TSTF-471-A, Rev. 1 CEOG-172, Rev. 0 NUREGs Affected:
Eliminate use of term CORE ALTERATIONS in ACTIONS and Notes Technical Specification Task Force Improved Standard Technical Specifications Change Traveler 1430 1431 1432 1433 1434 Classification: 1) Technical Change Recommended for CLIIP?:
Industry
Contact:
Brian Woods, (949) 368-7621, woodsbl@songs.sce.com Yes Correction or Improvement:
Improvement NRC Fee Status:
Not Exempt Benefit:
Prevents Unnecessary Actions See attached.
Revision History OG Revision 0 Revision Status: Closed Original Issue Revision
Description:
Revision Proposed by:
CEOG Owners Group Review Information Date Originated by OG:
28-Jun-03 Owners Group Comments (No Comments)
Date: 29-Jul-03 Owners Group Resolution:
Approved TSTF Review Information TSTF Received Date:
29-Jul-03 Date Distributed for Review 18-Sep-03 TSTF Comments:
Remarked on Rev. 3 pages.
Date: 22-Apr-04 TSTF Resolution:
Superceeded OG Review Completed:
BWOG CEOG WOG BWROG TSTF Revision 1 Revision Status: Active Revised to be consistent with the Calvert Cliffs lead plant submittal. Changed Nuclear Instrumentation Required Action A.1 to prohibit positive reactivity additions instead of being deleted.
Revision
Description:
Revision Proposed by:
Calvert Cliffs TSTF Review Information TSTF Received Date:
23-Sep-05 Date Distributed for Review 18-Dec-06 Traveler Rev. 3. Copyright (C) 2006, EXCEL Services Corporation. Use by EXCEL Services associates, utility clients, and the U.S. Nuclear Regulatory Commission is granted. All other use without written permission is prohibited.
TSTF-471-A, Rev. 1 CEOG-172, Rev. 0 Affected Technical Specifications TSTF Revision 1 Revision Status: Active TSTF Comments:
(No Comments)
Date: 23-Sep-05 TSTF Resolution:
Approved OG Review Completed:
BWOG CEOG WOG BWROG NRC Review Information NRC Received Date:
07-Jun-05 TSTF-471 was a T Traveler submitted by Calvert Cliffs and subsequently approved for general use by the NRC.
07-Dec-06 NRC Approves NRC Comments:
Final Resolution:
Final Resolution Date:
Date of NRC Letter:
07-Dec-06 1.1 Delete "CORE ALTERATIONS" Change
Description:
Definitions Action 3.8.2.A A.C. Sources - Shutdown Action 3.8.2.A Bases A.C. Sources - Shutdown Action 3.8.2.B A.C. Sources - Shutdown Action 3.8.2.B Bases A.C. Sources - Shutdown Action 3.8.5.B DC Sources - Shutdown Action 3.8.5.B Bases DC Sources - Shutdown Action 3.8.8.A Inverters - Shutdown Action 3.8.8.A Bases Inverters - Shutdown Action 3.8.10.A Distribution Systems - Shutdown Action 3.8.10.A Bases Distribution Systems - Shutdown Action 3.9.1.A Boron Concentration Action 3.9.1.A Bases Boron Concentration Action 3.9.2.A NUREG(s)- 1430 1432 Only Nuclear Instrumentation Action 3.9.2.A Bases NUREG(s)- 1430 1432 Only Nuclear Instrumentation Action 3.9.2.B Bases NUREG(s)- 1430 1432 Only Nuclear Instrumentation 18-Dec-06 Traveler Rev. 3. Copyright (C) 2006, EXCEL Services Corporation. Use by EXCEL Services associates, utility clients, and the U.S. Nuclear Regulatory Commission is granted. All other use without written permission is prohibited.
