RA-19-0092, Refuel 24 (C1R24) Inservice Inspection (ISI) and Steam Generator Inspection (SG-ISI) Report
| ML19070A068 | |
| Person / Time | |
|---|---|
| Site: | Catawba |
| Issue date: | 03/11/2019 |
| From: | Hare M Duke Energy Carolinas |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| RA-19-0092 | |
| Download: ML19070A068 (26) | |
Text
(-,DUKE ENERGY.
March 11, 2019 Serial: RA-19-0092 United States Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Catawba Nuclear Station, Unit No. 1 Docket No. 50-413 / Renewed License No. NPF-35 Mandy Hare Nuclear Support SeNices Manager Catawba Nuclear Station Duke Energy CN03CH I 4800 Concord Rd York, SC 29745 803,701.2218 Mandy.Hare@duke-ene,w.com
Subject:
Catawba Unit 1, Refuel 24 (C1R24) lnservice Inspection (ISi) and Steam Generator Inspection (SG-ISI) Report Ladies and Gentlemen:
In accordance with Section XI of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code, Duke Energy is providing its lnservice Inspection (ISi) for Catawba Nuclear Station, Unit No. 1, Refuel 24 (C 1 R24). Also included is the Steam Generator lnservice Inspection (SG-ISI) Summary for Catawba Nuclear Station, Unit No. 1, Refuel 24 (C1 R24). contains the C 1 R24 Owner's Activity Summary Report. contains the SG-ISI tube inspection report for C1 R24.
This submittal contains no regulatory commitments. Should you have any questions concerning this letter, or require additional information, please contact Art Zaremba, Manager - Nuclear Fleet Licensing, at 980-373-2062.
Sincerely, Mandy Hare Nuclear Support Services Manager, Catawba Nuclear Station
U.S. Nuclear Regulatory Commission Page 2 Serial: RA-19-0092 Enclosure(s):
- 1. Owners Activity Summary Report For Refueling Outage 24
- 2. Steam Generator Inservice Inspection Report For Refueling Outage 24 NDE cc:
(w/ all enclosures)
Michael Mahoney, NRC Project Manager, NRR cc:
(without SG data)
Catherine Haney, NRC Regional Administrator, Region II J.D. Austin, NRC Resident Inspector, Catawba Nuclear Station RA-19-0092 Owners Activity Summary Report for Refueling Outage 24
DUKE ENERGY INSERVICE INSPECTION
SUMMARY
REPORT UNIT 1 CATAWBA 2018 REFUELING OUTAGE Originated By:
Checked By:
Approved By:
C1R24 (Outage 3)
Location: 4800 Concord Road, York, SC, 29745 NRC Docket No. 50-413 Commercial Service Date: June 29, 1985 Owner: Duke Energy 526 South Church St.
Charlotte, NC 28201-1006 Revision 0 4--~
Austin C. Keller
~~~
Timothy D. Myers
~Afyne Date Date Date
- t/Jt/ I'/
~ I
~/:U./t'f z/2~/r°l
CASE N-532-5 FORM OAR-1 OWNER'S ACTIVITY REPORT Report Number ________
O_w_ne_r_'s_A_c_ti_v*~1ty~R_e~p_o_rt_f_o_r_R_e_f_u_e_lin~g~O_u_t_a-ge_C_1_R_2_4 _______ _
Plant Unit No.
Catawba Nuclear Station, 4800 Concord Road, York, SC 29745 Commercial service date __
J-'-u_n_e_2_9~, _19_8-'-5'--_
Refueling outage no. ---'-C_1_Rc...2_4 __ _
(if applicable)
Current inspection interval Fourth Inspection Interval (ISi), Third Inspection Interval (Containment ISi)
(1st, 2nd, 3rd, 4th. other)
Current inspection period Second Inspection Period (ISi and Containment ISi)
(1st, 2nd, 3rd)
Edition and Addenda of Section XI applicable to the inspection plans ASME Section XI 2007 Edition through 2008 Addenda Date and revision of inspection plans See Attachment - Page 2 Edition and Addenda of Section XI applicable to repair/replacement activities, if different than the inspection plans Same as above Code Cases used for inspection and evaluation:
The following Code Cases are permitted by the ISi Plan and Addenda:
4th Interval: N-513-3, N-532-5, N-586-1, N-600, N-613-1, N-639, N-643-2, N-648-1, N-651, N-705, N-706-1, N-712, N-716-1, N-722-1, N-729-4, N-731, N-735, N-747, N-751, N-765, N-770-2, N-771, N-776, N-786-1, N-798, N-800, N-805, N-823, N-825, & N-845 (if applicable)
CERTIFICATE OF CONFORMANCE I certify that (a) the statements made in this report are correct; (b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI; and (c) the repair/replacement activities and evaluations supporting the completion of C1 R24 conform to the requirements of Section XI.
(refueling outage number)
Signed Austin C. Keller, ISi Program Owner CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of South Carolina and employed by OneCIS Insurance Company Lynn. MA have inspected the items described in this Owner"s Activity Report, and state that, to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair/replacement activities and evaluation described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with th.is-in,._~
Date Page 1 of 4
CASE N-532-5 Page 2 of 4 Attachment Catawba Unit 1 Refuel Outage 24, Inservice Inspection Report Date and Revision of Inservice Inspection Plans:
I.
Fourth Interval Inservice Inspection Plans
- 1. The following documents comprise the Catawba Nuclear Station 4th Interval Inservice Inspection Plan for Unit 1 (Class 1, 2, and 3 Components):
- a. Catawba Nuclear Station Unit 1 and Unit 2 - Fourth Interval Inservice Inspection Plan, Document #CISI-1462.10-0040-ISI PLAN, Rev. 4, dated 01/14/2019.
- b. Fourth Interval Inservice Inspection Outage Schedule Catawba Nuclear Station Unit 1, Document #CISI-1462.10-0040-UNIT 1, Rev. 1, dated 02/06/2019.
- 2. The following documents comprise the Catawba Nuclear Station 4th Interval Inservice Inspection Pressure Test Plan for Unit 1:
- a. Catawba Nuclear Station Units 1 and 2 Fourth Inspection Interval Inservice Inspection Pressure Test Plan, Document #CISI-1462.20.0040-PTPlan, Rev. 1, dated 07/13/2017, including the following addenda:
- i. CISI-1462.20-0040-C1-PT-003 II.
Third Interval Containment Inservice Inspection Plan
- 1. The following document comprises the Catawba Nuclear Station 3rd Interval Containment Inservice Inspection Plan for Unit 1 (Class MC):
- a. Catawba Nuclear Station Units 1 and 2 - Third Interval Containment Inservice Inspection Plan, Document #CN-ISIC3-1042-0001, Rev. 8, dated 12/20/2018.
CASE N-532-5 Page 3 of 4 TABLE 1 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE Examination Category and Item Number Item Description Evaluation Description F-A / F1.12 C1-07668 / 1-R-NV-1932 VT-3 examination revealed excess U-bolt material outside the locking nuts bent. WR# 20127298 was written to remove excess material on the outside of the upper and lower locking nuts.
Engineering Evaluation found support to be acceptable. Reference NCR#
02245099.
F-A / F1.30 C1-06030 / 1-R-KC-0404 VT-3 examination revealed a loose jam nut. WR# 20126813 was written to tighten loose jam nut. Engineering Evaluation found support to be acceptable. Reference NCR#
02244153.
B-P / B15.10 Boric acid residue found on NC Pump 1C Seal Housing during ISI Pressure Test Zone, 1NC-001L-A Area identified in NCR# 02247880 was evaluated by Engineering and found to be acceptable.
