COL Docs - (External_Sender) 4/11/19 Public Meeting Slides for Environmental Conditions for Inputs to Civil/Structural Design Topic
ML19091A261
Person / Time
Site: Vogtle  Southern Nuclear icon.png
Issue date: 04/01/2019
From:
- No Known Affiliation
To:
References
Download: ML19091A261 (21)


Text

1 Vogtle PEmails From:

Arafeh, Yasmeen N. <YNARAFEH@southernco.com>

Sent:

Monday, April 1, 2019 10:58 AM To:

Patel, Chandu; Habib, Donald; Gleaves, Bill Cc:

Agee, Stephanie Y.; Chamberlain, Amy Christine; Aughtman, Amy G.;

'harperzs@westinghouse.com'; Wu, Si

Subject:

[External_Sender] 4/11/19 Public Meeting Slides for Environmental Conditions for Inputs to Civil/Structural Design Topic Attachments:

APP-GW-GLY-172.pdf Chandu, Don, and Billy:

The attached document is provided for the Public Meeting on Thursday, April 11, 2019.

Best, Yasmeen Arafeh Nuclear Development, Licensing Work: (205)992-7190 ynarafeh@southernco.com

Hearing Identifier:

Vogtle_COL_Docs_Public Email Number:

438 Mail Envelope Properties (BN8PR04MB563593A0C3106112CD298574BB550)

Subject:

[External_Sender] 4/11/19 Public Meeting Slides for Environmental Conditions for Inputs to Civil/Structural Design Topic Sent Date:

4/1/2019 10:57:51 AM Received Date:

4/1/2019 11:01:05 AM From:

Arafeh, Yasmeen N.

Created By:

YNARAFEH@southernco.com Recipients:

"Agee, Stephanie Y." <SYAGEE@southernco.com>

Tracking Status: None "Chamberlain, Amy Christine" <ACCHAMBE@southernco.com>

Tracking Status: None "Aughtman, Amy G." <AGAUGHTM@SOUTHERNCO.COM>

Tracking Status: None

"'harperzs@westinghouse.com'" <HARPERZS@WESTINGHOUSE.COM>

Tracking Status: None "Wu, Si" <wu1s@westinghouse.com>

Tracking Status: None "Patel, Chandu" <Chandu.Patel@nrc.gov>

Tracking Status: None "Habib, Donald" <Donald.Habib@nrc.gov>

Tracking Status: None "Gleaves, Bill" <Bill.Gleaves@nrc.gov>

Tracking Status: None Post Office:

BN8PR04MB5635.namprd04.prod.outlook.com Files Size Date & Time MESSAGE 229 4/1/2019 11:01:05 AM image001.png 1723 APP-GW-GLY-172.pdf 552526 Options Priority:

Standard Return Notification:

No Reply Requested:

Yes Sensitivity:

Normal Expiration Date:

Recipients Received:

Westinghouse Non-Proprietary Class 3 1

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

1 April 11, 2019 Westinghouse Electric Company LLC LAR-132: Environmental Conditions for Inputs to Civil/Structural Design -

NRC Technical Exchange Meeting

2

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

Westinghouse Non-Proprietary Class 3 Meeting Purpose Technical exchange meeting to discuss the proposed changes in LAR-132 Receive and address Staff feedback Agenda Background Information Approach to the licensing basis markups Proposed Changes Applicable Regulatory Requirements Meeting Purpose and Agenda The information in this presentation is preliminary and will be finalized prior to LAR submittal.

3

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

Westinghouse Non-Proprietary Class 3 Background Information

  • The thermal loads are design basis loads in AP1000 licensing basis for seismic category I structures.
  • UFSAR Table 3H.5-1 specifies the design temperatures for thermal gradient in Nuclear Island.
  • Thermal load inconsistencies exist between licensing basis and design documents. A design change package proposed to modify Table 3H.5-1 to align the inconsistencies.

4

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

Westinghouse Non-Proprietary Class 3 Approach to the licensing basis markups

  • UFSAR tables in Sections 3.8 and 3H show demands of critical sections.
  • During design certification, each table is determined what was included. Some of the tables include thermal loads in the demands, some of the tables exclude thermal loads from the demands through a thermal note.
  • The following tables include the thermal loads in the demands: 3.8.3-3, 3.8.3-4, 3.8.3-5, 3.8.3-6, 3.8.3-7, 3H.5-2, 3H.5-4, 3H.5-6, 3H.5-8, 3H.5-9 Sheet 3, 3H.5-10, 3H.5-14, and 3H.5-15.
  • The following tables do not include the thermal loads as result of the thermal note: 3.8.5-3, 3H.5-3, 3H.5-5, 3H.5-7, 3H.5-9 Sheets 1-2c, 3H.5-11, 3H.5-12, and 3H.5-13.

Approach in the current licensing basis is maintained in LAR-132 markups.

Thermal note in the licensing basis tables

5

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

Westinghouse Non-Proprietary Class 3 Change No.1: Shield Building PCS Tank Normal Thermal Change Reason for the Change

  • There is an inconsistency of the normal thermal load for the PCS tank between UFSAR Subsection 3H.3.3 & Table 3H.5-1 and UFSAR Table 6.2.2-1 & Technical Specification.

UFSAR Table 6.2.2-1 and COL Appendix A SR 3.6.6.1 define the minimum temperature in PCS tank is 40 °F.

