ML19058A467

From kanterella
Jump to navigation Jump to search

Summary of Meeting with Northern States Power Company, Doing Business as Xcel Energy, Related to the Amendment Request to Modify Renewed Facility Operating License Paragraph 2.C(4)(c)
ML19058A467
Person / Time
Site: Prairie Island  Xcel Energy icon.png
Issue date: 03/11/2019
From: Robert Kuntz
Plant Licensing Branch III
To:
Northern States Power Co
Kuntz R, 415-3733
References
EPID L-2018-LLA-0147
Download: ML19058A467 (4)


Text

LICENSEE:

FACILITY:

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 March 11, 2019 Northern States Power Company, a Minnesota Corporation Prairie Island Nuclear Generating Plant, Units 1 and 2

SUBJECT:

SUMMARY

OF FEBRUARY 25, 2019, MEETING WITH NORTHERN STATES POWER COMPANY, DOING BUSINESS AS XCEL ENERGY, RELATED TO THE AMENDMENT REQUEST TO MODIFY RENEWED FACILITY OPERATING LICENSE PARAGRAPH 2.C(4)(c) (EPID NO. L-2018-LLA-0147)

On February 25, 2019, a Category 1 public teleconference was held between the U.S. Nuclear Regulatory Commission (NRC) and representatives of Northern States Power Company, a Minnesota Corporation, doing business as Xcel Energy (the licensee). The purpose of the meeting was to discuss the licensee's response to the NRC staff's request for additional information (RAI), date December 8, 2019 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML18340A205), related to an amendment request to modify renewed facility operating license paragraph 2.C(4)(c). The meeting notice and agenda, dated February 13, 2019, are available at ADAMS Accession No. ML19044A138. A list of attendees is provided as Enclosure 1.

The NRC staff questioned the licensee on the December 8, 2019, RAI response. Specifically, the staff questioned the response related to defense-in-depth, element 3, with respect to the removal of modification 20. The RAI response indicates that re-powering Panel 211 and Panel 213 from Panel 217 to provide process monitoring indication in the main control room remains as a defense in depth action. The licensee also indicates that although a lack of electrical coordination exists between the main fuses and the upstream circuit breaker, electrical coordination is achieved between the branch fuses and the main fuses and, therefore, a fire in Fire Area 31 affecting a branch circuit will not fail the main fuses on Panel 217.

  • Panel 217 will remain available to support re-powering of Panel 211 and Panel 213.

The NRC staff questioned the ability of Panel 217 to remain available to support repowering Panel 211 and Panel 213. The NRC staff questioned if the branch fuses also achieved coordination with the supply breaker upstream of the main fuses. If there is no coordination, an electrical fault in the branch circuits could trip the supply breaker and de-energize Panel 217.

Thus, Panel 217 will not remain available. Therefore, the NRC staff questioned if the branch fuses also achieved coordination with the upstream circuit breaker in order to maintain defense in depth for element 3.

The licensee indicated that the branch fuses do achieve coordination with the upstream circuit breaker. The licensee indicated that they will provide a supplement to the amendment request confirming that information.

Members of the public were in attendance. No questions from the public were received.

Please direct any inquiries to me at 301-415-3733, or Robert.Kuntz@nrc.gov.

Docket No. 50-282 and 50-306

Enclosure:

List of Attendees cc: via Listserv Robert F. Kuntz, Senior ProJ Plant Licensing Branch Ill Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation

LIST OF ATTENDEES FEBRUARY 25, 2019 TELECONFERENCE WITH NORTHERN STATES POWER COMPANY, A MINNESOTA CORPORATION RELATED TO THE AMENDMENT REQUEST TO MODIFY RENEWED FACILITY OPERATING LICENSE PARAGRAPH 2.C(4)(c)

PRAIRIE ISLAND NUCLEAR GENERATING PLANT UNITS 1 AND 2 Nuclear Regulatory Commission (NRC)

Robert Kuntz J.S. Hyslop Thinh Dinh Jay Robinson Northern States Power Company, a Minnesota Corporation (NSPM)

Sara Scott.

Peter Gohdes Brian Slack Greg Kvamme Kamini Balakrishnan Public Jeff Quinn, Engineering Planning and Management (EPM), Inc.

Enclosure

SUBJECT:

SUMMARY

OF FEBRUARY 25, 2019, MEETING WITH NORTHERN STATES POWER COMPANY, DOING BUSINESS AS XCEL ENERGY, RELATED TO THE AMENDMENT REQUEST TO MODIFY RENEWED FACILITY OPERATING LICENSE PARAGRAPH 2.C(4)(c) (EPID NO. L-2018-LLA-0147) DATED MARCH 11, 2019 DISTRIBUTION:

PUBLIC RidsACRS_MailCTR Resource RidsNrrDorlLpl3 Resource RidsNrrPMPrairielsland Resource RidsNrrLASRohrer Resource RidsRgnlllMailCenter Resource JHyslop, NRR TDihn, NRR JRobinson, NRR ADAM s Accession No. Meeting Notice ML19044A138 Meeting Summary ML19058A467 OFFICE NRR/D0RL/LPL3/PM NRR/D0RL/LPL3/LA NRR/D0RL/LPL3/BC NRR/D0RL/LPL3/PM NAME RKuntz SRohrer DWrona RKuntz DATE 2/28/19 2/27/19 3/8/19 3/11/19 OFFICIAL RECORD COPY