B-P / B15.10 Boric acid residue found on Incore Instrumentation Tubing during ISI Pressure Test Zone, 1NC-001L-A Area identified in NCR# 02247870 was evaluated by Engineering and found to be acceptable.
B-P / B15.10 Boric acid residue found on NC Pump 1D Seal Housing and intermittent around the circumference of the pump during ISI Pressure Test Zone, 1NC-001L-A Area identified in NCR# 02247865 was evaluated by Engineering and found to be acceptable.
C-H / C7.10 Boric acid residue found on mechanical joint 1ND-1 MJ-2 (Class B Bolted Connection -
IWA-5241(f))
Area identified in NCR# 02245111 was evaluated by Engineering and found to be acceptable.
C-H / C7.10 Boric acid residue found on the 1A and 1B ND Heat Exchanger Flanges (Class B Bolted Connection - IWA-5241(f))
Areas identified in NCR# 02245630 was evaluated by Engineering and found to be acceptable.
C-H / C7.10 Boric acid residue found during ISI Pressure Test Zone, 1NV-006L-B Areas identified in NCR# 02147044 were evaluated by Engineering and found to be acceptable.
C-H / C7.10 Boric acid residue found during ISI Pressure Test Zone, 1NV-003L-B Areas identified in NCR# 02141397 were evaluated by Engineering and found to be acceptable.
CASE N-532-5 Page 4 of 4 TABLE 2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Code Class Item Description Description of Work Date Completed Repair /
Replacement Plan Number 3
Nuclear Sampling System weld 1492RN398-25 Repair weld 1492RN398-25 due to lack of penetration on the weld root 11/26/2018 20106077-01 RA-19-0092 Steam Generator Inservice Inspection Report for Refueling Outage 24
Steam Generator In-service Inspection Summary Report Catawba Nuclear Station Unit 1 CJR24 Fall Outage 2018 Location: Catawba Nuclear Station, 4800 Concord Road, York, SC 29745 NRC Docket No. 50-413 National Board No. 130 Commercial Service Date: June 29, 1985 Owner: Duke Energy Carolinas, LLC 526 South Church St.
Charlotte, N.C. 28202 Revision 0 Prepared By: Dan Mayes 9BfYYl ~
Checked By: Chuck Cauthe Approved By: Etienne Fonteneau Document Completion Date: 2/19/2019 Date:
Date:
Date:
z~
- z.. £Jf
- l,* 6. -z.o 11
CASE N-532-5 FORM OAR-1 OWNER'S ACTIVITY REPORT Report Number Owner's Activity Report for SG Inspection Outage C1 R24 Plant Catawba Nuclear Station, 4800 Concord Road, York, SC 29745 Unit No~. --~-----Commercial service date, June 29.1985
!If epptlceble)
Refueling outage no. ~C_1_R_24~------
Current inspection interval ________________ __,_4t"'h'-----------------------
11st, 2nd, Jtd, 4th, o1her)
Current inspection period _________________ 2=n=d~-------,,-----------------
11 st, 2ntf, 3rd)
Edition and Addenda of Section XI applicable to the inspection plans 2007 Edition through 2008 Addenda Date and revision of inspection plans _____
-'B'""-1""'9""-2""0'""'1~6~R=ev~0 _,_IC'---l=S~IS=G-'-0'""'1~69~-~03~0°",0~0'--4=0~) ____________ _
Edition and Addenda of Section XI applicable to repair/replacement activities, if different than the inspection plans Same as plan Code Cases used for inspection and evaluation: ~N=-=5~32=-=5 ___________________________ _
(II eppliceble, Including casH modllled by Case N-532 and later revlalono)
CERTIFICATE OF CONFORMANCE I certify that (al the statements made in this report are correct; (bl the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI; and (c) the repair/replacement activities and evaluations supporting the completion of C1 R24 conform to the requirements of Section XI.
(refueling outage number)
Signed Dnn Mayas, Principal Nuclear Engineer CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the_
State or Province of South Carolina and employed by OneCIS Insurance Company of Lynn, MA have inspected the items described in this Owner's Activity Report, and state that, to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair/replacement activities and evaluation described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Dustin Mallet
--?
Commissions 15196,SC#363,Al,IS,l,N,R, Inspector's Signature National Board, State, Province, and Endorsements Date 02/19/2019
TABLE 1 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE Examination Category and Item Number Item Description Evaluation Description Category B-Q B16.20.001 B16.20.002 B16.20.003 B16.20.004 Steam Generator Tubing in U-Tube Design No ASME Section XI Acceptance Requirement Exceeded (Reference Attached Inspection Report)
TABLE 2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Code Class Item Description Description of Work Date Completed Repair/Replacement Plan Number None None None None None
Catawba C1R24 Steam Generator Tube Inspection Report Pursuant to Catawba technical specification 5.6.8 the following information is provided:
- a. The scope of inspections performed on each SG Bobbin Inspection Full length bobbin probe inspection of 50% tubes. The 50% sample contained:
All tubes with previous indications, e.g., wear, DNT, PLP, etc.
All tubes surrounding plugged tubes one tube deep.
Periphery tubes two rows deep in the hot leg and cold leg (outer perimeter and open lane).
For tubes plugged last inspection for loose parts, bound the area two tubes deep in the area of interest.
50% of rows 5-6 full length.
Array Inspection 100% of periphery tubes (5 tubes in from periphery) with array probe from top of tubesheet to the first support in both hot leg (TEH to 01H) and cold leg (TEC to 01C).
Special interest inspections were also performed on selected indications.
Visual Inspection Previously installed plugs Bowl cladding inspection Foreign object search and retrieval (FOSAR) of the tubesheet in all 4 steam generators.
- b. Degradation mechanisms found Degradation found included wear at support structures and presumed wear from foreign objects.
- c. Non-destructive examination techniques utilized for each degradation mechanism The bobbin probe was utilized for the detection of wear at support structures and freespan locations and to size wear at support structures. The array probe was used to size the presumed foreign object wear.
- d. Location, orientation (if linear), and measured sizes (if available) of service induced indications.
There were 281 indications of fanbar (FB) wear reported. Thirty-four (34) of these indication were newly reported. The deepest of fanbar wear indication was 30% TW. The average growth rate was
-0.9 % TW/EFPY. There were five (5) indications of lattice grid (LG) wear reported. There were no newly reported lattice grid wear indications. The deepest of lattice grid wear indication was 21% TW.
The average growth rate for lattice grid wear was also negative. There were eighteen (18) indications of presumed foreign object wear with no part present reported. The deepest presumed foreign object wear was 26% TW. One of these indications was newly reported, its depth was 21% TW.
The complete listing for service induced indications is attached.
- e. Number of tubes plugged during the inspection outage for each degradation mechanism There were no tubes plugged in the 1A, 1B, 1C, or 1D SGs.
- f. Total number and percentage of tubes plugged to date, and the effective plugging percentage in each steam generator.
Steam Generator1 1A 1B 1C 1D Total Prior to C1R24 8
0 24 17 49 C1R24 0
0 0
0 0
Total 8
0 24 17 49
% Plugged/Effective Plugging % 0.12% 0.0% 0.36% 0.26% 0.18%
1= There are 6633 tubes per steam generator
- g. The results of condition monitoring, including the results of tube pulls and in-situ testing.
The cumulative SG EFPY for EOC-22(C1R22) was 17.38, EOC-23 (C1R23) was 18.73 and EOC-24 (C1R24) was 20.21.
As of EOC-24, the Catawba steam generators had operated 18.73 EFPY since the first in-service inspection after replacement. In total, the Catawba steam generators had operated 20.21 EFPY since replacement.
