ML18299A083

From kanterella
Jump to navigation Jump to search

NRC Disposition of TSTF Comments on the Draft Safety Evaluation of TSTF-564, Safety Limit MCPR
ML18299A083
Person / Time
Site: Technical Specifications Task Force
Issue date: 11/16/2018
From: Victor Cusumano
Office of Nuclear Reactor Regulation
To:
Technical Specifications Task Force
Honcharik M
Shared Package
ML18299A048 List:
References
CAC MG0161, EPID L-2017-PMP-0007, TSTF-564 PROJ0753
Download: ML18299A083 (2)


Text

Enclosure 3 NRC DISPOSITION OF TSTF COMMENTS ON THE DRAFT SAFETY EVALUATIONS OF TSTF-564, SAFETY LIMIT MCPR General TSTF Comments from Attachment 1 to TSTF letter dated October 24, 2018 (ADAMS Accession No. ML18297A361).

The TSTF identified additional minor changes to TSTF-564, Revision 1, following its submittal.

These changes reflect a modification of the rounding methodology incorporated in Revision 1.

The Safety Limit for Global Nuclear Fuel (GNF) GE14 fuel is revised from 1.05 to 1.06 and the referenced GNF methodology document is updated. These changes have been previously discussed with the NRC staff. Revision 2 of TSTF-564 is enclosed.

Disposition of Comments on the Draft Traveler Safety Evaluation of TSTF-564 Page(s)

Line(s)1 TSTF Comment on Traveler SE NRC Disposition 1

20 The term technical specifications should be revised to be plural to be consistent with 10 CFR 50.36 and the Standard Technical Specifications (STS).

Incorporated.

1 34-35 For completeness, we recommend adding a reference to the Revision 0 submittal of TSTF-564.

Incorporated.

1 36 Editorial suggestion. There was only one request for additional information.

Incorporated.

Disposition of Comments on the Draft Model Safety Evaluation of TSTF-564 Page(s) Line(s)2 TSTF Comment on Model SE NRC Disposition 3

31-34 Recommend placing the description of the current TS 2.1.1.2 in brackets and in bold to accommodate various plant TS without invoking a variation from the SE.

Incorporated.

4 14-16 Recommend placing the description of the current TS 2.1.1.2 in brackets and in bold to accommodate various plant TS without invoking a variation from the SE.

Incorporated.

9 12 For clarity, the SE should state that the MCPR99.9% value will be included in the COLR instead of the MCPR value.

Incorporated.

1 Line numbers correspond to the proposed revisions attached to TSTF letter dated October 24, 2018 (ADAMS Accession No. ML18297A361).

2 Line numbers correspond to the proposed revisions attached to TSTF letter dated October 24, 2018 (ADAMS Accession No. ML18297A361).