4 B

40 48 27 AV5 B

40 48 15 AV6 B

40 74 11 AV2 B

41 61 20 AV2 B

41 61 22 AV4 B

41 61 15 AV5 B

41 75 23 AV2 B

41 75 22 AV3 B

41 75 19 AV4 B

41 75 16 AV5 B

42 64 11 AV2 B

42 64 11 AV5 B

42 81 18 AV2 B

42 103 16 AV4 B

43 20 15 AV2 B

43 69 17 AV2 B

43 69 15 AV3 B

43 69 26 AV4 B

43 69 27 AV5 B

43 75 24 AV2 B

43 75 19 AV3 B

43 75 29 AV4 B

43 75 28 AV5 B

43 96 19 TSH Page 15 of 22

APPENDIX B - OR19 List of Imperfections (non-SCC)

SG Row Col Per Locn B

44 62 10 AV2 B

44 62 10 AV4 B

45 27 15 AV6 B

45 33 22 AV2 B

45 41 23 AV2 B

45 41 21 AV3 B

45 41 18 AV4 B

45 47 15 AV5 B

45 74 11 AV2 B

45 86 22 AV1 B

46 66 11 AV3 B

47 71 15 AV1 B

47 71 20 AV2 B

47 71 28 AV3 B

47 71 15 AV4 B

47 74 13 AV2 B

48 25 12 AV5 B

48 71 13 AV4 B

49 33 19 AV2 B

49 78 21 AV2 B

49 78 18 AV4 B

50 93 14 AV2 B

50 93 16 AV4 B

50 95 17 AV6 B

51 70 16 AV5 B

51 70 19 AV6 B

53 34 21 AV6 B

53 44 11 AV6 B

53 90 14 AV4 B

53 90 22 AV5 B

53 90 16 AV6 B

54 36 17 AV5 B

54 66 14 AV3 B

54 86 16 AV2 B

54 86 13 AV4 B

54 86 18 AV5 B

54 87 19 01C B

54 87 13 AV3 B

54 87 21 AV5 B

55 55 18 AV3 B

55 63 16 AV3 B

55 69 11 AV2 B

55 69 18 AV3 SG Row Col Per Locn B

56 69 15 AV2 B

56 71 13 AV2 B

56 82 22 AV5 B

57 50 15 AV6 B

57 55 16 AV6 B

57 69 14 AV2 B

58 57 20 AV2 SG Row Col Per Locn C

1 87 11 TSC C

1 87 38 TSH C

1 112 15 TSC C

1 112 26 TSH C

3 90 23 07C C

3 113 33 05C C

5 57 26 06C C

9 67 14 AV1 C

9 74 14 AV1 C

10 63 24 AV1 C

10 63 19 AV6 C

10 64 19 AV1 C

11 67 19 AV1 C

11 72 16 AV1 C

14 62 17 AV1 C

15 35 12 AV1 C

15 64 19 AV1 C

15 67 20 AV1 C

16 37 16 AV6 C

19 59 16 AV1 C

19 62 19 AV1 C

22 34 18 AV2 C

24 7

18 AV1 C

24 7

19 AV6 C

24 98 15 AV1 C

25 10 12 AV1 C

25 56 19 AV2 C

26 8

17 AV1 C

28 66 19 AV2 C

28 104 25 05C SG Row Col Per Locn C

30 11 16 AV1 C

30 11 16 AV5 C

30 11 15 AV6 C

30 113 22 AV2 C

30 113 15 AV5 C

30 113 16 AV6 C

30 114 17 AV2 C

30 114 14 AV5 C

30 114 10 AV6 C

31 111 19 AV5 C

32 24 27 04H C

32 35 9

07C C

32 110 15 AV3 C

33 42 21 AV4 C

33 42 21 AV6 C

33 106 13 AV2 C

33 106 18 AV3 C

33 106 22 AV4 C

33 111 17 AV2 C

33 111 16 AV5 C

34 28 17 AV4 C

34 28 17 AV5 C

35 13 13 AV1 C

35 13 28 AV2 C

35 13 18 AV3 C

35 13 28 AV4 C

35 13 35 AV5 C

35 13 19 AV6 C

36 43 17 AV2 C

37 17 18 AV5 C

37 23 16 AV1 C

37 23 11 AV4 C

37 23 19 AV5 C

37 40 18 AV2 C

37 40 18 AV3 C

37 40 15 AV4 C

37 40 15 AV5 C

37 40 16 AV6 C

37 47 20 AV4 C

37 47 12 AV5 C

37 55 19 AV2 C

37 56 19 AV2 C

37 78 14 AV5 Page 16 of 22

APPENDIX B - OR19 List of Imperfections (non-SCC)