Condition monitoring structural and leakage integrity were met for fanbar, lattice grid and presumed foreign object wear.
An NDE maximum depth call of 49.0 %TW or less for fanbar wear is sufficient to demonstrate a minimum degraded tube burst pressure of 3P, 4050 psi, at 0.95 probability with 50% confidence. The worst case depth call for fanbar wear observed during the inspection was an NDE depth of 30%TW.
An NDE maximum depth call of 49.0 %TW or less for lattice grid wear is sufficient to demonstrate a minimum degraded tube burst pressure of 3P, 4050 psi, at 0.95 probability with 50% confidence. The worst case depth call for lattice grid wear observed during the inspection was an NDE depth of 11%TW.
An NDE maximum depth call of 51.8%TW or less for FO wear is sufficient to demonstrate a minimum degraded tube burst pressure of 3P, 4050 psi, at 0.95 probability with 50% confidence. The worst case depth call for FO wear observed during the inspection was an NDE depth of 26%TW.
During FOSAR, a total of 75 metal objects were found with 32 removed. All foreign objects that were not removed have a technical evaluation demonstrating that tube integrity will be met through the next scheduled inspection at C1R27. There was no wear was associated with any foreign object.
No degradation was detected in the plug visual or bowl cladding inspections.
No in-situ tests or tube pulls were performed.
SG - 1A Attachment 1 - Service Induced Indications Catawba 1 1EOC24 DCP 20181101 01/31/2019 16:50:54
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CRWID CEG BEGT ENDT PDIA PTYPE CAL L IDXl
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l 56 57.12 74 PCT 6 P5 FB4.86 WAR TEC TEH.560 ZBAHS 5 H 99l l l l 114 63.33 255 PCT 14 P5 FB7 1.73 WAR TEC TEH.560 ZBAHS 2 H 159l l l l 73 64.20 97 PCT 9 P5 FB6 -.64 WAR TEC TEH.560 ZBAHS 2 H 152l l l l 109 66.23 80 PCT 10 P5 FB7 -1.75 WAR TEC TEH.560 ZBAHS 2 H 193l l l l 55 70.19 44 PCT 8 P5 FB4 -.91 WAR TEC TEH.560 ZBAHS 6 H 91l l l l 61 70.25 237 PCT 11 P5 FB4.69 WAR TEC TEH.560 ZBAHS 5 H 57l l l l 83 72.28 90 PCT 12 P5 FB5 -.11 WAR TEC TEH.560 ZBAHS 2 H 24l l l l 89 72.43 267 PCT 17 P5 FB5.10 WAR TEC TEH.560 ZBAHS 2 H 21l l 89 72.45 90 PCT 17 P5 FB6 -.04 WAR TEC TEH.560 ZBAHS 2 H 21l l l l 111 74.30 62 PCT 12 P5 FB4.91 WAR TEC TEH.560 ZBAHS 14 H 39l l l l 80 75.25 59 PCT 10 P5 FB4 -1.02 WAR TEC TEH.560 ZBAHS 13 H 33l l l l 114 75.25 241 PCT 10 P5 FB5 1.67 WAR TEC TEH.560 ZBAHS 13 H 34l l l l 91 76.28 65 PCT 11 P5 FB6.97 WAR TEC TEH.560 ZBAHS 14 H 29l l 91 76.26 40 PCT 11 P5 FB7.69 WAR TEC TEH.560 ZBAHS 14 H 29l l l l 51 78.15 83 PCT 6 P5 01H -1.70 WAR TEC TEH.560 ZBAHS 13 H 64l l l l 55 78.19 66 PCT 8 P5 FB4 1.60 WAR TEC TEH.560 ZBAHS 13 H 63l l l l 89 78.26 245 PCT 10 P5 FB5 -.82 WAR TEC TEH.560 ZBAHS 13 H 15l l l l 101 78.25 78 PCT 10 P5 FB4 -1.58 WAR TEC TEH.560 ZBAHS 13 H 12l l l l 103 78.33 78 PCT 13 P5 FB5 -1.01 WAR TEC TEH.560 ZBAHS 14 H 12l l l l 92 79.27 258 PCT 12 P5 FB4 -.64 WAR TEC TEH.560 ZBAHS 11 H 258l l l l 81 80.17 254 PCT 8 P5 FB7 -.76 WAR TEC TEH.560 ZBAHS 11 H 255l l l l 89 80.27 285 PCT 12 P5 FB5 -1.06 WAR TEC TEH.560 ZBAHS 11 H 253l l l l 91 80.36 113 PCT 13 P5 FB6 1.76 WAR TEC TEH.560 ZBAHS 12 H 237l l l l 88 81.15 61 PCT 7 P5 FB5 -1.57 WAR TEC TEH.560 ZBAHS 11 H 243l l l l 90 81.13 92 PCT 5 P5 FB5 -1.56 WAR TEC TEH.560 ZBAHS 12 H 228l l l l 94 81.14 89 PCT 6 P5 FB5 1.72 WAR TEC TEH.560 ZBAHS 11 H 244l
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CRWID CEG BEGT ENDT PDIA PTYPE CAL L IDXl
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
1 ST Max
SG - 1A Attachment 1 - Service Induced Indications Catawba 1 1EOC24 DCP 20181101 01/31/2019 16:50:54
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CRWID CEG BEGT ENDT PDIA PTYPE CAL L IDXl
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l l l 49 82.21 278 PCT 9 P5 FB2.90 WAR TEC TEH.560 ZBAHS 14 H 84l l l l 77 82.26 86 PCT 10 P5 FB5 -.13 WAR TEC TEH.560 ZBAHS 12 H 226l l l l 91 82.25 90 PCT 11 P5 FB4 1.13 WAR TEC TEH.560 ZBAHS 11 H 237l l l l 99 82.22 272 PCT 10 P5 FB4 -1.19 WAR TEC TEH.560 ZBAHS 11 H 235l l l l 107 82.38 269 PCT 15 P5 FB5 -1.12 WAR TEC TEH.560 ZBAHS 11 H 233l l l l 102 83.25 77 PCT 11 P5 FB5 1.21 WAR TEC TEH.560 ZBAHS 11 H 229l l 102 83.20 254 PCT 9 P5 FB6 -1.13 WAR TEC TEH.560 ZBAHS 11 H 229l l l l 91 84.34 265 PCT 14 P5 FB4 -.86 WAR TEC TEH.560 ZBAHS 11 H 222l l l l 95 84.23 246 PCT 10 P5 FB4 1.18 WAR TEC TEH.560 ZBAHS 11 H 221l l l l 100 85.33 92 PCT 14 P5 FB4 1.40 WAR TEC TEH.560 ZBAHS 11 H 214l l l l 95 86.23 65 PCT 10 P5 FB4 -.72 WAR TEC TEH.560 ZBAHS 11 H 207l l l l 95 88.20 105 PCT 8 P5 FB4 -.98 WAR TEC TEH.560 ZBAHS 12 H 182l l l l 77 90.23 76 PCT 10 P5 FB5 -1.24 WAR TEC TEH.560 ZBAHS 11 H 187l l l l 108 93.17 248 PCT 8 P5 FB5 1.94 WAR TEC TEH.560 ZBAHS 11 H 164l l l l 96 109.19 93 PCT 8 P5 FB5 1.95 WAR TEC TEH.560 ZBAHS 12 H 65l l l l 69 112 1.13 60 PCT 21 207 07H.53.22.22 07H 07H.560 ZYAX2 27 H 366l
