Drawing 02-1154046-F, Rev. 6, Knockout Canister Head Weldment - Frame 1 of 2
ML18331A275
Person / Time
Site: 07200020
(SNM-2508)
Issue date: 04/12/1985
From:
US Dept of Energy, Idaho Operations Office, Babcock & Wilcox
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML18331A065 List: ... further results
References
CLN190271 02-1154046-F, Rev 6
Download: ML18331A275 (1)


Text

For Information Only

  • '.')

7

---1 8

7 E

c 5

...----------------~;R6P----------------

r

'$t.C1' \\O~ Z -z D

I I,

I* I *

    • 1.

A

. =l:.c,l<.~~U'.\\"C:.i:;~\\~;::~... "J!i.-~ *.. :.C.lls./'t~I~

D II *Till HI. 11.

IEFHEIEE,HU 2

1 REVISIONS RCVl91 2

4 Re.v1se.o ~oTtaa 2 5

ZWAs'l'c9 @A ~ 40 G,RAMS WA-; 10 C.RAMS IN NCTEc. 'Z.

NOTES:

l.

WELD WIRE PER AWS 5, 4 TYPE 316L OR 30HL

2.

Fn.L ~CKETS WITH RE~INER CAT.61.YST.1 THE RECIUIREO AMOUNTS IN ~CH J'OC.KET 1RE 10 _ ~/2 G.RAMS OF. PART NO. a.

~o1:~~~E~og~i':\\~~:~I~j_PART NO. 7 (A l!INIMUM

3.

THIS PART.NJST Bt PROCURED, FABRICATED, INSPECTED, ANO CERTIFIED IN 1'CCOR!)ANCE l:!ITtl 'TH.E ASME 8JIL£R & PRESSURE VESS8_ CODE,

'.. SECTION.VIn,*CD:!VISION :1.. OF THE 1983 EDITION WITH NO ADDENDA FOR A lElHAL *VESSEL.

4.

'~PT" CENOTES A. UQUIO PENETRANT INSPECTION OF THE l'F-LO IN

, ACCORDANCE lll1H ASTM E-165.

5.

THE CANISTER SERUL NlJ,IBER ANO FLOW DIRECTION SHALL BE APPUED BY ENGRAVING; MILLING OR WELD DEPOSIT IN THE AREA SHOI\\N. THE L.ETTER$"'A,N!l,DIGITS SHALL BE AT LEAST J. INCH HIGH ANO MUST BE

~~~:~ =

~K~~~~ ~~.. F~~IGN~S s~~~~ou~~:ISTER Atll ")00(" IS*i.A CONSECUTIVE.. SERIES OF 3 DIGITS BEGINNING WITH 501.

6.

THE CATACl'.TIC RECOMBINERS SHOULD l3E PROTECTED F~OM GONTACl' WITH CLEANING AGENTS, PETROLEIM PRODUCTS OR OTHER CON,4'1INANTS AT ALL TI"'S, PRIOR TO OR AFTER LOADING

  • TOLERANCES UNLESS OTHERWISE SPECIFIED ALL TOLERANCE DEFINITIONS PER ANSI Yl4.5
  • 1973 ALL DIMENSIONS ARE FOR PART TEMPERATURE OF 68°F UP TO ov;~ 6 OV~~T2"~~E:.:r~;~~~'t OVER 6" INCL. 12" INCL. 24" INCL INCL.

INCL.

1,0"

+.003"

+.005.

+.005" +/-.OTO"

+/-.031"

+/- T 64" +/- 1/32.

T/32"
t:: 1/16"
': T/16"
': 1/8"

.001"/IN. OF SURFACE UP TO.020" MAX BREAK CORNERS

.002" IN. OF SURFACE UP TO.020" MAX T/6'" R. MIN E

C i C C NCENTRICITY I 5" DI....

OR CHAMFER

~~ ;~G:!~~:~YEO SURF;C~~ -T~o~AVE 2!>>0/RHR FINISH UNLESS ~~~~:~s: !~TED A P"""~~;;:i':-4 K~oc.\\<.. rnrraf.\\\\S1t

~'t..~Q W£.Lt:>M£.~\\° DWG ND.

"'=oo===*=._.=,... =c,.o;;;;;;,.-;;;:;.,;;;;;=,:-r::::se::-=*LE~\\ '.:--;\\---,------, \\ \\ ~4,Q4G, F /c>

e J

--~----------- 0