SG Row Col Per Locn C

37 83 16 AV2 C

37 85 22 AV2 C

37 85 18 AV3 C

37 85 21 AV4 C

37 85 19 AV5 C

37 85 18 AV6 C

38 79 20 AV1 C

38 79 18 AV2 C

38 101 16 AV6 C

38 102 18 AV4 C

38 102 21 AV5 C

39 19 17 TSC C

39 42 20 AV2 C

39 42 15 AV3 C

39 42 20 AV4 C

39 45 22 AV2 C

39 45 30 AV3 C

39 45 26 AV4 C

39 45 37 AV5 C

39 45 17 AV6 C

39 69 23 AV2 C

39 69 21 AV3 C

39 69 30 AV4 C

39 69 29 AV5 C

40 36 15 AV1 C

40 36 19 AV2 C

41 22 19 AV2 C

41 22 19 AV3 C

41 22 16 AV4 C

41 22 20 AV5 C

41 22 17 AV6 C

41 23 21 AV1 C

41 23 20 AV5 C

41 23 16 AV6 C

41 30 14 AV4 C

41 30 20 AV5 C

41 30 20 AV6 C

41 39 27 AV2 C

41 39 22 AV4 C

41 39 23 AV5 C

41 39 24 AV6 C

41 41 21 AV1 C

41 41 35 AV2 SG Row Col Per Locn C

41 41 23 AV3 C

41 41 22 AV4 C

41 43 19 AV2 C

41 43 19 AV3 C

41 43 29 AV4 C

41 43 17 AV5 C

41 80 21 AV2 C

41 80 34 AV3 C

41 80 22 AV4 C

41 80 19 AV5 C

41 93 10 AV1 C

41 93 13 AV2 C

41 93 13 AV3 C

41 93 17 AV4 C

41 93 22 AV5 C

41 100 19 AV3 C

41 100 20 AV4 C

41 100 28 AV5 C

41 100 14 AV6 C

42 23 21 AV4 C

42 23 25 AV5 C

42 24 17 AV6 C

42 25 13 AV2 C

42 25 14 AV3 C

42 25 17 AV4 C

42 25 17 AV5 C

42 25 13 AV6 C

42 31 14 AV1 C

42 31 27 AV2 C

42 31 13 AV3 C

42 56 16 AV2 C

42 71 21 AV2 C

42 71 17 AV5 C

42 92 17 AV2 C

42 92 23 AV3 C

42 92 16 AV4 C

42 92 20 AV5 C

42 98 12 04H C

42 102 15 AV1 C

42 102 18 AV2 C

42 102 36 AV3 C

42 102 35 AV4 C

42 102 17 AV5 SG Row Col Per Locn C

42 102 23 AV6 C

43 23 19 AV1 C

43 23 29 AV3 C

43 23 17 AV4 C

43 23 20 AV5 C

43 26 24 TSH C

43 98 27 04H C

43 100 17 AV2 C

43 100 17 AV3 C

43 100 36 AV4 C

43 100 26 AV5 C

43 102 22 AV2 C

43 102 25 AV3 C

43 102 34 AV4 C

43 102 30 AV5 C

43 102 19 AV6 C

44 22 16 AV2 C

44 26 12 TSH C

44 75 21 AV1 C

44 75 22 AV2 C

44 100 17 AV2 C

44 100 22 AV3 C

44 100 36 AV4 C

44 100 36 AV5 C

44 100 19 AV6 C

46 36 22 AV2 C

46 36 26 AV3 C

46 36 33 AV4 C

46 36 25 AV5 C

46 79 17 AV2 C

46 79 21 AV3 C

46 79 22 AV4 C

46 79 17 AV5 C

46 79 21 AV6 C

46 97 17 AV3 C

46 97 23 AV4 C

46 97 15 AV5 C

47 30 22 AV5 C

47 35 18 AV1 C

47 35 24 AV2 C

47 35 32 AV3 C

47 35 32 AV4 C

47 35 20 AV5 Page 17 of 22

APPENDIX B - OR19 List of Imperfections (non-SCC)

