Text
..
e I '
consumers Power company Palisades Nuclear Plant: Route 2, Box 154, Cov,ert, Michigan 4904:f',
l... :J September 1, 1978 U.S. Nuclear Regulatory Commission Mail and Records Section Washington, D.C., 20555 Re:
LICENSE REPORT OF MONTHLY OPERATING DATA DPR-20, DOCKET NO. 50-255 Gentlemen:
Enclosed is a copy of the *Monthly Operating Data, and a Summary of Operating Experience for the Palisades Nuclear Plant for the month of August 1978 *
. *WEAdarns, General Engineer cc:
JGKeppler, USNRC RBDeWitt DAB ix el GHPetitjean CVWaits DEVanFarowe, Div. of Radiological Health Lansing, Mich.
AKozlowski, Mich. Dept. of Labor RCallen, 'Mich. Public Serv. Comm., Lansing, MI.
Document Control -
(2) - 950-22.35.10
~.. -: 1 *1**1
~.. C.J
(_
dfr~.
W1>
- ~~~~.... -'
AVERA.GE DAILY UNIT POWER LEI MONTH AUGUST 1978 DAY AVERAGE DAILY POWER LEVEL (MWe-Net) 2 3
- 4 5
6 17 7
428 8
71 9
544 10 616 l l 603 12 610 13 578 572 14 15 532 16 543 INSTRUCTIONS DAY 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 DOCKET NO.
UNIT DATE COMPLETED BY TELEPHONE 50-25.5 Palisades 9-1-78 DIBollnow 616-764-8913 AVERAGE DAILY POWER LEVEL (MWe-Net) 552 545 548 631 633 632 608 588 585 579 578 232 On this format, list the average daily unit power level in MWe-Net for each day in the reporting Inlinth. Compute to.
the nearest whole megawatt.
(9/77)
If~*
\\
':.~-
(
OPERATING DATA REPORT OPERATING STATUS I. Unit Name:
. 2. Reporting Period:
- 3. Licensed Thermal Power (MWt):
- 4. Nameplate Rating (Gross MWe):
Palisades 780801 to 780831 2530 811. 7 805
- 635
- 5. Design Electrical Rating (Net MWe):
- 6. Maximum Dependable Capacity (Gross MWe):
- 7. Maximum Dependable Capacity (Net MWe):
- 675 Notes DOCKET NO.
DATE COMPLETED BY TELEPHONE
. 50-255 9-1-78 DIBollnow 616-764-8913
- 8. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report, Give Reasons:
- 9. Power Level To Which Restricted, If Any (Net MWe):
- 10. Reasons For Restrictions, If Any:
This Month Yr.-to-Date
- 11. Hours In Reporting Period
- 12. Number Of Hours Reactor Was Critical 744.
516.1 5831 2,853.6
- 13. Reactor Reserve Shutdown Hours
- 14. Hours Generator On-Line 496.L 2,524.9
- 15. Unit Reserve Shutdown Hours
- 16. Gross Thermal Energy Generated (MWH)
- 17. Gross Electrical En~rgy Generated (MWH)
- 18. Net Electrical Energy Generated (MWH) 1,049,064-298,650 277,856 5,182,032 1,523,270 1,418,444
- 19. Unit Service Factor 66.7 43.3
- 20. Unit Availability Factor 66.7 43.3
- 21. Unit Capacity Factor (Using MDC Net) 58
- 8 38.3
- 22. Unit Capacity Factor (Using DER Net)
- 46. 4
- 23. Unit Forced Outage Rare 18
- 2 30.2 16.6
- 24. Shutdowns Scheduled Over Next 6 M~nths (Type. Date. and Duration of Each):
- 25. If Shut Down At End Of Report Period, Estimated Date of Startup:
- 26. Units In Test Status (Prior to Commercial Operation):
INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION.
Forecast Cµmulative 58,742 32,253.0 30,357.1 55,203,696*
17,109,880 16,031~811
- 51. 7
- 51. 7 43.0 33.9 39.0 Achi~ved
- Based on Condenser Backpressure Limitations (9/77)
_,,,,... ~...--.,............. --~-----*-*-------**-*- *--**
Nu::
Date 17 780731 18
- 780807 19 780828 19-F: Forced S: Scheduled
. \\
(9/77)
UNIT SHUTDOWNS AND POWER REDUCTIONS REPORT MONTH August 1978
- 0.
I-..
s F
F Reason:
137.6 20.0 90.3 I"!
B 3
A 3
B 1
A-Equipment Failure (Explain) 13-Mainten:.ince or Test
('-Refueling D-Rcgulatory Restriction Licensee Event Report it
- N/A N/A N/A E-Operntor Training & License Examination F-Administrative 3
Method:
I-Manual 2-Manual Scram.
3-Automatic Scram.
4-0thcr (Explain)
G-Operntional Error (Explain)
II-Other (Explain)
DOCKET NO.
UNIT NAME DATE COMPLETED BY TELEPHONE Cause & Corrective Action to Prevent Recurrence Repairs to CRDM Seals Feedwater Punip Trip Repairs.to CRDM Seals 4*
50-255 Palisades 9-6-78 DIBollnow 616-764-8913 Exhibit G
- Instructions for Preparation of Data Entry Sheets for Licensee 5
Event Report ( LER) Filr (NUREG-0161)
Exhibit I_* Same Soun:c
CONSUMERS POWER COMPANY PALISADES NUCLEAR PLANT DOCKET 50-255
SUMMARY
OF OPERATING EXPERIENCE FOR AUGUST 1978 GENERAL Except for the outages discussed below, the Plant operated in the range of 80% to 90% of full power during the month.
At the beginning of the month, the Plant was shutdown in continuation of an outage which had begun on July 31st.
As of August 1st, this outage had been in progress for 2.3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br />.
SPECIFIC ITEMS OF INTEREST 8-6-78 8-7-78 8-28-78 The Plant was returned to operation, ending a 137.6 hour6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> outage.
During the outage, repairs were made to six CRDM seals and oil was added to the 'A' Primary Coolant Pump.
During this outage, testing and repair of the Containment Building purge valve T-ring air supplies was connnenced.
This testing and maintenance effort on the seven valves (CV-1803, 1805, 1806, 1807, 1808, 1813 and 1814) continued throughout the month.
A Plant trip caused by low Steam Generator water level occurred subsequent to the loss of the 'B' Feedwater Pump.
The outage lasted for 20.0 hours0 days <br />0 hours <br />0 weeks <br />0 months <br />.
During this outage, insulation of boric acid piping was completed, and a ruptured disc on the No. 1 low pressure turbine was replaced.
The Plant was shutdown to permit repairs to CRDM seals and to replace the seal on 'B' Primary Coolant Pump.
As of the end of the month, this outage had been in progress for 90.3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br />.