I UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION In the Matter of PUBLIC SERVICE ELECTRIC & GAS COMPANY, et al.
)
)
)
)
)
)
)
Docket No.~
(Salem Nuclear Generating Station, Unit 1)
LICENSEE'S RESPONSE TO INTERVENORS' FIRST SET OF INTERROGATORIES TO THE LICENSEE DATED NOVEMBER 21, 1978 Licensee hereby answers all Interrogatories served by intervenors, Alfred and Eleanor Coleman, except_ those Interrogatories to which Licensee has filed objections and a motion for a protective order.
Respectfully submitted,
~:C4r:~
Counsel fo icensee December 11, 1978
- Interrogatory 1
- l.
At p. 2 of the Safety Analysis, the licensee described the alternatives which were considered and "determined to be unsatisfactory" for a variety of reasons.
Please describe the changes, if any, which have taken place in the status of spent fuel reprocessing and the availability of the facilities of the General Electric Company and Nuclear Fuel Services available insofar as they relate to away from reactor ("AFR")
alt~rnatives. For example, have the facilities applied for expansion of spent fuel storage?
Will these facilities be available for reprocessing or AFR storage? If so, when?
If not, why not?
l(a).
Please explairr the basis for the statement (bottom of
- p. 2) that "storage in the existing racks is possible, but only for a short period of time."
How long?
What factors and assumptions underly the time of availability, (e.g.,
fuel burnup, capacity factor of the unit; transshipment, etc.)?
l(b).
Has the licensee considered the alternative in the intervenors' contention 9(D), "ordering the generation of spent fuel to be stopped or restricted", (e.g., operation of the unit with existing racks until an offsite AFR alternative is available.)
If so, llease describe in full.
If not, why not?
Answer
- 1.
Please see answer to Question 4 of our July 31, 1978 response to NRC question.
In addition; as stated in NUREG-0404 Page ES-6, "The General Electric Company's planned reprocessing plant at Morri~,.Illiriois, has now been declared and licensed as an independent spent fuel storage installation.
The initial licensed spent. fuel storage capacity of about 100 MTU has been increased to about 750 MTU by installing spent fuel storage racks in its former high level waste storage pool."
P78 162 31 Ii.
I d*
t:
- e. l(a).
Normally, a third of.a reactor core is discharged into the spent fuel pool yearly.
A third of a core consists of approximatey 65 fuel assemblies.
The existing spent fuel racks have 264 storage locations.
Assuming that a full core discharge capability is not maintained in the spent fuel pool, four yearly discharges can be made until the spent fuel storage is completely depleted~
The design average region discharge burnup is 33,000 MWG/MTU.
The anticipated capacity factor is 68 percent although fuel may be discharged for operational reasons on.close to an annual basi~ even if design values ar~ not achieved.
l(b).
Discontinuing operation of the ~nit has not b~en con-sidered in detail in as much as this would be unacceptably costly to the licensees and its customers.
In addition, the power produced would have to be replaced by fossil fueled units which would result in environmental, economic arid social costs.
See also NUREG-0404 page ES-7, p~ragraph-3.S.
P78 162 32
,~*
rn*terrogatory 2 Please describe why the altern~tive of transshipment to other reactors is not considered a potential alternative.
What reactors have been ~onsidered for transshipment?
Answer
- 2.
Please refer to Question 2 of our July 31, 1978 sub-mittal.
Moreover the alternatives of transshipment does not offer environmental nor economic advantages.
See also NUREG-0404 page 3-27 paragraph 3.2 which states, "it would be unrealistic to think that ~ utility with some excess storage space would prematurely fill up its pool with spent fuel from another utility."
P78 161 10 I
II,.
- 1.
... \\
- e.
Interrogatory 3
- Please provide a full update of the licensee's plans for discharge of spent fuel, the first batch of which is planned eor discharge in January, 1979 (p. 3).
-: Answer The first fuel discharge into the spent fuel pool is now scheduled for April, 1979.