SG Row Col Per Locn C

47 40 21 AV2 C

47 40 16 AV3 C

47 40 23 AV4 C

47 40 22 AV5 C

47 40 20 AV6 C

47 57 13 AV2 C

47 62 14 AV4 C

47 76 19 AV1 C

47 76 21 AV2 C

47 83 18 AV5 C

47 86 17 AV4 C

47 86 16 AV5 C

47 93 10 AV1 C

47 93 22 AV3 C

47 93 25 AV4 C

47 93 35 AV5 C

47 94 14 AV2 C

47 94 16 AV3 C

47 94 24 AV4 C

47 94 20 AV5 C

47 94 16 AV6 C

47 96 13 AV3 C

47 96 16 AV5 C

47 96 14 AV6 C

47 98 17 AV3 C

47 98 18 AV4 C

47 99 17 AV4 C

47 99 30 AV5 C

47 99 27 AV6 C

48 30 16 AV4 C

48 30 20 AV5 C

48 30 17 AV6 C

48 33 21 AV5 C

48 35 17 AV4 C

48 35 20 AV5 C

48 47 17 AV1 C

48 47 19 AV2 C

48 47 14 AV3 C

48 97 16 AV2 C

48 97 19 AV3 C

48 97 18 AV4 C

49 95 27 AV5 C

50 28 19 AV1 SG Row Col Per Locn C

51 49 18 AV1 C

51 49 26 AV2 C

51 49 20 AV3 C

51 67 14 AV4 C

51 67 17 AV6 C

53 33 15 AV3 C

53 35 18 AV2 C

53 35 13 AV4 C

53 63 17 AV2 C

53 67 15 AV1 C

53 67 32 AV2 C

53 67 34 AV3 C

53 67 23 AV4 C

53 70 18 AV1 C

53 70 25 AV2 C

53 70 17 AV3 C

54 35 14 AV4 C

54 37 16 AV1 C

54 39 18 AV1 C

54 68 24 AV2 C

54 87 15 AV3 C

54 87 18 AV4 C

54 87 23 AV5 C

55 39 18 AV1 C

56 65 15 AV3 C

58 51 15 AV6 C

59 67 16 AV6 Page 18 of 22

APPENDIX B - OR19 List of Imperfections (non-SCC)

