Subject:
Transmittal of EPRI Report 3002013039 "EPRI MOV Performance Prediction Program: Addendum 10 to EPRI 103237-R2: PPM Version 4.0 Software Changes" Project Number: 689
Dear Mr. Holonich:
Enclosed are five (5) paper copies of the report "EPRI MOV Performance Prediction Program: Addendum 10 to EPRI 103237-R2: PPM Version 4.0 Software Changes," EPRI Technical Report 3002013039.
The purpose of this letter is to request NRC review to facilitate an NRC Staff Evaluation leading to a determination that the PPM version 4.0 software is acceptable for referencing in licensing applications and that an updated Safety Evaluation is not required.
The EPRI motor operated valve (MOV) Performance Prediction Methodology (PPM) software was developed to enhance industry's ability to size MOVs and predict their performance. Versions 1.0 - 3.3 were approved by the NRC through a Safety Evaluation and four (4) supplements. The most recent versions of the software (versions 3.4 and 3.5) submitted to the staff were reviewed and approved by NRC by letter on April 2, 2015.
Since that time, Version 4.0 has been completed. The attached report documents the changes made to the EPRI PPM software between version 3.5 and version 4.0. For reference, Table 1 provides a summary of all EPRI MOV Performance Prediction Program submittals and NRC approvals to date.
The primary changes to the PPM software between version 3.5 and version 4.0 were 1) to make it compatible with 64-bit operating systems and 2) to correct coding errors without changing functionality. In addition, the "Improved Gate Valve Un-Wedging Method" documented in EPRI report 1020350 "EPRI MOV Performance Prediction Program - Addendum 3 to TR-103237-R2: An Improved and Validated Gate Valve Un-wedging Methodology-A," dated March 2010, was incorporated into the PPM version 4.0 software. This hand calculational methodology was previously approved by NRC in Supplement 4 to the NRC SE on TR-
. 103237-Rl, "EPRI MOV Performance Prediction Program Topical Report dated February 24, 2009.
Please note that the enclosed report contains proprietary information. All proprietary information is NUCLEAR. CLEAN AIR ENERGY
Joseph Holonich Jr August 30, 2018 Page 2 highlighted with yellow shading indicating that information is considered trade secrets in accordance with 10CFR2.390. A letter requesting that the report be withheld from public disclosure and an affidavit describing the basis for withholding this information are provided as Attachment 1.
Two paper copies of the non-proprietary report "EPRI MOV Performance Prediction Program: Addendum 10 to EPRI 103237-R2: PPM Version 4.0 Software Changes NP," Technical Report 3002013039NP, are also enclosed. This non-proprietary report is identical to the enclosed proprietary report except that the proprietary information has been deleted and the letters "NP" appear in the BWRVIP report title and report number.
All NRC fees will be paid directly by EPRI and all bills should be sent to the following address:
EPRI Attention: Accounts Payable Dept.
3420 Hillview Avenue PO Box 10412 Palo Alto, CA 94304 If there are any questions on these matters, please contact me (202-739-8037), txr@nei.org or Mr. John Hosler (704-252-0780), JHOSLER@epri.com.
Sincerely, Timothy Riti Attachment C:
Mr. Joseph Holonich Jr., NRR/DPR/PLPB, NRC Mr. Michael Farnan, NRR/DF/EPNB, NRC (w/o enclosures)
Mr. John Hosler, EPRI (w/o enclosures)
Mr. James Heishman EPRI (w/o enclosures)
Mr. Thomas Walker, EPRI (w/o enclosures)
Joseph Holonich Jr August 30, 2018 Page 3 Table 1 Summary of EPRI MOV Performance Prediction Program Submittals and NRC Approvals EPRI/NEI Submittal EPRI Report #
EPRI Product(s)
NRCSE/SE Description Supplement/Evaluation EPRI MOV Performance TR-103237-Rl PPM version 1.0 software NRC SE on TR-103238-Rl Prediction Program Topical and Westinghouse, March 15, 1996 Report Revision 1, dated Anchor/Darling Double November 1995.
disk gate valve hand calculation methods NRC approved EPRI MOV TR-103237-R2 PPM version 1.0 software NRC SE on TR-103237-Rl, Performance Prediction and Westinghouse, Supplement 1, February 20, Program Topical Report Anchor/Darling Double disk 1997 Revision 2, dated April 1997.
gate valve, Aloyco and WKM valve hand calculation methods NRC approved Addendum 1 AD-110778 PPM version 2.0 software NRC SE on TR-103237-Rl, to TR103237-R2, dated changes Supplement 2, April 20, December 1998.