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CRWID CEG BEGT ENDT PDIA PTYPE CAL L IDXl
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
Tubes: 39 Records: 42 2 ST Max
SG - 1B Attachment 1 - Service Induced Indications Catawba 1 1EOC24 DCP 20181101 01/31/2019 16:50:54
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CRWID CEG BEGT ENDT PDIA PTYPE CAL L IDXl
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l 10 11.29 121 PCT 11 207 TSH.22.17.20 01H TEH.560 ZYAX2 30 H 96l l l l 73 18.39 83 PCT 17 74 TSH.19.20.23 01H TEH.560 ZYAX2 29 H 184l l l l 75 18.54 122 PCT 15 207 TSH.26.15.20 01H TEH.560 ZYAX2 30 H 182l l l l 72 19.38 100 PCT 12 207 TSH.07.17.14 01H TEH.560 ZYAX2 30 H 188l l 72 19.38 128 PCT 12 207 TSH.20.19.20 01H TEH.560 ZYAX2 30 H 188l l l l 81 60.34 63 PCT 12 P5 FB5 -.81 WAR TEC TEH.560 ZBAHS 2 H 194l l l l 89 60.30 250 PCT 11 P5 FB5 -.91 WAR TEC TEH.560 ZBAHS 2 H 192l l 89 60.20 81 PCT 8 P5 FB6 -1.19 WAR TEC TEH.560 ZBAHS 2 H 192l l l l 101 60.31 243 PCT 12 P5 FB5.97 WAR TEC TEH.560 ZBAHS 2 H 189l l l l 99 62.32 248 PCT 12 P5 FB5 1.09 WAR TEC TEH.560 ZBAHS 2 H 184l l l l 80 63.16 116 PCT 7 P5 FB5 -.56 WAR TEC TEH.560 ZBAHS 2 H 170l l l l 100 63.32 265 PCT 12 P5 FB6 -.82 WAR TEC TEH.560 ZBAHS 2 H 177l l 100 63.25 272 PCT 10 P5 FB6 1.39 WAR TEC TEH.560 ZBAHS 2 H 177l l l l 95 64.25 260 PCT 7 P5 FB5 -.81 WAR TEC TEH.560 ZBAHS 1 H 154l l l l 100 67.13 94 PCT 5 P5 FB4 -.92 WAR TEC TEH.560 ZBAHS 2 H 134l l l l 69 70.30 112 PCT 13 P5 FB4.88 WAR TEC TEH.560 ZBAHS 7 H 20l l l l 91 70.19 87 PCT 8 P5 FB4 1.40 WAR TEC TEH.560 ZBAHS 2 H 110l l 91 70.30 77 PCT 11 P5 FB5 1.09 WAR TEC TEH.560 ZBAHS 2 H 110l l 91 70.54 79 PCT 18 P5 FB6.05 WAR TEC TEH.560 ZBAHS 2 H 110l l l l 97 70.78 278 PCT 20 P5 FB5 -1.15 WAR TEC TEH.560 ZBAHS 1 H 106l l 97 70.25 97 PCT 7 P5 FB5 1.24 WAR TEC TEH.560 ZBAHS 1 H 106l l 97 70.50 99 PCT 14 P5 FB6 -1.35 WAR TEC TEH.560 ZBAHS 1 H 106l l 97 70.22 88 PCT 7 P5 FB6 1.12 WAR TEC TEH.560 ZBAHS 1 H 106l l 97 70.18 292 PCT 6 P5 FB8 1.37 WAR TEC TEH.560 ZBAHS 1 H 106l l l l 103 70.31 71 PCT 12 P5 FB4 -1.09 WAR TEC TEH.560 ZBAHS 2 H 107l l l l 117 70.23 270 PCT 7 P5 FB5 -.73 WAR TEC TEH.560 ZBAHS 1 H 101l l 117 70.41 96 PCT 12 P5 FB5 1.04 WAR TEC TEH.560 ZBAHS 1 H 101l l 117 70.42 92 PCT 12 P5 FB6 1.00 WAR TEC TEH.560 ZBAHS 1 H 101l l l l 66 73.30 109 PCT 11 P5 FB5.86 WAR TEC TEH.560 ZBAHS 11 H 84l l l l 82 75.23 100 PCT 10 P5 FB4 -1.17 WAR TEC TEH.560 ZBAHS 7 H 115l l l
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CRWID CEG BEGT ENDT PDIA PTYPE CAL L IDXl
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
1 ST Max
SG - 1B Attachment 1 - Service Induced Indications Catawba 1 1EOC24 DCP 20181101 01/31/2019 16:50:54
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CRWID CEG BEGT ENDT PDIA PTYPE CAL L IDXl
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l 96 75.24 91 PCT 9 P5 FB6 -.67 WAR TEC TEH.560 ZBAHS 8 H 113l l l l 95 76.40 89 PCT 14 P5 FB4 -.87 WAR TEC TEH.560 ZBAHS 8 H 121l l 95 76.27 103 PCT 10 P5 FB5 -.97 WAR TEC TEH.560 ZBAHS 8 H 121l l 95 76.34 106 PCT 12 P5 FB6 -.80 WAR TEC TEH.560 ZBAHS 8 H 121l l l l 65 80.49 106 PCT 19 P5 FB4 1.02 WAR TEC TEH.560 ZBAHS 12 H 153l l l l 74 83.22 104 PCT 10 P5 FB4 1.35 WAR TEC TEH.560 ZBAHS 7 H 154l l l l 82 83.22 98 PCT 10 P5 FB4 1.22 WAR TEC TEH.560 ZBAHS 7 H 156l l l l 86 83.24 98 PCT 10 P5 FB4 1.20 WAR TEC TEH.560 ZBAHS 7 H 157l l 86 83.38 283 PCT 15 P5 FB5 1.47 WAR TEC TEH.560 ZBAHS 7 H 157l l l l 98 83.38 88 PCT 15 P5 FB5.98 WAR TEC TEH.560 ZBAHS 7 H 160l l l l 46 89.18 97 PCT 9 P5 FB5 1.38 WAR TEC TEH.560 ZBAHS 13 H 25l l l l 84 97.36 236 PCT 14 P5 FB3.96 WAR TEC TEH.560 ZBAHS 10 H 57l l l l 93 100.13 252 PCT 6 P5 07H.56 WAR TEC TEH.560 ZBAHS 10 H 94l l l l 106 103.25 73 PCT 10 207 TSH 6.82.15.14 01H TEH.560 ZYAX2 30 H 25l
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CRWID CEG BEGT ENDT PDIA PTYPE CAL L IDXl
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
Tubes: 30 Records: 44 2 ST Max
SG - 1C Attachment 1 - Service Induced Indications Catawba 1 1EOC24 DCP 20181101 01/31/2019 16:50:54