SG Row Col Per Locn D

1 87 33 TSH D

6 108 10 03H D

12 2

13 AV1 D

13 4

26 01C D

16 64 20 AV1 D

16 64 19 AV6 D

17 72 18 AV1 D

17 75 15 AV6 D

21 52 24 04H D

22 86 14 AV2 D

22 93 13 AV2 D

22 93 15 AV6 D

24 6

22 AV1 D

24 6

21 AV6 D

24 89 13 AV5 D

24 89 13 AV6 D

24 91 14 AV2 D

24 116 11 AV5 D

25 82 18 AV2 D

25 82 13 AV5 D

26 8

17 AV1 D

26 8

22 AV6 D

26 40 11 AV1 D

26 40 18 AV5 D

26 41 15 AV2 D

26 41 14 AV5 D

26 52 14 AV2 D

26 83 13 AV2 D

26 114 13 AV2 D

27 8

15 AV1 D

27 8

26 AV6 D

27 36 17 AV5 D

27 39 29 AV2 D

27 39 31 AV5 D

27 39 24 AV6 D

27 44 24 AV2 D

27 76 13 AV1 D

27 76 19 AV2 D

27 76 16 AV5 D

27 89 14 AV1 D

27 89 14 AV2 D

27 96 11 AV5 D

27 96 13 AV6 SG Row Col Per Locn D

27 111 17 AV5 D

27 115 21 AV2 D

27 115 20 AV5 D

28 69 10 AV2 D

28 88 18 AV5 D

28 115 13 AV2 D

28 115 22 AV5 D

29 34 27 AV2 D

29 34 24 AV5 D

29 83 10 AV1 D

29 83 16 AV5 D

29 113 15 AV2 D

30 12 12 AV1 D

30 12 11 AV5 D

30 66 22 AV2 D

30 66 19 AV5 D

31 113 10 AV1 D

32 12 16 AV1 D

32 12 13 AV2 D

32 12 16 AV3 D

32 12 38 AV5 D

33 58 18 AV1 D

33 58 21 AV2 D

33 58 19 AV3 D

33 96 13 AV1 D

33 96 14 AV2 D

33 107 15 AV4 D

34 15 11 AV1 D

34 15 16 AV4 D

34 17 9

AV1 D

34 17 14 AV2 D

34 17 14 AV3 D

34 17 12 AV4 D

34 22 12 AV2 D

34 22 15 AV3 D

34 22 12 AV4 D

34 22 12 AV5 D

34 22 15 AV6 D

34 30 14 AV3 D

34 30 13 AV5 D

34 35 13 AV2 D

34 35 12 AV5 D

34 40 13 AV4 SG Row Col Per Locn D

34 40 17 AV5 D

34 40 19 AV6 D

34 43 16 AV2 D

34 48 15 AV5 D

34 50 14 AV2 D

34 50 15 AV3 D

34 69 24 AV2 D

34 69 22 AV3 D

34 69 33 AV4 D

34 69 31 AV5 D

34 69 12 AV6 D

34 70 16 AV2 D

34 71 19 AV2 D

34 73 36 AV2 D

34 73 27 AV3 D

34 73 32 AV4 D

34 73 28 AV5 D

34 73 18 AV6 D

34 75 11 AV3 D

34 76 15 AV2 D

34 76 17 AV3 D

34 76 17 AV4 D

34 76 19 AV5 D

34 92 10 AV4 D

34 103 18 AV3 D

34 109 21 AV5 D

35 22 11 AV3 D

35 22 11 AV4 D

35 22 9

AV6 D

35 37 24 AV2 D

35 37 17 AV3 D

35 37 12 AV6 D

35 51 13 AV1 D

35 51 11 AV2 D

35 51 13 AV4 D

35 53 14 AV3 D

35 53 12 AV4 D

35 69 31 AV2 D

35 69 33 AV3 D

35 69 18 AV4 D

35 69 14 AV5 D

35 69 14 AV6 D

35 71 10 AV1 Page 19 of 22

APPENDIX B - OR19 List of Imperfections (non-SCC)