TSTF-471-A, Rev. 1 CEOG-172, Rev. 0 LCO 3.9.3 Bases NUREG(s)- 1430 1432 Only Containment Penetrations Action 3.9.2.A NUREG(s)- 1431 Only Unborated Water Source Isolation Valves Action 3.9.2.A Bases NUREG(s)- 1431 Only Unborated Water Source Isolation Valves Action 3.9.3.A NUREG(s)- 1431 Only Nuclear Instrumentation Action 3.9.3.A Bases NUREG(s)- 1431 Only Nuclear Instrumentation Action 3.9.3.B Bases NUREG(s)- 1431 Only Nuclear Instrumentation S/A 3.9.4 Bases NUREG(s)- 1431 Only Containment Penetrations LCO 3.9.4 Bases NUREG(s)- 1431 Only Containment Penetrations LCO 3.3.8 Bases NUREG(s)- 1432 Only CPIS (Digital)
SR 3.3.8.4 NUREG(s)- 1432 Only CPIS (Digital)
SR 3.3.8.4 Bases NUREG(s)- 1432 Only CPIS (Digital)
S/A 3.9.3 Bases NUREG(s)- 1432 Only Containment Penetrations 18-Dec-06 Traveler Rev. 3. Copyright (C) 2006, EXCEL Services Corporation. Use by EXCEL Services associates, utility clients, and the U.S. Nuclear Regulatory Commission is granted. All other use without written permission is prohibited.
TSTF-471, Rev. 1 Page 1 of 7 1.0 Description In the PWR ITS NUREGs (NUREG-1430-1432), the defined term CORE ALTERATIONS appears in the Required Actions and Surveillance Notes of less than 10 specifications. It is not used in any Applicability statements. Suspending CORE ALTERATIONS or exempting testing except during CORE ALTERATIONS has no effect on the initial conditions or mitigation of any Design Basis Accident (DBA) or transient, and these requirements apply an operational burden with no corresponding safety benefit. Therefore, the uses of the defined term CORE ALTERATIONS are removed from the Technical Specifications.
2.0 Proposed Change The proposed change eliminates the defined term CORE ALTERATIONS from NUREG-1430, 1431, and 1432 and all uses of the term from the Specifications and Bases. This affects the following Specifications:
NUREG-1430, 1431, and 1432 3.8.2, A.C. Sources - Shutdown 3.8.5, D.C. Sources - Shutdown 3.8.8, Inverters - Shutdown 3.8.10, Distribution Systems - Shutdown 3.9.1, Boron Concentration 3.9.2 or 3.9.3, Nuclear Instrumentation NUREG-1431 3.9.2, Unborated Water Source Isolation Valves NUREG-1432 SR 3.3.8.4, CPIS (Digital)
The BWR ITS NUREGs, NUREG-1433 and 1434, make extensive use of the term CORE ALTERATIONS in Applicability statements, ACTIONS, and Surveillances, and especially in the Special Operations Specifications. Therefore, the BWR ITS NUREGs are not modified by this change.
The Bases of each of the affected Specifications described above are revised to reflect the changes made.
3.0 Background
CORE ALTERATIONS is defined in the CEOG NUREG as, CORE ALTERATION shall be the movement of any fuel, sources, or reactivity control components [excluding control element assemblies (CEAs) withdrawn into the upper guide structure], within the reactor vessel with the vessel head removed and fuel in the vessel. Suspension of CORE ALTERATIONS shall not preclude completion of movement of a component to a safe position. In the WOG and BWOG NUREGs it is defined as, CORE ALTERATION shall be the movement of any fuel, sources, or
TSTF-471, Rev. 1 Page 2 of 7 reactivity control components, within the reactor vessel with the vessel head removed and fuel in the vessel. Suspension of CORE ALTERATIONS shall not preclude completion of movement of a component to a safe position.
TSTF-51, Revise containment requirements during handling irradiated fuel and core alterations, eliminated all uses of the defined term CORE ALTERATIONS from Applicability statements in the PWR NUREGs and most uses of CORE ALTERATIONS in Required Actions.
This Traveler eliminates the few remaining instances of the defined term CORE ALTERATIONS from the PWR ITS NUREGs.
