ML18330A141

From kanterella
Jump to navigation Jump to search
Relief Request Number RR 5-7, Proposed Alternative to ASME Section XI Code Requirements for Repair of Reactor Pressure Vessel Head Penetrations
Date released: 12/04/2018 Download: ML18330A141



Framatome, Document No. 51-9292503, Palisades CRDM & Ici Nozzle Idtb Repair - Life Assessment Summary
ML18330A146
Person / Time
Site: Palisades 
Issue date: 11/24/2018
From: Fyfitch S, Haibach B, Hosler R, Straka T, Wiger T
Framatome
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
PNP 2018-054
Download: ML18330A146 (16)
Framatome, Inc. Affidavit Supporting
ML18330A145
Person / Time
Site: Palisades 
Issue date: 11/20/2018
From: Opsal P
Framatome
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
PNP 2018-054
Download: ML18330A145 (4)
Relief Request Number RR 5-7, Proposed Alternative to ASME Section XI Code Requirements for Repair of Reactor Pressure Vessel Head Penetrations
ML18330A143
Person / Time
Site: Palisades 
Issue date: 11/26/2018
From:
Entergy Nuclear Operations
To:
Office of Nuclear Reactor Regulation
References
PNP 2018-054
Download: ML18330A143 (32)
Relief Request Number RR 5-7, Proposed Alternative to ASME Section XI Code Requirements for Repair of Reactor Pressure Vessel Head Penetrations
ML18330A142
Person / Time
Site: Palisades 
Issue date: 11/26/2018
From: Halter M
Entergy Nuclear Operations
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
PNP 2-18-054
Download: ML18330A142 (2)