ML18353A959

From kanterella
Jump to navigation Jump to search

Letter - Request for Additional Information - License Amendment Request 18-04 Addition of MCNP6 for Nuclear Criticality Safety Analysis
ML18353A959
Person / Time
Site: 07003103
(SNM-2010)
Issue date: 01/08/2019
From: Jacob Zimmerman
NRC/NMSS/DFCSE/FLB
To: Padgett W
Louisiana Energy Services
KJSturzebecher NMSS/FCSE/FLB 415.8534
Shared Package
ML18353A957 List:
References
EPID L-2018-LLA-0270
Download: ML18353A959 (2)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 January 8, 2019 Mr. Wyatt Padgett Licensing and Performance Assessment Manager Louisiana Energy Services, LLC P.O. Box 1789 Eunice, NM 88231

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION - LICENSE AMENDMENT REQUEST 18-04 ADDITION OF MCNP6 FOR NUCLEAR CRITICALITY SAFETY ANALYSIS (ENTERPRISE PROJECT IDENTIFIER: L-2018-LLA-0270)

Dear Mr. Padgett:

By letter dated September 13, 2018 (Agencywide Documents Access and Management System

[ADAMS] Accession Number ML18262A215), Louisiana Energy Services, LLC dba URENCO USA (UUSA), requested that the U.S. Nuclear Regulatory Commission (NRC) approve an addition to the existing Nuclear Criticality Safety Validation Report with an amendment to the UUSAs Safety Analysis Report for Material License SNM-2010.

The NRC staff has evaluated your request and based upon our review we require additional information to assist us in completing our review. This request for additional information is detailed within the enclosure. Your response and the information should be provided to us within 30 days of the date on this letter.

In accordance with Title 10 of the Code of Federal Regulations Section 2.390 of the NRCs Agency Rules of Practice and Procedure, a copy of this letter and enclosure are available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records component of NRCs ADAMS. ADAMS is accessible from the NRC Web site at: http://www.nrc.gov/reading-rm/adams.html. If you have any questions regarding this matter, please contact Mr. Karl Sturzebecher at 301-415-8534, or via email at Karl.Sturzebecher@nrc.gov.

Sincerely, RA Kevin Ramsey Acting for/

Jacob I. Zimmerman, Chief Fuel Facility Licensing Branch Division of Fuel Cycle Safety, Safeguards, and Environmental Review Office of Nuclear Material Safety and Safeguards Docket No. 70-3103 License No. SNM-2010

Enclosure:

Request for Additional Information

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION - LICENSE AMENDMENT REQUEST 18-04 ADDITION OF MCNP6 FOR NUCLEAR CRITICALITY SAFETY ANALYSIS (ENTERPRISE PROJECT IDENTIFIER: L-2018-LLA-0270)

DATED: January 8, 2019 DISTRIBUTION: FCSE r/f FFLB r/f MKotzalas,LOB LPitts, RII OLopez, RII JRivera, RII RNease, RII ADAMS Package Accession Number: ML18353A957 ML18353A959 (Ltr) *via email OFFICE FCSE/FFLB FCSE/FFLB FCSE/FFLB NAME KSturzebecher TBrockington JZimmerman DATE 12/18/2018 1/08/2019 1/08/2019 OFFICAL RECORD COPY