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CRWID CEG BEGT ENDT PDIA PTYPE CAL L IDXl
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l 46 7.26 100 PCT 10 207 TSH 9.31.13.14 01H TEH.560 ZYAX2 1 H 147l l l l 32 31.10 99 PCT 4 P5 02H.56 WAR TEC TEH.560 ZBAHS 10 H 57l l l l 104 37.17 84 PCT 10 203 TSH 11.90.22.20 01H TEH.560 ZYAX2 1 H 290l l l l 63 44.18 281 PCT 8 P5 FB4 -1.92 WAR TEC TEH.560 ZBAHS 8 H 259l l l l 80 51.20 289 PCT 8 P5 FB3 -1.56 WAR TEC TEH.560 ZBAHS 6 H 173l l l l 79 52.46 86 PCT 20 P5 FB3 -2.00 WAR TEC TEH.560 ZBAHS 5 H 168l l l l 70 55.25 84 PCT 10 P5 FB5 -1.29 WAR TEC TEH.560 ZBAHS 6 H 148l l l l 76 59.25 63 PCT 13 P5 FB6 -1.72 WAR TEC TEH.560 ZBAHS 5 H 106l l l l 80 59.23 92 PCT 12 P5 FB5 1.85 WAR TEC TEH.560 ZBAHS 5 H 107l l l l 86 59.24 95 PCT 10 P5 FB4 1.61 WAR TEC TEH.560 ZBAHS 6 H 116l l l l 75 60.42 281 PCT 15 P5 FB4 -1.20 WAR TEC TEH.560 ZBAHS 6 H 110l l 75 60.23 119 PCT 9 P5 FB6 -1.09 WAR TEC TEH.560 ZBAHS 6 H 110l l l l 79 60.25 108 PCT 10 P5 FB4 -1.26 WAR TEC TEH.560 ZBAHS 6 H 109l l l l 81 60.12 83 PCT 7 P5 FB6 -.79 WAR TEC TEH.560 ZBAHS 5 H 102l l l l 66 61.32 82 PCT 13 P5 FB5 1.75 WAR TEC TEH.560 ZBAHS 8 H 140l l l l 72 61.40 111 PCT 15 P5 FB5 1.27 WAR TEC TEH.560 ZBAHS 6 H 95l l l l 76 61.39 89 PCT 14 P5 FB5 1.37 WAR TEC TEH.560 ZBAHS 6 H 96l l l l 80 61.29 94 PCT 11 P5 FB4 1.24 WAR TEC TEH.560 ZBAHS 6 H 97l l 80 61.39 91 PCT 14 P5 FB7 1.15 WAR TEC TEH.560 ZBAHS 6 H 97l l l l 86 61.30 275 PCT 11 P5 FB4 -1.10 WAR TEC TEH.560 ZBAHS 6 H 98l l 86 61.49 105 PCT 17 P5 FB5 -1.34 WAR TEC TEH.560 ZBAHS 6 H 98l l l l 73 62.18 113 PCT 10 P5 FB6 -.96 WAR TEC TEH.560 ZBAHS 5 H 91l l l l 75 62.56 107 PCT 19 P5 FB4 -1.15 WAR TEC TEH.560 ZBAHS 6 H 93l l l l 79 62.69 279 PCT 22 P5 FB4 -1.28 WAR TEC TEH.560 ZBAHS 6 H 92l l 79 62.23 99 PCT 9 P5 FB5 1.34 WAR TEC TEH.560 ZBAHS 6 H 92l l l l 85 62.17 82 PCT 9 P5 FB4 -.54 WAR TEC TEH.560 ZBAHS 5 H 88l l 85 62.17 81 PCT 9 P5 FB5 -.36 WAR TEC TEH.560 ZBAHS 5 H 88l l l
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CRWID CEG BEGT ENDT PDIA PTYPE CAL L IDXl
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
1 ST Max
SG - 1C Attachment 1 - Service Induced Indications Catawba 1 1EOC24 DCP 20181101 01/31/2019 16:50:54
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CRWID CEG BEGT ENDT PDIA PTYPE CAL L IDXl
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l 91 62.29 100 PCT 11 P5 FB4 1.20 WAR TEC TEH.560 ZBAHS 6 H 89l l 91 62.32 107 PCT 12 P5 FB5 -1.14 WAR TEC TEH.560 ZBAHS 6 H 89l l 91 62.40 103 PCT 15 P5 FB5 1.25 WAR TEC TEH.560 ZBAHS 6 H 89l l l l 109 62.16 115 PCT 9 P5 FB4 -1.11 WAR TEC TEH.560 ZBAHS 5 H 82l l l l 94 63.25 84 PCT 10 P5 FB6 -1.11 WAR TEC TEH.560 ZBAHS 6 H 80l l l l 51 64.19 104 PCT 9 P5 FB4 1.39 WAR TEC TEH.560 ZBAHS 7 H 132l l l l 85 64.21 87 PCT 11 P5 FB5 -.48 WAR TEC TEH.560 ZBAHS 5 H 77l l l l 74 65.28 285 PCT 11 P5 FB4 1.12 WAR TEC TEH.560 ZBAHS 6 H 68l l 74 65.39 268 PCT 14 P5 FB5 1.35 WAR TEC TEH.560 ZBAHS 6 H 68l l 74 65.25 92 PCT 10 P5 FB6 -1.62 WAR TEC TEH.560 ZBAHS 6 H 68l l l l 82 65.27 269 PCT 10 P5 FB5 1.71 WAR TEC TEH.560 ZBAHS 6 H 70l l l l 3 66.18 81 PCT 9 207 TSC 1.75.17.20 01C TEC.560 ZYAX2 5 C 24l l l l 79 66.10 94 PCT 6 P5 FB8.73 WAR TEC TEH.560 ZBAHS 5 H 62l l l l 97 66.54 100 PCT 18 P5 FB5 1.21 WAR TEC TEH.560 ZBAHS 6 H 66l l l l 99 66.26 106 PCT 13 P5 FB5.97 WAR TEC TEH.560 ZBAHS 5 H 61l l 99 66.21 58 PCT 11 P5 FB6.75 WAR TEC TEH.560 ZBAHS 5 H 61l l 99 66.14 82 PCT 8 P5 FB7.63 WAR TEC TEH.560 ZBAHS 5 H 61l l l l 2 67.48 271 PCT 14 174 TSC 1.48.26.20 01C TEC.560 ZYAX2 6 C 28l l l l 98 67.27 104 PCT 10 P5 FB4 1.38 WAR TEC TEH.560 ZBAHS 6 H 62l l 98 67.33 103 PCT 12 P5 FB5 1.26 WAR TEC TEH.560 ZBAHS 6 H 62l l 98 67.28 91 PCT 11 P5 FB7 -1.27 WAR TEC TEH.560 ZBAHS 6 H 62l l 98 67.51 283 PCT 18 P5 FB7 1.24 WAR TEC TEH.560 ZBAHS 6 H 62l l l l 108 67.42 103 PCT 15 P5 FB7 1.23 WAR TEC TEH.560 ZBAHS 6 H 63l l l l 77 68.19 81 PCT 10 P5 FB6 -.61 WAR TEC TEH.560 ZBAHS 5 H 57l l l l 98 69.31 105 PCT 12 P5 FB5 1.32 WAR TEC TEH.560 ZBAHS 6 H 48l l l l 102 69.26 113 PCT 10 P5 FB5 1.20 WAR TEC TEH.560 ZBAHS 6 H 49l l 102 69.74 96 PCT 23 P5 FB6 1.29 WAR TEC TEH.560 ZBAHS 6 H 49l l 102 69.25 73 PCT 10 P5 FB7 1.28 WAR TEC TEH.560 ZBAHS 6 H 49l l l l 106 69.30 95 PCT 11 P5 FB6 2.14 WAR TEC TEH.560 ZBAHS 6 H 50l l l l 114 69.29 106 PCT 11 P5 FB6 1.17 WAR TEC TEH.560 ZBAHS 6 H 51l l l
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CRWID CEG BEGT ENDT PDIA PTYPE CAL L IDXl
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