Subsequent refuelings are planned at approximately one year intervals.
See also response to interrog~tory 1 (a)
- P78 161 01
,;i
':'r
=r*
,\\
. (
e Interrogatory 4 Please provide the basfs and all calculations underlying the licensee's statement that "the additional cost to our cus-tomers for purchase of replacement power is estimated to be approximately $500,000 for each day the reactor is not operating."
Answer See response to NRC Question S(a) dated July 31, 1978.
P78 162 27
Interrogatory 5 Has the licensee evaluated the effect, if any, of a recom-mendation by the Generic Environmental Impact Statement on the Handling and Storage of Spent Fuel, NUREG-0404 in favor of (AFR) facilities?
If so, please describe; if not, please state the reasons.
Answer As stated in NUREG-0404 page ES -
6, "The methods of expanding spent fuel storage capacity considered in this assessment show negligible difference in environmental impact and cost with the exception that at-reactor storage pool compact
- 1 storage is least costly economically, and does not require additional transportation of spent fuel.
NUREG-0404 cotitem-plates the use of AFR storage in addition to AR storage such as being requested for Salem 1.
- "i.
P78 161 02
Interrogatory 6 What increase would occur in radiation levels in the storage water of the spent fuel pool in the event that the licensee's application is granted?
(see p. 7) 6(a).
What increase in radioactive materials and in radiation levels would occur in the coolant water filters?
What increase would occur in the screens, traps, drains and pipes?
Please provide all relevant calculations and the basis therefore.
6(b).
Please explain the statement at p. 8 that "the amount of corrosion products released into the pool during any year would be the same regardless of the storage capacity of the pool," assuming increased compaction and several years of discharged fuel?
Answer
- 6.
The spent fuel pool water clean-up system is designed to process the radioactivity releas~d to the water from storage of (1/3 core) spent fuel assemblies on an annual basis.
During this time period, this radioactivity (including corrosion and activation products) will be reduced to negligible levels by being removed from the water by the clean-up system and radioactive decay.
Each subsequent dis-charge* of spent fuel assemblies will be placed in the storage i
pool approximately a year after placement of the prior dis-charge and the clean-up system, during the next one year period, removes the.activity in the water.
The radioactivity being removed is predominantly from the most recently dis-charged fu~l.
The contribution from the fuel discharged in prior years is negligible.
Hencei the design basis of the spent fuel pool clean-up system is unaffected by the number P78 162 29
.... o f spent fuel pool storage locations, i.e., the request for additional fuel storage capacity.
6(a).
Based on the response to Interrogatory 6, we do not expect an increase in radioactive mat~rials on filters, in traps,, screens,. drains or pipes.
6(b).
See response to Interrogatory 6
- P78 162 30
e e
Interrogatory 7 If the quantity of spent fuel is increased by a factor of four (4), how would the crud release rate be affected?
Similarly, how would the total quantity of radioactive materials released into the spent fuel pool be affected?
(see p. 9)
Answer
- 7.
See response to Interrogatory 6.
P78 161 65 II,*
J
Interrogatory 8 Please* quantify the amount of corrosion products which would be present in the spent fuel pool as a result of increased pompaction.
- Answer
- . ::8.
- See response to Interrogatory 6.
Our response submitted on July 31, 1978 to NRC question 11, tabulates the concen-trations of principal radionuclides expected to be found in the spen~ fuel pool water *
. **l, P78 161 64
e Interrogatory 9 Please explain why the "resin replacement frequency will not be significantly altered by the increase in spent fuel storage capacity" (p. 9).
Please describe how reliance on the "differential pressure increase".differs from the "loss of
)
~capacity to remove radioactive contaminants" irt determinirig resin replacement (p. 8).
Show calculations for predictions in each case.
Answer
- 9.
See response to interrogatory 6.
It is expected that pressure differential wil be the controlling factor in filter and resin replacement.
The demineralizers are also used to
,;i
\\
remove radioactivity by the process of ion exchange.