SG Row Col Per Locn D

35 71 19 AV2 D

35 71 15 AV3 D

35 83 24 AV3 D

35 83 21 AV4 D

35 86 11 AV4 D

35 86 14 AV6 D

35 88 13 AV2 D

35 88 13 AV3 D

35 88 19 AV4 D

35 89 21 AV2 D

35 89 17 AV3 D

36 16 16 AV3 D

36 40 21 AV2 D

36 40 19 AV3 D

36 40 18 AV4 D

36 40 15 AV5 D

36 40 16 AV6 D

36 41 20 AV2 D

36 46 14 AV5 D

36 67 23 AV2 D

36 67 11 AV3 D

36 80 11 AV3 D

36 82 15 AV1 D

36 82 26 AV2 D

36 82 18 AV3 D

36 82 22 AV4 D

36 82 23 AV5 D

36 90 14 AV2 D

37 16 15 AV1 D

37 16 11 AV2 D

37 16 22 AV3 D

37 16 18 AV4 D

37 16 12 AV5 D

37 16 15 AV6 D

37 19 9

AV6 D

37 38 13 AV2 D

37 38 13 AV3 D

37 38 20 AV4 D

37 38 12 AV5 D

37 39 15 AV2 D

37 39 17 AV3 D

37 39 19 AV4 D

37 39 18 AV5 SG Row Col Per Locn D

37 39 13 AV6 D

37 40 13 AV3 D

37 40 14 AV4 D

37 40 13 AV6 D

37 45 20 AV2 D

37 45 14 AV3 D

37 45 14 AV4 D

37 45 13 AV5 D

37 48 13 AV1 D

37 48 13 AV2 D

37 48 21 AV3 D

37 48 16 AV4 D

37 48 13 AV5 D

37 48 11 AV6 D

37 58 26 AV2 D

37 58 19 AV3 D

37 59 17 AV2 D

37 59 14 AV3 D

37 59 20 AV4 D

37 59 11 AV5 D

37 73 15 AV2 D

37 77 16 AV1 D

37 77 22 AV2 D

37 77 30 AV3 D

37 77 32 AV4 D

37 77 18 AV5 D

37 84 13 AV4 D

37 84 19 AV6 D

37 105 14 AV4 D

38 35 18 AV6 D

38 73 21 AV2 D

38 73 17 AV3 D

38 73 19 AV4 D

38 73 15 AV5 D

39 18 12 AV1 D

39 18 17 AV4 D

39 18 20 AV5 D

39 19 13 AV2 D

39 19 19 AV3 D

39 24 16 AV2 D

39 36 11 AV5 D

39 38 10 AV3 D

39 41 15 AV2 SG Row Col Per Locn D

39 41 18 AV3 D

39 41 26 AV4 D

39 41 18 AV5 D

39 41 13 AV6 D

39 44 15 AV1 D

39 44 17 AV3 D

39 44 21 AV4 D

39 44 17 AV5 D

39 44 16 AV6 D

39 50 16 AV2 D

39 50 18 AV3 D

39 50 16 AV4 D

39 50 18 AV5 D

39 57 13 AV1 D

39 57 22 AV2 D

39 57 22 AV3 D

39 57 13 AV4 D

39 57 20 AV5 D

39 59 15 AV3 D

39 62 25 AV2 D

39 74 15 AV2 D

39 75 17 AV2 D

39 82 13 AV1 D

39 82 21 AV2 D

39 82 19 AV3 D

39 82 17 AV4 D

39 82 16 AV5 D

39 89 21 AV1 D

39 89 17 AV2 D

39 94 15 AV2 D

39 94 14 AV3 D

39 94 13 AV4 D

39 96 11 AV5 D

39 102 17 AV1 D

39 103 20 AV1 D

39 103 18 AV2 D

40 19 12 AV1 D

40 21 18 AV2 D

40 21 16 AV3 D

40 21 15 AV6 D

40 23 15 AV1 D

40 23 14 AV4 D

40 24 15 AV2 Page 20 of 22

APPENDIX B - OR19 List of Imperfections (non-SCC)