4.0 Technical Analysis The term core alteration does not appear in the Standard Review Plan or in Title 10 of the Code of Federal Regulations. Since CORE ALTERATIONS only occur when the reactor vessel head is removed, it only applies in MODE 6. There are only two accidents considered during MODE 6 for PWRs: a fuel handling accident and a boron dilution accident. According to the Standard Review Plan, a fuel handling accident is initiated by the dropping of a [recently]
irradiated fuel assembly, either in the containment or in the fuel building. There are no mitigation actions, except some plants credit ventilation systems to reduce the dose consequences. Suspension of CORE ALTERATIONS, except for suspension of movement of
[recently] irradiated fuel, will not prevent or impair the mitigation of a fuel handling accident.
The second analyzed event is a boron dilution accident. A boron dilution accident is initiated by a dilution source which results in the boron concentration dropping below that required to maintain the SHUTDOWN MARGIN. As described in the Bases of Specification 3.9.1, Boron Concentration, (which applies in MODE 6), The refueling boron concentration limit is specified in the COLR. Unit procedures ensure the specified boron concentration in order to maintain an overall core reactivity of keff 0.95 during fuel handling, with control element assemblies (CEAs) and fuel assemblies assumed to be in the most adverse configuration (least negative reactivity) allowed by unit procedures. The accident is mitigated by stopping the dilution. Suspension of CORE ALTERATIONS has no effect on the mitigation of a boron dilution accident. Movement of control rods or fuel do not affect the initial conditions of a boron dilution accident as it is assumed that the control rods and fuel are in the most adverse conditions with a large safety margin (keff 0.95). To address the possibility of a misloaded fuel assembly in Technical Specification 3.9.2, a Required Action is added that suspends positive reactivity additions if nuclear instrumentation is not available. This precludes movement of fuel assemblies which could add reactivity to the core.
In summary, with the exception of suspending movement of [recently] irradiated fuel assemblies, there are no DBAs or transients that are initiated by, or mitigation affected by, suspension of CORE ALTERATIONS. Therefore, if all Required Actions that require suspension of CORE ALTERATIONS also require suspension of movement of [recently] irradiated fuel, suspension of CORE ALTERATIONS provides no safety benefit.
The term CORE ALTERATION is used in the following Specifications:
TSTF-471, Rev. 1 Page 3 of 7 NUREG-1430, 1431, and 1432 3.8.2, A.C. Sources - Shutdown 3.8.5, D.C. Sources - Shutdown 3.8.8, Inverters - Shutdown 3.8.10, Distribution Systems - Shutdown 3.9.1, Boron Concentration 3.9.2 or 3.9.3, Nuclear Instrumentation NUREG-1431 3.9.2, Unborated Water Source Isolation Valves NUREG-1432 SR 3.3.8.4, CPIS (Digital)
An analysis of elimination of the defined term CORE ALTERATIONS for each of these Specifications is given below.
3.8.2, 3.8.5, 3.8.8, and 3.8.10 If a required train of electrical power (A.C, D.C, Inverters, or Distribution Systems) is inoperable, the Required Actions require:
- Suspension of CORE ALTERATIONS
- Suspension of movement of [recently] irradiated fuel assemblies, and
- Suspension of operations involving positive reactivity additions that could result in loss of required SDM or boron concentration.
As discussed above, because the Required Actions require the suspension of movement of
[recently] irradiated fuel assemblies, the initiating conditions for a fuel handling accident are prohibited. Because the Required Actions require the suspension of positive reactivity additions that could result in a loss of SDM, the initial conditions for a boron dilution accident are prevented. Therefore, the action to suspend CORE ALTERATIONS provides no safety benefit and is not needed.
3.9.1 If boron concentration is not within limit, the Required Actions require immediate suspension of CORE ALTERATIONS, immediate suspension of positive reactivity additions, and immediate actions to restore the boron concentration within limits. This Specification is only concerned with a boron dilution accident, as SDM has no bearing on a fuel handling accident. Note that the Required Action to suspend positive reactivity additions would also prohibit adding fuel assemblies to the reactor, which could reduce the SDM. The requirement to suspend positive reactivity additions is the only action needed to mitigate a boron dilution event. Therefore, the action to suspend CORE ALTERATIONS provides no safety benefit and is not needed.