It is possible that in order to reduce exposure to plant personnel this process would lead to the replacement of resin due to
'."1,
high radioactivity level to increase prior to a high pressure differential indication.
A water sampling procedure will also be utilized to assure that the capacity to remove radioactive contaminants is fuaintained in the demineralizer.
P78 162 28
INTERROGATORY 10 What other gasses beside Kr 85 may be released from a spent fuel storage area (page 10)?
Please identify and quantify.
ANSWER Other radioactive gases that might be released from the spent fuel pool consist of radioactive xenons sucn as Xe-l3lm, Xe-133 and Xe-135, tritium (H-3) and radioactive iodines such as I-131 and I-133.
However, because of the half lives of those isotopes (except H-3) relative to Kr-85, the curies released of these isotopes will be substantially lower than the amount indicated for Kr-85 and the release will occur approximately during the first two months of fuel storage.
Hence, increased fuel storage time will not result in any increase in releases to the environment of other radioactive gases.
The amount of gaseous tritium released from the spent fuel pool area is estimated to be 240 curies per year as a result of evaporation of water from the pool.
No additional tritium release is ex-pected as a_result of increased fuel storage time since the prime sources of tritium in reactor water are ternary.fission and neutron activation of other_ isotopes in the water. -Essentially, no fission or neutron activation wiLl take place in the fuel storage
_pool.
INTERROGATORY lO(b)
Why is there intended to be no separate monitoring device to measure radioactive gases released from ~he spent fuel storage area?
Identify any impediments to such a monitoring system, if any.
ANSWER A separate monitoring device is not necessary as all potentially radioactive station effluent, including air from above the spent fuel pool is monitored prior to discharge from vent.
The concentrations of gaseous activity arourid the spent fuel pool are expected to be below the lower range of commercially available continuous gas monitors.
II I.
~
QUESTION NO. 11 Please describe how the Table 2.0-1 (p. 39) relates to the, determination of expected radioactive gases released from the spent fuel storage area during the period of storage ?
ANSWER Table 2.0-1 does not directly relate to the expected release of gases from the spent fuel storage area~
The reason for including this Table was to.illustrate that the total gaseous radioactive releases from Salem Unit No. i in 1976 and 1977 (first half) were very small in magnitude.
ii I.
~
INTERROGATORY ll(a)
~hat is the purpose of Table 2.0-1?
'.ANSWER Refer to the response to Interrogatory 11.
~: ;
,\\
INTERROGATORY ll(b)
What is the lower limit of detection applicable to Table 2.0-1?
ANSWER The lower limits of detection for those isotopes presented in
-4
-12 Table 2.0-1 are 10
µ Ci/ml for Kr-85, 10
µ Ci/ml for I-31 and 10-6µ Ci/ml for tritium.
- 11.
I
.I*
INTERROGATORY ll(c)
What techniques are available for measuring below this limit?
ANSWER The amount of radioactivity estimated to be released to the environment from the spent fuel storage pool is very small and does not have any environmental significance.
Furthermore, the plant effluent radiation monitoring system is capable of measuring radioactive releases that are a small fraction of the applicable Technical Specification release limit.
As a result, PSE&G has not investigated any techniques for measuring below the indicated limits of detection*
Interrogatory 12 At page 14, you desciibe the "B-10 loading of 0.025 gm/cm2."
Please explain this value in light of Table 3.1-1 which refers to 0.05 gm/cm2 as minimum and Table 3.1-4 which shows 0.025 gm/cm2 as minimum.
Answer The February 14, 1978 PSE&G license amendment submittal delineates a change in boron loading from 0.025 to 0.020 gms B-10/cm2 in each Baral plate.
There are two poison plates utilized between fuel assemblies in the Salem storage racks.
Consequently, the total B-10 loading between two adjacent fuel assemblies is (2)
~
(0.02) = 0.04 grns B-10/cm2.
Therefore table 3-1-4 and page 14 are not inconsistent.
P78 161 03
Interrogatory 12 (a)
What are the correct values and the B-10 loadings?
