Drawing 02-1150959-D, Rev. 4, Filter Canister Upper Head Weldment
ML18331A300
Person / Time
Site: 07200020
(SNM-2508)
Issue date: 08/31/1984
From:
US Dept of Energy, Idaho Operations Office, Babcock & Wilcox
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML18331A065 List: ... further results
References
CLN190271 Drawing 02-1150959-D, Rev. 4
Download: ML18331A300 (1)


Text

For Information Only D

C B

A ON B

,4DD L.ET7El<!AIG PcR:. N'OT 4-z

'l.00 7

YHl:5 S"URFAC~

/VJU.:ST /\\/07

!'EXTEND BEYo.N'D

~

5 B

5 I

7 6

~

A."uD St..R\\p..,_I._ NUM~'i:..R PER NC,E: 4-.

/_

I I

~J 14.oB.3

14. o ='.3.01,q, REI= ______ __,-.,.

SECTION Z-Z

.:5C4Lt!E.* c,;**= 1 1-0p 7

A41 jf 2

I A,.1

! "'Jo 0

I 3~ Rc.F.

6 5

4 3

[______ __ _

__J PT Fill Poc,t,(GT WITH

/<t:CO.IVf8/NeR CATALY.5T Pe;? NOTE= 3 PR/OJ? TO

//1/6,At..lATION oF SCR'£/../

f Net.DING SE.CTION '<-'<

SCl>-l.e:.;

l'Z." ~ l'-0

I

.375Q I

-X'45-87yp ReF 5E.C "T\\ON x-x SC~LE.: \\'2": I '-o*

ROT,t,,. 1ED 135° CC W THIS :SURF4Cc NJL./S r /1/07'

.:"XTND C3£yoND J-A-1

<A--~~--< SEE A/OT£ 5 7

a

..SEE /'I/C>7'E 5 WE /IV A -A (,yp z Pt.l!:/C~-5)

5C:AC..E;:.,c:"c./(...{_

NO.

DRAWING TITLE REFERENCE DWGS 5

+

4 3

2 REVISIONS REV DESCRIPTION DATE R.E.V@. LocATION.S /v/Af?K£D to,,JB..

THI.JS ~

fh PART NO.

QUAN '

3 R.E.V, C,E.ONl(;:uuc TOI_ IN V/E.W A-A. ADDEO DATUM A 4 RE:Vi SE.D NOTE. 3 BILL OF MATERIAL DESCRIPTION C.

Z.

l;54os.3C SCl<'EEN ASSY 3

I

/15"0~578 Pt..U6 7

1 1150~44c.s~1,er NOTES:

M F

L THIS PART MUST BE FABRICATED, INSPECTED, AND CERTIFIED IN ACCORDANCE WITH THE ASME BOILER & PRESSURE VESSEL CODE, SECTION VIII 1983 EDITION, WITH NO ADDENDA.

2.

"PT"' DENOTES A LIQUID PENETRANT EXAMINATION OF THE WELD IN ACCORDANCE WITH SECTION V, ARTICLE 6 OF THE ASME BOILER & PRESSURE VESSEL CODE, 1983 EDITION WITH NO ADDENDA.

~3. RECDMBINER CATALYST SHALL BE ADDED TO FILL POCKETS IN HEAD PRIOR TO WELDING OF SCREEN ASSY. THE REQUIRED MINIMUM QUANTITY FOR EACH POCKET IS:

PT. NO. 6 - 10 : f2 GRAMS. FILL REMAINDER OF CAVITIES WITH

/IS40/8P DWG. NO.

PIN 4 (40 GRAMS-MINIMUM PER CAVITY)

THE CANISTER SERIAL NUMBER AND INLET PORT DESIGNATION SHALL BE ENGRAVED, MILLED OR WELD DEPOSIT IN THE AREA SHOWN.. THE LETTERS & DIGITS SHALL BE 1 114 :!: 1'18 INCHES HIGH.

THE SERIAL NUMBEP SHALL BE IN THE FORM "F-XXX" WHERE "XXX" DESIGNATES A CONSECUTIVE SERIES OF 3 DIGITS BEGINNING WITH 401. ( "F" DESIGNATES FILTER CANISTER}.

5.

WELD WIRE i'ER AWS 5.4 TYPE 316L OR TYPE 308L.

6.

Tf£ CATALYTIC RECIJ.1BINERS SHOULD BE PROTECTED FROM CONTACT WITH CLEANING AGENTS, PETROLEUM PRODUCTS OR OTHER CONTAMINANTS AT ALL TIMES, PRIOR TO, OR AFTER LOADING.

TOLERANCES UNLESS OTHERWISE SPECIFIED ALL TOLERANCE DEFINITIONS PER ANSI Y14.5

  • 1973 ALL DIMENSIONS ARE FOR PART TEMPERATURE OF 68°F DECIMAL DIMENSIONS

+/-.003"

+.005" +/-.005"'

+/-.010"

+/-.031"'

FRAC. DIM. MACH.

+/- 1/64" +/- 1/32" +/- 1/32" +/- 1/16" +/- 1/16"'

+/- 1/8" FRAC. DIM. UNMACH.

+/- 1/16"

+/- 1/16"

- ~

+/- 1/8"

+/- 3/16"

+/- 3 16" DIM. FOR BURNING

+/- 1/8"

_ 1/8"

+/- 1/8" 1/8'"

+/-3/16"

+/- 3/16 o.,, FLATNESS

.001'"/IN. OF SURFACE UP TO..920** MAX BREAK CORNERS z

~ PERPENDICULARITY

.002'" IN. OF SURFACE U? TO.020" MAX 1 / 64" R. MAY..

i < CONCENTRICITY

.015" DIA.

OR CHAMFER V::.

ANGULARITY

+/- 0° - 30' CHAMFER :!: 5o 1;;: ALL MACHINED SURFACES TO HAVE 250/RHR FINISH UNLESS OTHERWISE NOTED

~~~;,...u,~.,....i* F'lLTER CAN/5-YER UPPER 1-lEA.0 WE.LDMENT 2

THISORAWINGISTHEPROPERTYOF Babcock & Wilcox 11 McDtrmoU Company ANO ISLOANEOUPUN CONDITION THAT ITIS NOT TO BE R£PffOOUCEOORCOPl[OtNWHOL[OAIN PARLORUSEO fOR FURNISHING INFORMATION TO OTHERS. OH FOR "NY OTHER PURPOSE DETRIMENTAL TO THE INTEREST Of BJ.f!COCK&WILCOXANOWILLBERETURNEOUPONRE(lUEST.

DONOTSCAI.E U5f:Dl11Ef1SION5DNLY, DAAWING.N

  • PG 1087D*5 D

C B

A