TSTF-471, Rev. 1 Page 4 of 7 3.9.2 or 3.9.3 (Nuclear Instrumentation)
If a required source range neutron flux monitor is inoperable, CORE ALTERATIONS must be suspended and operations that would cause introduction into the RCS, coolant with boron concentration less than required to meet the boron concentration of LCO 3.9.1. An inoperable source range detector has no effect on the initiation or mitigation of a fuel handling accident.
Suspending introduction of RCS coolant at less than the required boron concentration prevents a boron dilution accident. Therefore, suspension of CORE ALTERATIONS does nothing to prevent any analyzed accident. It is a good practice to not move fuel with less than a full complement of source range detectors. Therefore, Required Action A.1 is revised to preclude positive reactivity additions. However, as stated in 10 CFR 50.36(b), The technical specifications will be derived from the analyses and evaluation included in the safety analysis report, and amendments thereto, submitted pursuant to § 50.34. Suspension of CORE ALTERATIONS in this circumstance is not based on the analyses in the safety analysis report and that Required Action is removed.
3.9.2 (Unborated Water Source Isolation Valves) (NUREG-1431 only)
If one or more unborated water source isolation valves are not secured in the closed position, CORE ALTERATIONS must be suspended and actions taken to secure the valve in the closed position. The purpose of this Specification is to prevent a boron dilution accident. CORE ALTERATIONS have no effect on a boron dilution accident, either as an initiator or as mitigation. Suspending CORE ALTERATIONS when a valve is not secured does not provide compensation or reduce the probability of the event. Therefore, the action to suspend CORE ALTERATIONS provides no safety benefit and is not needed.
SR 3.3.8.4 (CEOG only)
LCO 3.3.8 is applicable in MODES 1, 2, 3, and 4 and during movement of [recently] irradiated fuel assemblies within containment. SR 3.3.8.4 is modified by a NOTE which states, Only required to be met during CORE ALTERATIONS or during movement of irradiated fuel assemblies within containment. This Note is inconsistent with the Applicability. The reference to CORE ALTERATIONS in the Note was overlooked and should have been deleted by TSTF-51, which eliminated CORE ALTERATIONS from the Applicability.
As stated in the Bases of Specification 3.3.8, The CPIS provides protection from the release of radioactive contamination from the containment in the event a fuel assembly should be severely damaged during handling. The SR Note requirement that the SR must be met during movement of irradiated fuel assemblies within containment is consistent with the Appliability and ensures the SR is met when there is a possibility of a fuel handling accident. Therefore, elimination of the CORE ALTERATION portion of the SR Note will have no effect on the applicability of the SR.
TSTF-471, Rev. 1 Page 5 of 7 Other Changes
- 1) With the elimination of all uses of the defined term, CORE ALTERATION, the definition in Section 1.1 is removed.
- 2) The LCO section of the Bases of Specification 3.3.8 incorrectly states that a channel of CPIS is required during CORE ALTERATIONS and movement of irradiated fuel assemblies. The Specification requires a channel of CPIS is required during movement of irradiated fuel assemblies. The Bases are corrected to be consistent with the Specifications.
- 3) The Applicable Safety Analysis and LCO sections of the Bases of Specification 3.9.3, Containment Penetration, make statements regarding CORE ALTERATIONS that are incorrect and inconsistent with the Specifications. The references to CORE ALTERATIONS were overlooked and should have been deleted by TSTF-51, which eliminated CORE ALTERATIONS from the Applicability of the Specification.
Benefits of Elimination There are several benefits to eliminating the ACTIONS and SR Note which reference CORE ALTERATIONS.
The term CORE ALTERATIONS unnecessarily complicates plant operation. Plants go to great lengths to ensure that no prohibited CORE ALTERATIONS take place, such as pausing the lift of the reactor vessel head and having individuals lay on the floor or use video cameras to look under the head to ensure that no control rod drive mechanisms are still latched to avoid accidentally lifting a control rod and violating a Required Action which prohibits CORE ALTERATIONS. These actions have no safety benefit as the boron concentration limit ensures adequate SDM even with the worst configuration of control rods. These actions result in increased personnel dose and provide no safety benefit.
There are a large number of reportable events regarding CORE ALTERATIONS. A review of Licensee Event Reports between 1995 and the present revealed 12 LERs related to failure to suspend CORE ALTERATIONS. As described above, these action have no effect on plant safety and distract the plant and the NRC from more safety significant issues.