2 ST Max
SG - 1C Attachment 1 - Service Induced Indications Catawba 1 1EOC24 DCP 20181101 01/31/2019 16:50:54
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CRWID CEG BEGT ENDT PDIA PTYPE CAL L IDXl
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l 1 70.29 258 PCT 14 134 TSC 1.22.24.14 01C TEC.560 ZYAX2 6 C 27l l l l 93 70.24 283 PCT 9 P5 FB4 -1.16 WAR TEC TEH.560 ZBAHS 6 H 41l l 93 70.21 93 PCT 8 P5 FB5 -1.13 WAR TEC TEH.560 ZBAHS 6 H 41l l 93 70.28 100 PCT 11 P5 FB5 1.14 WAR TEC TEH.560 ZBAHS 6 H 41l l 93 70.22 109 PCT 9 P5 FB6 1.22 WAR TEC TEH.560 ZBAHS 6 H 41l l l l 95 70.18 70 PCT 10 P5 FB4 -1.11 WAR TEC TEH.560 ZBAHS 5 H 39l l 95 70.16 59 PCT 9 P5 FB5 -1.11 WAR TEC TEH.560 ZBAHS 5 H 39l l 95 70.27 77 PCT 14 P5 FB6.69 WAR TEC TEH.560 ZBAHS 5 H 39l l l l 89 72.32 88 PCT 12 P5 FB6 -.13 WAR TEC TEH.560 ZBAHS 6 H 14l l l l 91 72.22 81 PCT 11 P5 FB6.07 WAR TEC TEH.560 ZBAHS 5 H 13l l l l 95 72.24 80 PCT 12 P5 FB4.20 WAR TEC TEH.560 ZBAHS 5 H 12l l 95 72.20 90 PCT 10 P5 FB5 -.16 WAR TEC TEH.560 ZBAHS 5 H 12l l 95 72.28 90 PCT 14 P5 FB6 -.16 WAR TEC TEH.560 ZBAHS 5 H 12l l l l 98 73.28 106 PCT 11 P5 FB4 -.97 WAR TEC TEH.560 ZBAHS 14 H 267l l 98 73.33 111 PCT 13 P5 FB5 -1.07 WAR TEC TEH.560 ZBAHS 14 H 267l l l l 88 75.22 95 PCT 9 P5 FB5 -1.19 WAR TEC TEH.560 ZBAHS 14 H 245l l l l 96 75.19 92 PCT 8 P5 FB5 -1.27 WAR TEC TEH.560 ZBAHS 14 H 247l l l l 104 75.13 97 PCT 6 P5 FB4 -.59 WAR TEC TEH.560 ZBAHS 14 H 249l l l l 110 75.19 71 PCT 10 P5 FB6.85 WAR TEC TEH.560 ZBAHS 13 H 237l l l l 75 76.53 99 PCT 19 P5 FB5 2.22 WAR TEC TEH.560 ZBAHS 14 H 240l l l l 83 76.97 276 PCT 29 P5 FB5 -.15 WAR TEC TEH.560 ZBAHS 14 H 238l l 83 76.38 84 PCT 15 P5 FB6 -.68 WAR TEC TEH.560 ZBAHS 14 H 238l l l l 85 76.84 103 PCT 30 P5 FB5 -.53 WAR TEC TEH.560 ZBAHS 13 H 226l l 85 76.26 270 PCT 13 P5 FB6 -.37 WAR TEC TEH.560 ZBAHS 13 H 226l l l l 97 76.27 116 PCT 11 P5 FB4 1.42 WAR TEC TEH.560 ZBAHS 14 H 235l l l l 86 77.31 262 PCT 15 P5 FB8 -.10 WAR TEC TEH.560 ZBAHS 13 H 216l l l l 98 77.50 98 PCT 21 P5 FB5 -1.48 WAR TEC TEH.560 ZBAHS 13 H 219l l l l 102 77.25 110 PCT 12 P5 FB3 1.47 WAR TEC TEH.560 ZBAHS 13 H 220l l 102 77.55 95 PCT 23 P5 FB4 -.94 WAR TEC TEH.560 ZBAHS 13 H 220l l 102 77.36 280 PCT 17 P5 FB5 -1.57 WAR TEC TEH.560 ZBAHS 13 H 220l l 102 77.41 109 PCT 19 P5 FB7 -1.39 WAR TEC TEH.560 ZBAHS 13 H 220l l l
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CRWID CEG BEGT ENDT PDIA PTYPE CAL L IDXl
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
3 ST Max
SG - 1C Attachment 1 - Service Induced Indications Catawba 1 1EOC24 DCP 20181101 01/31/2019 16:50:54
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CRWID CEG BEGT ENDT PDIA PTYPE CAL L IDXl
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l 69 78.21 240 PCT 9 P5 FB5 -.73 WAR TEC TEH.560 ZBAHS 18 H 153l l l l 97 78.33 112 PCT 16 P5 FB4 1.25 WAR TEC TEH.560 ZBAHS 13 H 211l l 97 78.30 257 PCT 15 P5 FB5 -1.01 WAR TEC TEH.560 ZBAHS 13 H 211l l 97 78.22 257 PCT 11 P5 FB5 1.25 WAR TEC TEH.560 ZBAHS 13 H 211l l 97 78.71 94 PCT 27 P5 FB6 -.96 WAR TEC TEH.560 ZBAHS 13 H 211l l l l 99 78.41 272 PCT 16 P5 FB4 1.33 WAR TEC TEH.560 ZBAHS 14 H 219l l l l 101 78.25 82 PCT 12 P5 FB4 -.93 WAR TEC TEH.560 ZBAHS 13 H 210l l 101 78.29 93 PCT 14 P5 FB4 1.34 WAR TEC TEH.560 ZBAHS 13 H 210l l 101 78.33 103 PCT 16 P5 FB5 -.85 WAR TEC TEH.560 ZBAHS 13 H 210l l 101 78.19 93 PCT 10 P5 FB6 -1.38 WAR TEC TEH.560 ZBAHS 13 H 210l l l l 103 78.41 98 PCT 15 P5 FB6 -1.23 WAR TEC TEH.560 ZBAHS 14 H 218l l l l 69 80.33 248 PCT 13 P5 FB5 -.09 WAR TEC TEH.560 ZBAHS 18 H 139l l l l 79 80.23 125 PCT 10 P5 FB4.92 WAR TEC TEH.560 ZBAHS 14 H 201l l l l 101 80.20 74 PCT 10 P5 FB4 -1.20 WAR TEC TEH.560 ZBAHS 13 H 189l l l l 80 81.30 279 PCT 15 P5 FB4 -1.15 WAR TEC TEH.560 ZBAHS 13 H 181l l l l 96 81.20 96 PCT 10 P5 FB5 -1.53 WAR TEC TEH.560 ZBAHS 13 H 182l l l l 100 81.19 259 PCT 10 P5 FB5 1.64 WAR TEC TEH.560 ZBAHS 13 H 183l l l l 102 83.27 89 PCT 13 P5 FB5 -1.63 WAR TEC TEH.560 ZBAHS 13 H 176l l l l 83 84.34 93 PCT 13 P5 FB5 -.26 WAR TEC TEH.560 ZBAHS 14 H 175l l l l 98 85.24 264 PCT 12 P5 FB3.85 WAR TEC TEH.560 ZBAHS 13 H 162l l 98 85.16 73 PCT 9 P5 FB4 -.87 WAR TEC TEH.560 ZBAHS 13 H 162l l 98 85.30 79 PCT 15 P5 FB4 1.73 WAR TEC TEH.560 ZBAHS 13 H 162l l 98 85.28 100 PCT 14 P5 FB5 -1.19 WAR TEC TEH.560 ZBAHS 13 H 162l l 98 85.27 84 PCT 13 P5 FB5 1.24 WAR TEC TEH.560 ZBAHS 13 H 162l l 98 85.20 90 PCT 10 P5 FB6 -1.66 WAR TEC TEH.560 ZBAHS 13 H 162l l l l 63 86.18 64 PCT 10 P5 FB4 -.80 WAR TEC TEH.560 ZBAHS 17 H 92l l l l 79 86.25 76 PCT 13 P5 FB5 -.60 WAR TEC TEH.560 ZBAHS 13 H 152l l 79 86.21 83 PCT 11 P5 FB6 -.33 WAR TEC TEH.560 ZBAHS 13 H 152l l l l 97 86.36 271 PCT 14 P5 FB5 -.98 WAR TEC TEH.560 ZBAHS 14 H 155l l 97 86.90 280 PCT 27 P5 FB6 -.73 WAR TEC TEH.560 ZBAHS 14 H 155l l l l 101 86.20 293 PCT 8 P5 FB5 -.77 WAR TEC TEH.560 ZBAHS 14 H 154l l 101 86.18 104 PCT 8 P5 FB6 -.82 WAR TEC TEH.560 ZBAHS 14 H 154l