2001 NRC approved Addendum 2 to 1003279 Thrust Uncertainty NRC SE on TR-103237-Rl, TR-103237-R2, dated October Method (Hand calculation)
Supplement 3, September 2002.
30,2001 NRC approved Addendum 3 to 1020350 Improved Gate Valve Un-NRC SE on TR-103237-Rl, TR-103237-R2-A, dated March wedging Method (Hand Supplement 4, February 24, 2010.
calculation) 2009 NRC approved Addendum 4 to 1020357 Use of Static TR-103237-R2-A, dated March Closure Data for Un-2010.
Wedging Calculations (Hand calculation)
NRC approved Addendum 5 to 1020358 PPM version 3.1 software TR-103237-R2-A, dated March changes 2010.
NRC approved Addendum 6 to 1020359 PPM version 3.2 software TR-103237-R2-A, dated March changes 2010.
NRC approved Addendum 7 to 1020360 PPM version 3.3 software TR-103237-R2-A, dated March changes 2010.
NRC approved Addendum 8 to 3002007058 PPM version 3.4 software NRC Staff Evaluation of PPM TR-103237-R2-A, dated March changes v 3.4 and 3.5, April 2, 2015 2016.
NRC approved Addendum 9 to 3002007059 PPM version 3.5 software TR-103237-R2-A, dated March changes 2016.
Addendum 10 to TR-103237-3002013039 PPM version 4.0 software R2, dated April 2018.
changes
~r.=l~, 1 ELECTRIC POWER
. a=l-11..
RESEARCH INSTITUTE Ref. EPRI Docket No. 689 Date
~~
~ c;tO/(
Attention: Joseph Holonich Jr.
Document Control Desk Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, DC 20555-0001
Subject:
Request for Withholding of the following Proprietary information included in:
NEIL WILMSHURST Vice President and Chief Nuclear Officer EPRI MOV Performance Prediction Program, Addendum 10 to EPRI TR-103237-R2: PPM Version 4.0 Software Changes, EPRI Technical Report 3002013039 To Whom It May Concern:
This is a request under 10 C.F.R. §2.390(a)(4} that the U.S. Nuclear Regulatory Commission eNRC"}
withhold from public disclosure the information identified in the enclosed Affidavit consisting of the proprietary information owned by Electric Power Research Institute, Inc. ("EPRI") identified above (the "Report"). Proprietary and non-proprietary versions of the Report and the Affidavit in support of this request are enclosed.
EPRI desires to disclose the Report in confidence as a means of exchanging technical information with the NRC. The Report is not to be divulged to anyone outside of the NRC or to any of its contractors, nor shall any copies be made of the Report provided herein. EPRI welcomes any discussions and/or questions relating to the information enclosed.
If you have any questions about the legal aspects of this request for withholding, please do not hesitate to contact me at {704) 595-2732. Questions on the content of the Report should be directed to Jim Heishman of EPRI at {704) 595-2768.
Sincerely,
~Ll~
Attachment( s)
Together... Shaping the Future of Electricity 1300 West W.T. Harris Boulevard, Charlotte, NC 28262*8550 USA* 704.595.2732
- Mobile 704.490.2653
- nwilmshursl@epri.com
~~~11 ELECTRIC POWER t=l-1~
RESEARCH INSTITUTE AFFIDAVIT RE:
Request for Withholding of the Following Proprietary Document:
EPRI MOV Performance Prediction Program, Addendum 10 to EPRI TR-103237-R2: PPM Version 4.0 Software Changes, EPRI Technical Report 3002013039 I, Neil Wilmshurst, being duly sworn, depose and state as follows:
I am the Vice President and Chief Nuclear Officer at Electric Power Research Institute, Inc. whose principal office is located at 3420 Hillview Avenue, Palo Alto, California {"EPRI") and l have been specifically delegated responsibility for the above-listed Report that is sought under this Affidavit to be withheld (the "Report"). I am authorized to apply to the U.S. Nuclear Regulatory Commission ("NRC") for the withholding of the Report on behalf of EPRI.
- EPRI Proprietary Information is identified in the above referenced report with highlighted yellow shading. The pages with the proprietary information are also marked with the letters "TS" indicating that information is considered trade secrets in accordance with 10 CFR 2.390.
EPRI requests that the Report be withheld from the public on the following bases:
Withholding Based Upon Privileged And Confidential Trade Secrets Or Commercial Or Financial Information (see e.g. 10 C.F.R. §2.390(a)(4})::
- a.