PCS recirculation heater keeps water in the PCS tank at minimum of 40 °F.

UFSAR Subsection 3H.3.3 and Table 3H.5-1 show the water in PCS tank is 70 °F.

Proposed Changes:

  • Revise the normal thermal load for the PCS Tank in UFSAR Subsection 3H.3.3 and Table 3H.5-1 to be consistent with other sections in UFSAR and design documents. (+70 °)°F)
  • No involved changes to critical sections.
  • No impact on the PCS system.

6

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

Westinghouse Non-Proprietary Class 3 Change No.1: Shield Building PCS Tank Normal Thermal Change

  • Revise the normal thermal inside PCS tank from +70°F to +40°F in UFSAR Subsection 3H.3.3 and Table 3H.5-1.

Tier 2* text in Subsection 3H.3.3 Table 3H.5-1

7

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

Westinghouse Non-Proprietary Class 3 Change No.1: Shield Building PCS Tank Normal Thermal Change - Involved Sections

  • PCS Tank Exterior Wall: No impact on Table 3H.5-9 Sheet 3 Table shows combined SSE + Normal Thermal; No thermal note; No impact on the table.

8

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

Westinghouse Non-Proprietary Class 3 Change No.1: Shield Building PCS Tank Normal Thermal Change - Involved Sections

  • SB Roof: No impact on Table 3H.5-15 Table shows combined SSE + Normal Thermal; No thermal note; No impact on the table.

9

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

Westinghouse Non-Proprietary Class 3 Change No.2: MSIV Room Accident Thermal Change Reason for the Change

  • There is an inconsistency of accident surface temperature for the MSIV compartment between UFSAR Table 3H.5-1 and updated calculations.

Proposed Changes:

  • Revise the accident air temperature for the MSIV compartment in UFSAR Table 3H.5-1 to be consistent with UFSAR Figure 3D.5-9. (+132 °)°F)
  • Revise the accident surface temperature for the MSIV compartment in UFSAR Table 3H.5-1 to reflect the updated calculations. (+132 °)°F)
  • No involved changes to critical sections.
  • No impact on Equipment Qualification because no change to Figure 3D.5-9.
  • No impact on MSIV compartment pressurization.
  • No impact on structural design because existing structures have sufficient margin to accommodate this thermal loading.

10

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

Westinghouse Non-Proprietary Class 3 Change No.2: MSIV Room Accident Thermal Change

  • Revise the accident air temperature of MSIV room from +132°F to

+485°F and accident surface temperature from +132°F to +222°F in UFSAR Table 3H.5-1.

11

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

Westinghouse Non-Proprietary Class 3 Change No.2: MSIV Room Accident Thermal Change

- Involved Sections

  • No impact on critical section Wall 11 (North wall of aux)
  • No impact on critical section Wall L (East wall of east MSIV compartment)

12

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

Westinghouse Non-Proprietary Class 3 Change No.3: Auxiliary Building Exterior Walls below Grade and Basemat Accident Thermal Change Reason for the Change

  • Table 3D.5-4 defines the abnormal environments as a function of equipment location outside containment.
  • There is an inconsistency of accident thermal loads for the exterior walls below grade and basemat in auxiliary building between UFSAR Table 3H.5-1 and UFSAR Table 3D.5-4.

Proposed Changes:

  • Revise the accident thermal loads for the exterior walls below grade and basemat in auxiliary building in UFSAR Table 3H.5-1 to be consistent with UFSAR Table 3D.5- 15°F Outside/ +140 °F Inside)
  • Involved changes in Wall 1 Table 3H.5-2 (updating the governing load combination)
  • No impact on Equipment Qualification because no change to Table 3D.5-4.
  • No impact on structural design because existing structures have sufficient margin to accommodate the thermal loading.

13

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

Westinghouse Non-Proprietary Class 3 Change No.3: Auxiliary Building Exterior Walls below Grade and Basemat Accident Thermal Change

  • Revise the accident thermal for the exterior walls below grade and basemat in the auxiliary building from N/R to +50 °F Outside/ +140 °F Inside in UFSAR Table 3H.5-1.

14

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

Westinghouse Non-Proprietary Class 3 Change No.3: Auxiliary Building Exterior Walls below Grade and Basemat Accident Thermal Change - Involved Sections

  • Wall 1: Impact Table 3H.5-2.

Table shows governing load combinations at specific elevations.

No thermal note; Impact on the load combinations.

15

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

Westinghouse Non-Proprietary Class 3 Change No.3: Auxiliary Building Exterior Walls below Grade and Basemat Accident Thermal Change - Involved Sections

  • Wall 1: No Impact on Table 3H.5-3.

Table shows demands under mechanical loads with thermal note; No impact on the table.

16

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

Westinghouse Non-Proprietary Class 3 Change No.3: Auxiliary Building Exterior Walls below Grade and Basemat Accident Thermal Change - Involved Sections

  • Basemat: No impact on Table 3.8.5-3.

Table shows demands under mechanical loads with thermal note; No impact on the table.

17

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

Westinghouse Non-Proprietary Class 3 Applicable Regulatory Requirements

  • GDC 1 - Quality Standards and Records
  • GDC 2 - Design bases for protection against natural phenomena
  • GDC 4 - Environmental and dynamic effects design bases

18

© 2019 Westinghouse Electric Company LLC. All Rights Reserved.

Westinghouse Non-Proprietary Class 3 Questions/Discussion Discussion