Answer 12 (a)
See response to Interrogatory 12.
P78 161 04 II,.
J.
- j
- ~.\\
I~
. 1**1 Yj e
Interrogatory 12 (b)
What is the uncertainty of the value of the expected loadings?
Answer 12 (b)
The value of.02 gms B-10/cm2 is a minimum value
- To assure that the minimum value is achieved in each Boral
- plate, a higher average concentration of ~4C is utilized during the fabrication.
Additional tests are made after fabrication to assure that the minimum boron levels are achieved.
P78 161 05
Interrogatory 13 f
Please describe why the licensee believes that the increased spent fuel compaction and storage will not affect the con-sequences of a spent fuel pool accident (seep. 21).
Explain how the consequences of an accident would be affected by acts of sabotage.
Answer
- 13.
Please refer to NRC questions on the same subject in our July 21, 1978 submittal and Question 15 of our October 13, 1978 submittal.
As shown in the answers to these questions, the consequences of a spent fuel pool accident are not affected.
P78 161 06
'9.
Interrogatory 14 Please describe how the fuel cask would be handled and the basis for the chosen method.
- Also, please describe the specific controls to be employed to assure that the cask handling does not encroach upon the pool area.
Answer
- 14.
The cask handling crane is designed such that it is physically impossible for it to travel over the spent fuel pool.
P78 161 07
Interrogatory 15 Please describe the basis for*the statement at p. 22 that "there is no deterioration or corrosion of stainless steel in this environment."
(emphasis added)
Please describe the variables which affect the rate of deterioration or corrosion, if any.
What assumption underly the determination that no deterioration or corrosion will occur?
Answer
- 15.
Stainless steel of the type being used in the spent fuel racks at Salem 1 has been widely utilized in the nuclear industry.
We are not aware of any corrosion of stainless steel in environments similar to the Salem 1 spent fuel pool.
P78 161 08 11 j.
Interrogatory 16 Please describe the "non-destructive testing of the cells".
Answer
- 16.
Non-destructive testing of.fuel cells is addressed in the October 31, 1978 submittal in the answer to question "Provide a description of the procedures used t~ insure that the fuel storage racks are leak tight."
P78 161 09 I
- e.
Interrogatory 16(a)
What would the consequences of a less than 100 percent leak tightness?
Answer 16(a).
The consequences of less than 100 percent leak tight-ness are described in Exxon Nuclear Company document XN -
NS -
009 entitled "ENC Fuel Storage Racks Corrosion Program Boral -
Stainless Steel -
PROPRIETARY."
The October 31, 1978 sub-mittal to teh NRC documents the results of tests performed by Exxon Nuclear to characterize the effects of a fuel cell that develops a leak in the fuel storage pool environment.
These two reports demonstrate that there are. no safety implications associated with less than 100% leak tightness.
P78 161 13 Ji.
I
.I*
- ~
\\
Interrogatory 16(b)
Describe the basis for the 95 percent confidence level, including any calculations and methodologies.
':Answer
'.16(b).
The statistical basis for satisfying the 95 percent confidence level is discussed in the October 31, 1978 sub-mittal to the NRC which addresses" *** the procedures used to insure that the fuel storage racks are leak tight."
Essentially, the helium mass spectrometer leak test program
- i
~'
is used as an overcheck to assure the 95 percent confidence level.
The leak test sampling frequency of the fuel cell was chosen to satisfy a statistical 95/95 tolerance limit, as explained in the submittal.
The leak test progtam is designed to qualify the entire pro-auction of fuel storage cells to the 95/95 tolerance limit, as one lot.
The lot is split into several sublots for pur-v poses of production control.
Sample cells are selected at constant intervals from each sublot.
Each sublot must meet a specified acceptance limit, in order to insure that the entire production meets the 95/95 tolerance limit.
The statistical methods used in this type of sampling pro-gram are explained in the paper:
non the Use of Tolerance Intervals in Acceptance Sampling by Attributes," by J. L.
