MONTHYEARTSTF-18-02, Technical Specifications Task Force - Transmittal of TSTF-569, Revision 0, Revise Response Time Testing Definition2018-02-0808 February 2018 Technical Specifications Task Force - Transmittal of TSTF-569, Revision 0, Revise Response Time Testing Definition Project stage: Request ML18057A1602018-03-26026 March 2018 Acceptance for Review Regarding Traveler TSTF-569, Revise Response Time Testing Definition, Project stage: Acceptance Review ML18134A0752018-05-21021 May 2018 Request for Additional Information (RAI) Technical Specifications Task Force (TSTF) Traveler TSTF-569, Revise Response Time Testing Definition Project stage: RAI ML18145A3032018-05-25025 May 2018 License Amendment Request to Revise Technical Specifications Regarding Response Time Testing of Pressure Transmitters Project stage: Request ML18256A0272018-10-31031 October 2018 Traveler TSTF-490, Revision 0, Deletion of E Bar Definition and Revision to RCS Specific Activity Tech Spec Project stage: Other TSTF-18-06, TSTF Response to NRC Questions on TSTF-569, Revise Response Time Testing Definition2018-10-31031 October 2018 TSTF Response to NRC Questions on TSTF-569, Revise Response Time Testing Definition Project stage: Other ML19031C9052019-01-31031 January 2019 Supplemental License Amendment Request to Revise Technical Specifications Regarding Response Time Testing of Pressure Transmitters and Request for Additional Information Response Project stage: Supplement ML19017A2222019-05-29029 May 2019 Letter Transmitting Draft Safety Evaluations of Technical Specifications Task Force Traveler TSTF-569, Revision 1, Revise Response Time Testing Definition Project stage: Draft Approval ML19017A2202019-05-29029 May 2019 Draft Safety Evaluation of Technical Specifications Task Force Traveler TSTF-569, Revision 1, Revise Response Time Testing Definition (Enclosure 1) Project stage: Draft Approval ML19017A2172019-05-29029 May 2019 Draft Model Safety Evaluation of Technical Specifications Task Force Traveler TSTF-569, Revision 1, Revise Response Time Testing Definition (Enclosure 2) Project stage: Draft Approval TSTF-19-06, TSTF Comments on Draft Safety Evaluations for Traveler TSTF-569, Revision 1, Revise Response Time Testing Definition2019-06-25025 June 2019 TSTF Comments on Draft Safety Evaluations for Traveler TSTF-569, Revision 1, Revise Response Time Testing Definition Project stage: Draft Other ML19176A1882019-06-25025 June 2019, 14 August 2019 Final Safety Evaluations of Traveler TSTF-569, Revision 2, Revise Response Time Testing Definition Project stage: Request ML19176A1912019-08-14014 August 2019 Final Safety Evaluation of Traveler TSTF-569, Revision 2, Revise Response Time Testing Definition (EPID L-2018-PMP-0002) (Enclosure 1) Project stage: Approval ML19176A1902019-08-14014 August 2019 Final Model Safety Evaluation of Traveler TSTF-569, Revision 2, Revise Response Time Testing Definition (EPID L-2018-PMP-0002) (Enclosure 2) Project stage: Approval ML19176A1892019-08-14014 August 2019 Cover Letter Transmitting Final Safety Evaluations of Traveler TSTF-569, Revision 2, Revise Response Time Testing Definition Project stage: Approval RS-19-092, Application to Revise Technical Specifications to Adopt TSTF-569, Revise Response Time Testing Definitions2019-12-0909 December 2019 Application to Revise Technical Specifications to Adopt TSTF-569, Revise Response Time Testing Definitions Project stage: Request 2018-05-25
[Table View] |
Text
May 29, 2019 Technical Specifications Task Force 11921 Rockville Pike, Suite 100 Rockville, MD 20852
SUBJECT:
DRAFT SAFETY EVALUATIONS OF TECHNICAL SPECIFICATIONS TASK FORCE TRAVELER TSTF-569, REVISION 1, REVISE RESPONSE TIME TESTING DEFINITION (EPID L-2018-PMP-0002)
Dear Members of the Technical Specifications Task Force:
By letter dated October 31, 2018 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML18304A026), the Technical Specifications Task Force (TSTF) submitted to the U.S. Nuclear Regulatory Commission (NRC) for review and approval Traveler TSTF-569, Revision 1, Revise Response Time Testing Definition. The NRC staffs draft safety evaluation (SE) of the traveler and a draft model SE are enclosed.
Thirty calendar days are provided for you to comment on any factual errors or clarity concerns contained in the enclosed draft SEs. The final SEs will be issued by August 29, 2019, after making any necessary changes. To facilitate the NRC staff's review of your comments, please provide a marked-up copy of the draft SEs showing proposed changes and provide a summary table of the proposed changes.
If you have any questions, please contact Michelle Honcharik at 301-415-1774 or via e-mail at Michelle.Honcharik@nrc.gov.
Sincerely,
/RA/
Peter J. Snyder, Acting Chief Technical Specifications Branch Division of Safety Systems Office of Nuclear Reactor Regulation Project No. 753
Enclosures:
- 1. Draft Traveler SE
- 2. Draft Model SE cc: See next page
Technical Specifications Task Force Project No. 753 cc:
Technical Specifications Task Force c/o EXCEL Services Corporation 11921 Rockville Pike, Suite 100 Rockville, MD 20852 Attention: Brian D. Mann E-mail: brian.mann@excelservices.com James P. Miksa Entergy Nuclear Operations, Inc.
Palisades Nuclear Power Plant 27780 Blue Star Memorial Highway Covert, MI 49043 E-mail: jmiksa@entergy.com Jordan L. Vaughan Duke Energy EC07C / P.O. Box 1006 Charlotte, NC 28202 E-mail: jordan.vaughan@duke-energy.com Ryan M. Joyce Southern Nuclear Operating Company 3535 Colonnade Parkway / Bin N-274-EC Birmingham, AL 35243 E-mail: rmjoyce@southernco.com David M. Gullott Exelon Generation 4300 Winfield Road Warrenville IL 60555 E-mail: David.Gullott@exeloncorp.com Wesley Sparkman Southern Nuclear Operating Company 3535 Colonnade Parkway / Bin N-226-EC Birmingham, AL 35242 E-mail: wasparkm@southernco.com
Package: ML19017A219, Cover letter: ML19017A222, Draft traveler SE: ML19017A220, Draft model SE: ML19017A217
- concurred via e-mail NRR-106 OFFICE NRR/DORL/LSPB/LA*
NRR/DORL/LPL3/BC*
NRR/DE/EICB/BC*
NAME JBurkhardt DWrona MWaters DATE 5/10/2019 5/28/2019 2/8/2019 OFFICE OGC/NLO*
NRR/DSS/STSB/PM*
NRR/DSS/STSB/BC NAME JWachutka MHoncharik PSnyder DATE 5/23/2019 5/29/2019 5/29/2019