ML18340A171

From kanterella
Jump to navigation Jump to search

Shine Medical Technologies, Inc. - Acknowledgement of Receipt of Periodic Report on Construction Permit Conditions
ML18340A171
Person / Time
Site: SHINE Medical Technologies
Issue date: 12/10/2018
From: Steven Lynch
Research and Test Reactors Licensing Projects Branch
To: Piefer G
SHINE Medical Technologies
Lynch S
References
EPID L-2017-PMP-0014
Download: ML18340A171 (4)


Text

December 10, 2018 Gregory Piefer, Ph.D.

Chief Executive Officer SHINE Medical Technologies, Inc.

101 E. Milwaukee Street, Suite 600 Janesville, WI 53545

SUBJECT:

SHINE MEDICAL TECHNOLOGIES, INC. - ACKNOWLEDGMENT OF RECEIPT OF PERIODIC REPORT ON CONSTRUCTION PERMIT CONDITIONS (EPID NO. L-2017-PMP-0014)

Dear Dr. Piefer:

In order to verify certain design developments related to nuclear criticality safety (NCS) and radiation protection in the SHINE Medical Technologies, Inc. (SHINE) radioisotope production facility (RPF), the U.S. Nuclear Regulatory Commission (NRC) collects periodic reports containing the information set forth in Section 3.D.(1) of SHINE Construction Permit No. CPMIF-001.

By letter dated August 22, 2018 (Agencywide Documents Access and Management System Accession No. ML18234A020), SHINE submitted to the NRC its fifth periodic report on NCS and radiation protection consistent with Section 3.D.(1) of its construction permit, CPMIF-001.

As described in its fifth periodic report, SHINE has performed work on the five license conditions described in Section 3.D.(1) of its construction permit. In support of developing the technical basis for the design of the criticality accident alarm system in License Condition 3.D.(1)(a),

SHINE has contracted the work necessary to determine detector placement and response functions to meet the requirements of Title 10 of the Code of Federal Regulations (10 CFR) 70.24, Criticality accident requirements, paragraph (a), including development of a minimum accident of concern and transport source terms.

With respect to the criticality safety considerations described in License Conditions 3.D.(1)(b) - (d), SHINE indicated that it has developed criteria for determining that criticality events are not credible for RPF processes even though fissile materials may be present; begun drafting NCS evaluations for various systems; and evaluated reactivity contributions from all fissile isotopes to demonstrate that all RPF processes remain subcritical under all normal and credible abnormal conditions.

According to its fifth periodic report, SHINE has developed additional design information for the RPF supercells, tank vaults containing the liquid waste storage tanks, evaporation hot cells, and liquid waste solidification hot cells to determine tank vault sizing, tank elevations, facilities locations, and supercell shielding requirements. SHINE has also determined shield plug thickness and drip pan requirements for tank and carbon delay bed vaults, valve pits, and pipe trenches. This information will be used to demonstrate that shielding and occupancy times within the RPF are consistent with as low as is reasonably achievable practices and dose

requirements of 10 CFR Part 20, Standards for Protection Against Radiation, as described in License Condition 3.D.(1)(e).

As of the writing of this letter, SHINE has neither initiated construction of its proposed facility nor submitted any additional design information as part of an operating license application or amendment to its construction permit for NRC review under Docket No. 50-608.

Based upon the information provided in SHINEs periodic reports, the status of activities authorized under Construction Permit No. CPMIF-001, and the status of applications submitted under Docket No. 50-608, no NRC action is necessary on SHINEs periodic reports at this time.

The NRC may request that SHINE provide clarifying or more detailed information in order to verify certain design developments as set forth in Section 3.D.(1) of SHINEs construction permit if the NRC considers this information necessary prior to the completion of construction. This may include requests that SHINE make reference material available through an electronic reading room or meet with NRC staff to support the planning and conducting of NRC inspections during construction.

If you have any questions, please contact Steven Lynch at 301-415-1524, or by electronic mail at Steven.Lynch@nrc.gov.

Sincerely,

/RA/

Steven T. Lynch, Project Manager Research and Test Reactors Licensing Branch Division of Licensing Projects Office of Nuclear Reactor Regulation Docket No. 50-608 cc: See next page

SHINE External Stakeholder Mailing List Jeff Bartelme Licensing Manager SHINE Medical Technologies, Inc.

101 E. Milwaukee Street, Suite 600 Janesville, WI 53545 Jeff Chamberlin National Nuclear Security Administration, NA-231 U.S. Department of Energy 1000 Independence Ave SW Washington, DC 20585 Mark Paulson Supervisor Radiation Protection Section Wisconsin Department of Health Services P.O. Box 2659 Madison, WI 53701-2659 Test, Research and Training Reactor Newsletter P.O. Box 118300 University of Florida Gainesville, FL 32611 Mark Freitag City Manager P.O. Box 5005 Janesville, WI 53547-5005 Bill McCoy 1326 Putnam Avenue Janesville, WI 53546 Alfred Lembrich 541 Miller Avenue Janesville, WI 53548 Gerald and Muriel Bumgarner 1735 S Osborne Ave Janesville, WI 53546

ML18340A171; *concurred via email NRR-088 OFFICE NRR/DLP/PRLB/PM NRR/DLP/PROB/LA*

NRR/DLP/PRLB/BC NAME SLynch NParker AAdams DATE 12/04/2018 12/10/2018 12/10/2018 OFFICE NRR/DLP/PRLB/PM NAME SLynch DATE 12/10/2018