SG Row Col Per Locn D

40 24 12 AV3 D

40 24 13 AV4 D

40 24 12 AV5 D

40 26 12 AV3 D

40 66 12 AV1 D

40 66 32 AV2 D

40 66 32 AV3 D

40 66 25 AV3 D

40 66 27 AV4 D

40 66 19 AV4 D

40 66 26 AV5 D

40 66 19 AV6 D

41 18 13 AV4 D

41 20 19 AV2 D

41 20 21 AV3 D

41 20 23 AV4 D

41 20 24 AV5 D

41 20 14 AV6 D

41 34 13 AV2 D

41 34 13 AV3 D

41 34 11 AV4 D

41 35 15 AV3 D

41 36 14 AV1 D

41 36 14 AV3 D

41 38 18 AV3 D

41 38 12 AV4 D

41 51 13 AV2 D

41 51 17 AV3 D

41 56 12 AV1 D

41 56 32 AV2 D

41 56 24 AV3 D

41 56 21 AV4 D

41 56 28 AV5 D

41 56 19 AV6 D

41 59 9

AV3 D

41 59 24 AV4 D

41 66 27 AV2 D

41 66 21 AV3 D

41 66 14 AV4 D

41 66 16 AV5 D

41 71 17 AV2 D

41 90 14 AV2 D

41 104 12 AV2 SG Row Col Per Locn D

41 104 11 AV5 D

42 19 11 03C D

42 19 14 AV1 D

42 19 17 AV3 D

42 19 14 AV4 D

42 19 13 AV5 D

42 20 12 AV6 D

42 24 13 AV1 D

42 24 15 AV2 D

42 24 13 AV3 D

42 24 26 AV4 D

42 24 12 AV5 D

42 37 21 AV2 D

42 37 20 AV3 D

42 37 13 AV4 D

42 37 12 AV6 D

42 39 16 AV3 D

42 39 13 AV3 D

42 39 20 AV4 D

42 39 17 AV4 D

42 40 19 AV6 D

42 46 14 AV2 D

42 46 24 AV3 D

42 46 16 AV4 D

42 46 22 AV5 D

42 47 17 AV2 D

42 47 17 AV3 D

42 47 17 AV4 D

42 47 18 AV5 D

42 77 17 AV5 D

42 92 15 AV1 D

42 92 13 AV2 D

42 92 14 AV3 D

42 92 16 AV4 D

42 92 20 AV5 D

42 92 17 AV6 D

42 98 13 AV3 D

42 98 14 AV4 D

42 98 16 AV5 D

42 98 14 AV6 D

43 21 15 AV2 D

43 21 23 AV3 D

43 21 15 AV4 SG Row Col Per Locn D

43 21 23 AV5 D

43 21 26 AV6 D

43 22 10 AV4 D

43 24 11 AV2 D

43 24 11 AV3 D

43 24 11 AV5 D

43 49 14 AV3 D

43 51 17 AV2 D

43 51 13 AV3 D

43 51 15 AV4 D

43 51 25 AV5 D

43 54 18 AV2 D

44 26 16 AV1 D

44 26 19 AV2 D

44 26 15 AV3 D

44 26 22 AV4 D

44 26 12 AV5 D

44 36 17 AV1 D

44 36 17 AV2 D

44 36 21 AV3 D

44 45 14 AV2 D

44 45 14 AV3 D

44 45 24 AV5 D

44 45 17 AV6 D

44 48 18 AV2 D

44 48 31 AV3 D

44 48 23 AV4 D

44 48 22 AV5 D

44 48 16 AV6 D

44 69 13 AV2 D

44 91 27 AV2 D

44 91 33 AV3 D

44 91 30 AV4 D

44 91 29 AV5 D

44 91 16 AV6 D

44 101 16 AV3 D

44 102 13 AV5 D

45 27 14 AV5 D

45 40 16 AV5 D

45 40 17 AV6 D

45 66 12 AV1 D

45 66 20 AV2 D

46 25 14 AV4 Page 21 of 22

APPENDIX B - OR19 List of Imperfections (non-SCC)

SG Row Col Per Locn D

46 25 19 AV5 D

46 25 18 AV6 D

46 30 18 AV3 D

46 30 29 AV4 D

46 30 31 AV5 D

46 32 13 AV2 D

46 32 14 AV6 D

46 38 14 AV2 D

46 38 18 AV3 D

46 38 37 AV4 D

46 38 35 AV5 D

46 38 17 AV6 D

46 39 20 AV4 D

46 39 39 AV5 D

46 39 18 AV6 D

46 42 25 AV4 D

46 42 27 AV5 D

46 42 15 AV6 D

46 60 21 AV4 D

46 98 9

AV3 D

47 28 11 AV4 D

47 49 35 AV2 D

47 49 24 AV3 D

47 53 20 AV4 D

47 53 27 AV5 D

47 53 19 AV6 D

47 61 22 AV4 D

47 61 19 AV6 D

47 92 17 AV3 D

47 97 16 AV3 D

47 97 15 AV5 D

48 65 20 AV4 D

49 27 13 AV3 D

49 28 20 AV5 D

49 28 14 AV6 D

49 36 13 AV2 D

49 36 16 AV4 D

49 36 15 AV5 D

49 36 15 AV6 D

49 41 13 AV2 D

49 42 16 AV6 D

49 43 15 AV1 D

49 43 14 AV2 SG Row Col Per Locn D

49 43 15 AV5 D

49 52 17 AV1 D

49 52 36 AV2 D

49 52 28 AV3 D

49 52 24 AV4 D

49 52 18 AV5 D

49 52 20 AV6 D

49 55 13 AV1 D

49 55 18 AV2 D

49 55 14 AV3 D

49 81 28 AV4 D

49 81 23 AV5 D

49 82 15 AV6 D

49 87 14 AV3 D

49 87 18 AV4 D

49 93 13 AV6 D

49 94 15 AV1 D

49 94 15 AV2 D

49 94 12 AV3 D

49 94 21 AV5 D

49 94 19 AV6 D

50 44 19 AV2 D

50 44 15 AV3 D

50 50 24 AV4 D

50 89 14 AV6 D

50 93 12 AV5 D

50 94 13 AV4 D

50 94 20 AV5 D

50 94 26 AV6 D

51 62 12 AV2 D

52 33 14 AV1 D

52 33 19 AV3 D

52 33 32 AV4 D

52 33 20 AV5 D

52 33 20 AV6 D

52 35 18 AV2 D

52 35 27 AV3 D

52 35 16 AV4 D

52 35 30 AV5 D

52 35 16 AV6 D

53 34 11 AV4 D

53 43 12 AV2 D

53 62 13 AV1 SG Row Col Per Locn D

53 89 17 AV6 D

54 43 16 AV2 D

54 43 16 AV4 D

54 58 11 AV2 D

55 39 9

AV3 D

55 41 11 AV2 D

55 76 9

AV4 D

55 82 15 AV2 D

56 41 26 AV2 D

56 41 9

AV3 D

56 41 30 AV4 D

56 41 25 AV5 D

56 41 19 AV6 D

56 43 13 AV2 D

56 43 13 AV3 D

56 65 19 AV3 D

56 69 16 AV3 D

56 69 19 AV4 D

56 69 26 AV5 D

56 69 21 AV6 D

56 81 19 AV5 D

56 81 18 AV6 D

56 82 13 AV5 D

56 82 15 AV6 D

57 72 8

AV5 D

58 58 11 AV1 D

58 58 11 AV6 D

58 75 18 AV2 D

58 75 14 AV5 D

58 75 17 AV6 D

59 59 14 AV5 D

59 60 12 AV1 D

59 62 12 AV5 D

59 66 11 AV1 Page 22 of 22