5.0 Regulatory Analysis 5.1 No Significant Hazards Consideration The TSTF has evaluated whether or not a significant hazards consideration is involved with the proposed generic change by focusing on the three standards set forth in 10 CFR 50.92, Issuance of amendment, as discussed below:
- 1. Does the proposed change involve a significant increase in the probability or consequences of an accident previously evaluated?
TSTF-471, Rev. 1 Page 6 of 7 Response: No.
The proposed change eliminates the use of the term CORE ALTERATIONS from NUREG-1430, -1431, and -1432, all Required Actions requiring suspension of CORE ALTERATIONS, and reference to CORE ALTERATIONS in a Surveillance Note in NUREG-1432. CORE ALTERATIONS are not an initiator of any accident previously evaluated except a fuel handling accident. Those revised Specifications which protect the initial conditions of a fuel handling accident also require the suspension of movement of
[recently] irradiated fuel assemblies. This Required Action protects the initial conditions of a fuel handling accident and, therefore, suspension of CORE ALTERATIONS is not required.
Suspension of CORE ALTERATIONS does not provide mitigation of any accident previously evaluated. Therefore, CORE ALTERATIONS do not affect the initiators of the accidents previously evaluated and suspension of CORE ALTERATIONS does not affect the mitigation of the accidents previously evaluated.
Therefore, the proposed change does not involve a significant increase in the probability or consequences of an accident previously evaluated.
- 2. Does the proposed change create the possibility of a new or different kind of accident from any accident previously evaluated?
Response: No.
No new or different accidents result from utilizing the proposed change. The changes do not involve a physical alteration of the plant (i.e., no new or different type of equipment will be installed) or a significant change in the methods governing normal plant operation. In addition, the changes do not impose any new or different requirements. The changes do not alter assumptions made in the safety analysis. The proposed changes are consistent with the safety analysis assumptions.
Therefore, the proposed change does not create the possibility of a new or different kind of accident from any previously evaluated.
- 3. Does the proposed change involve a significant reduction in a margin of safety?
Response: No.
Only two accidents are postulated to occur in the plant conditions in which CORE ALTERATIONS may be made: a fuel handling accident and a boron dilution accident.
Suspending movement of irradiated fuel assemblies prevents a fuel handling accident. Also requiring the suspension of CORE ALTERATIONS is an overly broad, redundant requirement that does not increase the margin of safety. CORE ALTERATIONS have no effect on a boron dilution accident. Core components are not involved in the creation or mitigation of a boron dilution accident and the SHUTDOWN MARGIN limit is based on assuming the worst-case configuration of the core components. Therefore, CORE ALTERATIONS have no effect on the margin of safety related to a boron dilution accident.
TSTF-471, Rev. 1 Page 7 of 7 Therefore, the proposed change does not involve a significant reduction in a margin of safety.
Based on the above, the TSTF concludes that the proposed change presents no significant hazards consideration under the standards set forth in 10 CFR 50.92(c), and, accordingly, a finding of no significant hazards consideration is justified.
5.2 Applicable Regulatory Requirements / Criteria In conclusion, based on the considerations discussed above, (1) there is reasonable assurance that the health and safety of the public will not be endangered by operation in the proposed manner, (2) such activities will be conducted in compliance with the Commissions regulations, and (3) the approval of the proposed change will not be inimical to the common defense and security or to the health and safety of the public.
6.0 Environmental Consideration A review has determined that the proposed change would change a requirement with respect to installation or use of a facility component located within the restricted area, as defined in 10 CFR 20, or would change an inspection or surveillance requirement. However, the proposed change does not involve (i) a significant hazards consideration, (ii) a significant change in the types or significant increase in the amounts of any effluent that may be released offsite, or (iii) a significant increase in individual or cumulative occupational radiation exposure. Accordingly, the proposed change meets the eligibility criterion for categorical exclusion set forth in 10 CFR 51.22(c)(9). Therefore, pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment need be prepared in connection with the proposed change.
7.0 References None.
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1
TSTF-471, Rev. 1