Jaech, Journal of Quality Technology, Volume 4, No. 2, April 1972.,
P78 161 14
- <~.
Interrogatory 17 If in-pool surveillance finds problems requiring repair of spent fuel rods or racks, what are the licensee's contin-gency plans for removal and repair?
- Answer
- 17.
The October 31, 1978, submittal to the NRC describes the actions required to remove a fuel assembly from a swollen fuel cell.
P78 161 15
..1 __
- _T'.G::
Interrogatory 22 The ca1culated Reff values for ORNL Critical Lattices (p. 46) cases four and five sets forth central values which are outside the range of values for the 95 percent confidence level.
Please explain how it is possible for the central value and Keff to be outside the range of values provided in the table.
Answer Please see answer to Question 12 in our May 17, 1978 sub-mittal to the NRC.
~*',.. ~~.~--
- -*--*~:..-...... -....
P78 161 16
... *{**..,,
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION Before the Atomic Safety and Licensing Board In the Matter of
)
)
PUBLIC SERVICE ELECTRIC AND GAS
)
COMPANY, et al.
)
)
(Salem Nuclear Generating
)
Station, Unit 1)
- )
Docket No.
50-272 CERTIFICATE OF SERVICE I hereby certify that copies of "Licensee's Response*
to Intervenors*' First* Set of Interrog.atories to the Licensee Dated November 21, 1978", in the captioned matter, have been served upon the following by deposit in the United States mail this 11th day of December, 1978:
Gary L. Milhollin, Esq.
Chairman, Atomic Safety and Licensing Board 1815 Jefferson Street Madison, Wisconsin 53711 Mr. Glenn O. Bright Member, Atomic Safety and*
Licensing Board Panel U.S. Nuclear Regulatory Commission Washington, D.C.
20555 Dr. James C. Lamb, III Member, Atomic Safety and Licensing Board Panel 313 Woodhaven Road Chapel Hill, N.C.
27514 Chairman, Atomic Safety and Licensing Appeal Board Panel U.S. Nuclear Regulatory Commission Washington, D.C.
20555 Chairman, Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Washington, D.C.
20555 Barry Smith, Esq.
Off ice of the Executive Legal Director U.S. Nuclear Regulatory Commission Washington, D.C.
20555 Mark L. First, Esq.
Deputy Attorney General Department of Law and Public Safety -
Environmental Protection Section
- 36. West State Street Trenton, N.J.
08625
Mark J. Wetterhahn, Esq.
Conner, Moore & Corber
~.'2 *-
. 1747 Pennsylvania Avenue, N.W.
.Washington, n~*c. 20006 R. William Potter, Esq.
Assistant Deputy Public Advocate Department of the Public *Advocate*
Division.of Public Interest Advocacy
- Post Office Box 141 Trenton, N. J.
08601 Sandra T. Ayres, Esq.
Department of the Public Advocate 520 East State Street Trenton, N. J.
08625 Mr. Alfred C. Coleman, Jr.
Mrs. Eleanor G. Coleman 35 "K" Drive Pennsville, New Jersey 08070 Carl. Valore, Jr., *Esq.
Valore, McAllister,.Aron
& Westmoreland Mainland Professional Plaza J>. O. Box 175 Northfield, *w *. J.
1t>8225 Office of the *Secretary*
Docketing and Service Section U.S. Nuclear Regula.tor}'
Commission Washington, D.C.
20555 June D. MacArtor, Esq.
Deputy Attorney General Tatnall Building, P. O. Box 1401 Dover, Delaware 19901
VERIFICATION EDWIN A. LIDEN, being duly sworn, states that he is Project Licensing Manager - Salem Nuclear Generating Station of Public Service Electric and Gas Company; that he has been duly authorized to execute, verify and file the foregoing document, "Licensee's Response to Intervenors' First Set Of Inter:cogatories To The Licensee Dated November 21, 1978"; that he has read the contents of same and that the statements contained therein are true and correct to his best information, knowledge and belief.