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CRWID CEG BEGT ENDT PDIA PTYPE CAL L IDXl
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
4 ST Max
SG - 1C Attachment 1 - Service Induced Indications Catawba 1 1EOC24 DCP 20181101 01/31/2019 16:50:54
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CRWID CEG BEGT ENDT PDIA PTYPE CAL L IDXl
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l l l 103 86.26 263 PCT 13 P5 FB6 -1.02 WAR TEC TEH.560 ZBAHS 13 H 146l l l l 105 86.29 264 PCT 12 P5 FB5 -.69 WAR TEC TEH.560 ZBAHS 14 H 153l l l l 113 86.18 104 PCT 8 P5 FB5 -.73 WAR TEC TEH.560 ZBAHS 14 H 151l l l l 74 87.36 88 PCT 17 P5 FB4 -1.42 WAR TEC TEH.560 ZBAHS 13 H 138l l l l 90 87.34 281 PCT 16 P5 FB5 1.35 WAR TEC TEH.560 ZBAHS 13 H 139l l l l 92 87.31 88 PCT 12 P5 FB5 -1.20 WAR TEC TEH.560 ZBAHS 14 H 146l l l l 96 87.20 115 PCT 10 P5 FB4 1.66 WAR TEC TEH.560 ZBAHS 13 H 140l l 96 87.27 275 PCT 14 P5 FB5 1.71 WAR TEC TEH.560 ZBAHS 13 H 140l l 96 87.13 96 PCT 7 P5 FB6 -1.16 WAR TEC TEH.560 ZBAHS 13 H 140l l l l 98 87.25 94 PCT 10 P5 FB5 -1.34 WAR TEC TEH.560 ZBAHS 14 H 147l l 98 87.26 98 PCT 11 P5 FB6 -1.20 WAR TEC TEH.560 ZBAHS 14 H 147l l l l 100 87.33 89 PCT 16 P5 FB4 1.43 WAR TEC TEH.560 ZBAHS 13 H 141l l 100 87.18 86 PCT 9 P5 FB5 -1.49 WAR TEC TEH.560 ZBAHS 13 H 141l l l l 102 87.35 89 PCT 14 P5 FB5 -.82 WAR TEC TEH.560 ZBAHS 14 H 148l l l l 63 88.22 56 PCT 9 P5 FB4 -1.07 WAR TEC TEH.560 ZBAHS 18 H 83l l l l 77 88.22 75 PCT 11 P5 FB5 -.42 WAR TEC TEH.560 ZBAHS 13 H 137l l l l 79 88.18 111 PCT 8 P5 FB5.02 WAR TEC TEH.560 ZBAHS 14 H 145l l l l 105 88.56 282 PCT 20 P5 FB5 -.61 WAR TEC TEH.560 ZBAHS 14 H 143l l l l 84 103.10 110 PCT 6 P5 05H.49 WAR TEC TEH.560 ZBAHS 13 H 43l l l l 92 115.23 76 PCT 10 207 TSC 17.45.19.27 01C TEC.560 ZYAX2 1 C 214l l l l 93 116.20 80 PCT 11 110 TSC 16.27.17.27 01C TEC.560 ZYAX2 2 C 250l
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CRWID CEG BEGT ENDT PDIA PTYPE CAL L IDXl
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
Tubes: 94 Records: 141 5 ST Max
SG - 1D Attachment 1 - Service Induced Indications Catawba 1 1EOC24 DCP 20181101 01/31/2019 16:50:54
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CRWID CEG BEGT ENDT PDIA PTYPE CAL L IDXl
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l 97 34.32 70 PCT 11 30 TSC.43.17.20 01C TEC.560 ZYAX2 1 C 269l l l l 99 34 1.72 87 PCT 26 207 TSC.23.23.24 01C TEC.560 ZYAX2 2 C 299l l l l 109 54.19 28 PCT 9 207 05H 34.46.26.20 06H 05H.560 ZYAX2 36 H 12l l l l 72 59.21 80 PCT 12 P5 FB5.48 WAR TEC TEH.560 ZBAHS 8 H 197l l l l 94 61.21 68 PCT 12 P5 FB5.57 WAR TEC TEH.560 ZBAHS 8 H 211l l 94 61.40 275 PCT 20 P5 FB6 1.07 WAR TEC TEH.560 ZBAHS 8 H 211l l l l 114 61.27 261 PCT 14 P5 FB4 -.49 WAR TEC TEH.560 ZBAHS 8 H 212l l l l 89 62.19 70 PCT 10 P5 FB5.36 WAR TEC TEH.560 ZBAHS 9 H 231l l l l 91 62.27 256 PCT 15 P5 FB5 -.66 WAR TEC TEH.560 ZBAHS 8 H 219l l l l 93 62.45 89 PCT 20 P5 FB5 -.77 WAR TEC TEH.560 ZBAHS 9 H 230l l 93 62.08 52 PCT 5 P5 FB6 -.75 WAR TEC TEH.560 ZBAHS 9 H 230l l 93 62.21 74 PCT 11 P5 FB7 -.48 WAR TEC TEH.560 ZBAHS 9 H 230l l l l 95 62.19 260 PCT 11 P5 FB5 -.61 WAR TEC TEH.560 ZBAHS 8 H 218l l l l 80 63.26 89 PCT 14 P5 FB6 -1.35 WAR TEC TEH.560 ZBAHS 8 H 225l l l l 95 64.17 260 PCT 10 P5 FB5 1.67 WAR TEC TEH.560 ZBAHS 8 H 233l l l l 97 64.10 83 PCT 6 P5 FB5 -1.38 WAR TEC TEH.560 ZBAHS 9 H 243l l l l 99 64.18 274 PCT 11 P5 FB5 1.64 WAR TEC TEH.560 ZBAHS 8 H 232l l l l 113 64.15 68 PCT 9 P5 FB5 -1.52 WAR TEC TEH.560 ZBAHS 8 H 229l l l l 100 65.08 245 PCT 5 P5 FB4 1.48 WAR TEC TEH.560 ZBAHS 8 H 240l l l l 110 65.21 265 PCT 12 P5 FB3 -1.01 WAR TEC TEH.560 ZBAHS 8 H 241l l 110 65.19 87 PCT 11 P5 FB4 -1.00 WAR TEC TEH.560 ZBAHS 8 H 241l l 110 65.31 254 PCT 16 P5 FB5 -1.58 WAR TEC TEH.560 ZBAHS 8 H 241l l l l 57 66.49 95 PCT 22 P5 FB5 -1.19 WAR TEC TEH.560 ZBAHS 10 H 95l l l l 71 66.10 69 PCT 6 P5 FB5 1.81 WAR TEC TEH.560 ZBAHS 9 H 264l l l l 77 66.22 73 PCT 12 P5 FB5 1.14 WAR TEC TEH.560 ZBAHS 8 H 253l l l l 79 66.10 60 PCT 6 P5 FB5.30 WAR TEC TEH.560 ZBAHS 9 H 262l l l l 94 67.20 85 PCT 11 P5 FB4 -.74 WAR TEC TEH.560 ZBAHS 8 H 255l l 94 67.17 252 PCT 10 P5 FB6 -1.27 WAR TEC TEH.560 ZBAHS 8 H 255l