The Report is owned by EPRI and has been held in confidence by EPRI. All entities accepting copies of the Report do so subject to written agreements imposing an obligation upon the recipient to maintain the confidentiality of the Report. The Report is disclosed only to parties who agree, in writing, to preserve the confidentiality thereof.
- b.
EPRI considers the Report and the proprietary information contained therein (the "Proprietary Information") to constitute trade secrets of EPRI.
As such, EPRI holds the Report in confidence and disclosure thereof is strictly limited to individuals and entities who have agreed, in writing, to maintain the confidentiality of the Report. EPRI made a substantial economic investment to develop the Report, and, by prohibiting public disclosure, EPRI derives an economic benefit in the form of licensing royalties and other additional fees from the confidential nature of the Report. If the Report and the Proprietary Information were publicly available to consultants and/or other businesses providing services in the electric and/or nuclear power industry, they would be able to use the Report for their own commercial benefit and profit and without expending the substantial economic resources required of EPRI to develop the Report.
- c.
EPRl's classification of the Report and the Proprietary Information as trade secrets is justified by the Uniform Trade Secrets Act which California adopted in 1984 and a version of which has been adopted by over forty states. The California Uniform Trade Secrets Act, California Civil Code §§3426 - 3426.11, defines a "trade secret" as follows:
"'Trade secret' means information, including a formula, pattern, compilation, program device, method, technique, or process, that:
(1) Derives independent economic value, actual or potential, from not being generally known to the public or to other persons who can obtain economic value from its disclosure or use; and (2) Is the subject of efforts that are reasonable under the circumstances to maintain its secrecy."
- d.
The Report and the Proprietary Information contained therein are not generally known or available to the public. EPRI developed the Report only after making a determination that the Proprietary Information was not av~ilable from public sources. EPRI made a substantial investment of both money and employee hours in the development of the Report.
EPRI was required to devote these resources and effort to derive the Proprietary Information and the Report. As a result of such effort and cost, both in terms of dollars spent and dedicated employee time, the Report is highly valuable to EPRI.
- e.
A public disclosure of the Proprietary Information would be highly likely to cause substantial harm to EPRl's competitive position and the ability of EPRI to license the Proprietary Information both domestically and internationally. The Proprietary Information and Report can only be acquired and/or duplicated by others using an equivalent investment of time and effort.
I have read the foregoing and the matters stated herein are true and correct to the best of my knowledge, information and belief. I make this affidavit under penalty of perjury under the laws of the United States of America and under the laws of the State of California.
Executed at 1300 W WT Harris Blvd, Charlotte, NC being the premises and place of business of Electric Power Research Institute, Inc.
Neil Wilmshurst (State of North Carolina)
(County of Mecklenburg)
Subscribed and SI.Yorn to (or affirmed) before me on this May of ~
, 2018, by 7'l!il 4lifMA~'t:
, proved to me on the basis of satis tofyevidence to be the person(s} who appeared before (!18.
Signature {lMµ N. -,R_OIP(
My Commission Expires )._ m/ay of ~
(Seal)
I I I II 1*,,
'.-.t..HH i '-" o~* * ~o ',
..,.. ~
v~"..
.. Q
~-
NOTARY PUBLIC
, 20!!!,
CABARRUS COUNTY
...A.
',*yo
~'t':~
11,~r:,..cARO~~.... '
I IN,I I
l r="~12, 1 ELECTRIC POWER
-.=1-RESEARCH INSTITUTE EPRI MOV Performance Prediction.Program Addendum 10 to EPRI TR--103237--R2: PPM Version 4.0 Software Changes Np
'.PREPARED UNDER THE
- PROGRAM 2018 TECHNICAL REPORT
- ~**.
NOTICE: THIS REPORT CONTAINS THE NON-PROPRIETARY INFORMATIGN THAT IS INCLUDED*IN THE PROPRIETARY VERSION OF.THEREPORT. THE PROPRIETARY VERSION'CONTAINS PROPRIETARY iNFORMATION THAT IS THE NTELLECTUAL PROPERTY OF BWRVIP UTILITY MEMBERS AND EPRI. ACCORDINGLY, _IT IS AVAILABLE ONLY UNDER LICENSE FROM EPRI AN.D MAY NOT BE REPRODUCED OR DISCLOSED, WHOLLY OR IN PART, BY ANY LICENSEE TO ANY OTHER PERSON OR
- ORGANIZATION WITHOUT EPRl'S PRIOR WRITIEN CONSENT, EXCEPT AS MAY BE ALLOWED UNDER THE TERMS AND CONDITIONS OF THE APPLICABLE LICENSE
_;_***-*--""* *;...;.*'*-***---------------~---GBEEMEID
__ \\IYJil:LfE81-----,----'--------------'
EPRI MOV Performance Prediction Program Addendum 10 to EPRI TR-103237-R2: PPM Version 4.0 Software ChangesNP 3002013039NP Final Report, April 2018 EPRI Project Manager.