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CRWID CEG BEGT ENDT PDIA PTYPE CAL L IDXl
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
1 ST Max
SG - 1D Attachment 1 - Service Induced Indications Catawba 1 1EOC24 DCP 20181101 01/31/2019 16:50:54
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CRWID CEG BEGT ENDT PDIA PTYPE CAL L IDXl
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l l l 79 68.21 67 PCT 11 P5 FB5 -.83 WAR TEC TEH.560 ZBAHS 11 H 18l l l l 81 68.21 88 PCT 11 P5 FB4 1.64 WAR TEC TEH.560 ZBAHS 10 H 14l l 81 68.28 103 PCT 14 P5 FB6 -.34 WAR TEC TEH.560 ZBAHS 10 H 14l l l l 95 68.23 80 PCT 12 P5 FB3 -.66 WAR TEC TEH.560 ZBAHS 11 H 12l l 95 68.37 100 PCT 17 P5 FB5 -.64 WAR TEC TEH.560 ZBAHS 11 H 12l l 95 68.35 96 PCT 17 P5 FB7 -.61 WAR TEC TEH.560 ZBAHS 11 H 12l l l l 97 68.73 103 PCT 28 P5 FB5 -.67 WAR TEC TEH.560 ZBAHS 10 H 10l l 97 68.18 288 PCT 10 P5 FB6 -.45 WAR TEC TEH.560 ZBAHS 10 H 10l l l l 99 68.19 99 PCT 10 P5 FB5 1.25 WAR TEC TEH.560 ZBAHS 11 H 11l l l l 80 69.12 109 PCT 7 P5 FB4 1.38 WAR TEC TEH.560 ZBAHS 10 H 19l l l l 90 69.30 106 PCT 15 P5 FB4.78 WAR TEC TEH.560 ZBAHS 10 H 20l l l l 92 69.23 81 PCT 12 P5 FB4.91 WAR TEC TEH.560 ZBAHS 11 H 21l l l l 100 69.37 104 PCT 18 P5 FB5 1.00 WAR TEC TEH.560 ZBAHS 10 H 21l l 100 69.50 100 PCT 22 P5 FB6 1.06 WAR TEC TEH.560 ZBAHS 10 H 21l l l l 102 69.18 91 PCT 10 P5 FB4 1.00 WAR TEC TEH.560 ZBAHS 11 H 22l l l l 114 69.14 54 PCT 8 P5 FB4 -1.09 WAR TEC TEH.560 ZBAHS 10 H 22l l 114 69.16 68 PCT 9 P5 FB4 1.59 WAR TEC TEH.560 ZBAHS 10 H 22l l 114 69.17 75 PCT 9 P5 FB5.92 WAR TEC TEH.560 ZBAHS 10 H 22l l l l 77 70.19 292 PCT 10 P5 FB5 1.63 WAR TEC TEH.560 ZBAHS 10 H 33l l l l 93 70.47 94 PCT 21 P5 FB5 -1.16 WAR TEC TEH.560 ZBAHS 10 H 29l l 93 70.28 87 PCT 15 P5 FB6 -1.17 WAR TEC TEH.560 ZBAHS 10 H 29l l l l 88 71.18 297 PCT 10 P5 FB5 -.81 WAR TEC TEH.560 ZBAHS 10 H 35l l l l 108 71.25 91 PCT 13 P5 FB5 -.40 WAR TEC TEH.560 ZBAHS 10 H 36l l l l 93 72.15 279 PCT 9 P5 FB4 -.38 WAR TEC TEH.560 ZBAHS 10 H 44l l l l 105 72.17 84 PCT 10 P5 FB6 -.46 WAR TEC TEH.560 ZBAHS 10 H 41l l l l 80 73.25 110 PCT 14 P5 FB4 1.43 WAR TEC TEH.560 ZBAHS 14 H 91l l 80 73.43 93 PCT 21 P5 FB5 1.55 WAR TEC TEH.560 ZBAHS 14 H 91l l l l 86 73.30 105 PCT 16 P5 FB4 1.30 WAR TEC TEH.560 ZBAHS 14 H 92l l 86 73.48 100 PCT 22 P5 FB5 1.75 WAR TEC TEH.560 ZBAHS 14 H 92l l 86 73.37 98 PCT 19 P5 FB6 -1.30 WAR TEC TEH.560 ZBAHS 14 H 92l
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CRWID CEG BEGT ENDT PDIA PTYPE CAL L IDXl
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
2 ST Max
SG - 1D Attachment 1 - Service Induced Indications Catawba 1 1EOC24 DCP 20181101 01/31/2019 16:50:54
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CRWID CEG BEGT ENDT PDIA PTYPE CAL L IDXl
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l l l 88 73.34 100 PCT 16 P5 FB5.92 WAR TEC TEH.560 ZBAHS 15 H 85l l l l 92 73.32 106 PCT 17 P5 FB5 1.00 WAR TEC TEH.560 ZBAHS 14 H 93l l l l 108 73.17 98 PCT 10 P5 FB4 1.59 WAR TEC TEH.560 ZBAHS 14 H 94l l l l 65 74.21 68 PCT 11 P5 FB5.97 WAR TEC TEH.560 ZBAHS 20 H 166l l l l 67 74.22 61 PCT 11 P5 FB5 1.32 WAR TEC TEH.560 ZBAHS 21 H 151l l l l 69 74.35 69 PCT 17 P5 FB5.87 WAR TEC TEH.560 ZBAHS 20 H 165l l l l 36 75.20 280 PCT 11 P5 03H -1.54 WAR TEC TEH.560 ZBAHS 20 H 207l l l l 114 75.16 94 PCT 9 P5 FB6 -.81 WAR TEC TEH.560 ZBAHS 14 H 107l l l l 53 76.71 89 PCT 28 P5 FB4 1.59 WAR TEC TEH.560 ZBAHS 20 H 189l l l l 63 78.13 221 PCT 7 P5 FB5 -1.16 WAR TEC TEH.560 ZBAHS 21 H 182l l l l 77 78.14 86 PCT 8 P5 FB5 1.98 WAR TEC TEH.560 ZBAHS 14 H 133l l l l 52 79.25 265 PCT 13 P5 FB5 -.77 WAR TEC TEH.560 ZBAHS 20 H 209l l l l 101 80.22 90 PCT 12 P5 FB6 -.98 WAR TEC TEH.560 ZBAHS 14 H 141l l l l 85 84.23 254 PCT 13 P5 FB5 -1.06 WAR TEC TEH.560 ZBAHS 14 H 175l l l l 66 85.19 108 PCT 12 P5 FB4 1.40 WAR TEC TEH.560 ZBAHS 22 H 21l l l l 109 88.11 69 PCT 6 P5 FB5 1.28 WAR TEC TEH.560 ZBAHS 16 H 16l l l l 63 90.42 107 PCT 13 207 04H 29.44.30.20 05H 04H.560 ZYAX2 36 H 13l l l l 52 91.18 263 PCT 10 P5 FB4 -1.00 WAR TEC TEH.560 ZBAHS 20 H 163l l l l 62 95.23 81 PCT 12 P5 FB4 -1.11 WAR TEC TEH.560 ZBAHS 20 H 123l
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
l ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CRWID CEG BEGT ENDT PDIA PTYPE CAL L IDXl
+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+-------+----+----+----+------+------+------+--+-----+
Tubes: 60 Records: 77 3 ST Max