J. Hosler All or a portion of the requirements of the EPRI Nuclear Quality Assurance Program apply to this product.
'NO ELECTRIC POWER RESEARCH INSTITUTE 3420 Hillview Avenue, Palo Alto, California 94304-1338
- PO Box 10412, Palo Alto, California 94303-0813
- USA 800.313.3774
- 650.855.2121
- askepri@epri.com
- www.epri.com
DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITIES THIS DOCUMENT WAS PREPARED BY THE ORGANIZATION NAMED BELOW AS AN ACCOUNT OF WORK SPONSORED OR COSPONSORED BY THE ELECTRIC POWER RESEARCH INSTITUTE, INC. (EPRI). NEITHER EPRI, ANY MEMBER OF EPRI, ANY COSPONSOR, THE ORGANIZATION BELOW, NOR ANY PERSON ACTING ON BEHALF OF ANY OF THEM:
(A) MAKES ANY WARRANTY OR REPRESENTATION WHATSOEVER, EXPRESS OR IMPLIED, (I)
WITH RESPECT TO THE USE OF ANY INFORMATION, APPARATUS, METHOD, PROCESS, OR SIMILAR ITEM DISCLOSED IN THIS DOCUMENT, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, OR (II) THAT SUCH USE DOES NOT INFRINGE ON OR INTERFERE WITH PRIVATELY OWNED RIGHTS, INCLUDING ANY PARTY'S INTELLECTUAL PROPERTY, OR (Ill) THAT THIS DOCUMENT IS SUITABLE TO ANY PARTICULAR USER'S CIRCUMSTANCE; OR (8) ASSUMES RESPONSIBILITY FOR ANY DAMAGES OR OTHER LIABILITY WHATSOEVER (INCLUDING ANY CONSEQUENTIAL DAMAGES, EVEN IF EPRI OR ANY EPRI REPRESENTATIVE HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES) RESULTING FROM YOUR SELECTION OR USE OF THIS DOCUMENT OR ANY INFORMATION, APPARATUS, METHOD, PROCESS, OR SIMILAR ITEM DISCLOSED IN THIS DOCUMENT.
REFERENCE HEREIN TO ANY SPECIFIC COMMERCIAL PRODUCT, PROCESS, OR SERVICE BY ITS TRADE NAME, TRADEMARK, MANUFACTURER, OR OTHERWISE, DOES NOT NECESSARILY CONSTITUTE OR IMPLY ITS ENDORSEMENT, RECOMMENDATION, OR FAVORING BY EPRI.
THE FOLLOWING ORGANIZATION, UNDER CONTRACT TO EPRI, PREPARED THIS REPORT:
MPR Associates, Inc.
NOTICE: THIS REPORT CONTAINS THE NON-PROPRIETARY INFORMATION THAT IS INCLUDED IN THE PROPRIETARY VERSION OF THE REPORT.
THE PROPRIETARY VERSION CONTAINS PROPRIETARY INFORMATION THAT IS THE NTELLECTUAL PROPERTY OF BWRVIP UTILITY MEMBERS AND EPRI.
ACCORDINGLY, IT IS AVAILABLE ONLY UNDER LICENSE FROM EPRI AND MAY. NOT BE REPRODUCED OR DISCLOSED, WHOLLY OR iN PART, BY ANY LICENSEE TO ANY OTHER PERSON OR ORGANIZATION WITHOUT EPRl'S PRIOR WRITIEN CONSENT, EXCEPT AS MAY BE ALLOWED UNDER THE TERMS AND CONDITIONS OF THE APPLICABLE LICENSE AGREEMENT WITH EPRI.
THE TECHNICAL CONTENTS OF THIS PRODUCT WERE PREPARED IN ACCORDANCE WITH THE EPRI QUALITY PROGRAM MANUAL THAT FULFILLS THE REQUIREMENTS OF 10 CFR 50 APPENDIX 8. THIS PRODUCT IS SUBJECT TO THE REQUIREMENTS OF 10 CFR PART 21.
CERTIFICATION'OF CONFORMANCE CAN BE; OBTAINED FROM EPRI.
NOTE For further information about EPRI, call the EPRI Customer Assistance Center at 800.313.3774 or e-mail askepri@epri.com.
Electric Power Research Institute, EPRI, and TOGETHER... SHAPING THE FUTURE OF ELECTRICITY are registered service marks of the Electric Power Research Institute, Inc.
Copyright© 2018 Electric Power Research Institute, Inc. All rights reserved.
ACKNOWLEDGMENTS The following organizations, under contract to the Electric Power Research Institute (EPRI),
prepared this report:
MPR Associates, Inc.
320 King Street Alexandria, VA 22314 Principal Investigators J. Gratz C. Rice W. Smith J. Simons T. Shaw P. Knittle This report describes research sponsored by EPRI.
This publication is a corporate document that should be cited in the literature in the following manner:
EPRI MOV Performance Prediction Program: Addendum 10 to EPRI TR-103237-R2-PPM Version 4.0 Software Changes. EPRI, Palo Alto, CA: 2018. 3002013039.
111
ABSTRACT This addendum to EPRI report TR-103237-R2, EPRI MOV Performance Prediction Program Topical Report, documents changes made to the EPRI Motor-Operated Valve (MOV)
Performance Prediction Methodology (PPM) computer code between Version 3.5 and Version 4.0.
The EPRI MOV PPM is a validated computer code for determining the required thrust or torque to stroke gate, globe, and butterfly valves under design basis conditions. Version 1.0 of the PPM computer code was issued in 1995. EPRI MOV Performance Prediction Program Topical Report, Revision 1 (TR-103237-Rl) documents a technical description of Version 1.0, including model data comparisons justifying the method. The Nuclear Regulatory Commission (NRC) issued a safety evaluation on Version 1.0 in March 1996 and issued a supplemental safety evaluation covering specific hand calculation methods in February 1997. EPRI MOV Performance Prediction Program Topical Report, Revision 2 (TR-103237-R2) was issued in April 1997 and includes the hand calculation methods as well as the initial NRC safety evaluation and supplemental safety evaluations.
Version 2.0 of the PPM computer code was issued in August 1998 to correct minor software errors and incorporate features to facilitate implementation. Addendum 1 to EPRI TR-103237-R2 (AD-110778) describes the changes between Version 1.0 and Version 2.0 and demonstrates that the changes did not affect the code's ability to make bounding predictions ofrequired thrust and torque. The NRC issued a safety evaluation covering Version 2.0 in May 2000.
Version 3.0 was issued in August 2001. It incorporated a Windows-based user interface model (WUIM) and automated many of the hand calculations that had previously been required.
Version 3.0 was recalled shortly thereafter, due to the discovery of a coding error. Version 3.1 corrected the error and was issued in November 2001. Addendum 5 to EPRI TR-103237-R2 (1020358) describes the changes from Version 2.0 to Version 3.1. This addendum includes the NRC Safety Evaluation for Version 3.1.
Version 3.2 was issued in December 2003 to correct minor errors in the software and incorporate a design change related to butterfly valve torque predictions. Addendum 6 to EPRI TR-103237-R2 (1020359) describes the changes from Version 3.1 to Version 3.2. This addendum includes the NRC Safety Evaluation for Version 3.2.
V
Version 3.3 of the PPM was issued in August 2005 to incorporate changes to the WUIM that addressed several errors and added new features artd functionality to the user interface.
Addendum 7 to EPRI TR-103237-R2(1020360) describes the changes from Version 3.2 to Version 3.3. This addendum includes the NRC Safety Evaluation for Version 3.3.
Version 3.4 addressed several software error and information notices, improved the accuracy of PPM predictions ( differential pressures), and provided new functionality in the user interface, Addendum 8 to EPRI TR-103237-R2 (3002007058) describes the changes from Version 3.3 to Version 3.4. This addendum includes a letter from the NRC accepting Version 3.4.
Version 3.5 addressed several problem reports and error notices and incorporated SI Units.
Addendum 9 to EPRI TR-103237-R2 (3002007059) describes the changes from Version 3A to Version 3.5. This addendum includes a letter from the NRC accepting Version 3.5.
Keywords Motor..,operated valves Performance Software tools Valves Vl
er=-121 ELECTRIC POWER RESEARCH I NSTlTUTIE EXECUTIVE
SUMMARY
Deliverable Number: 3002013039NP Product Type: Technical Report Product
Title:
EPRI MOV Performance Prediction Program: Addendum 10 to EPRI TR-103237-R2: PPM Version 4.0 Software ChangesNP PRIMARY AUDIENCE: Plant staff responsible for engineering evaluation of valve thrust and torque requirements SECONDARY AUDIENCE: Plant engineering staff KEY RESEARCH QUESTION There is a need for validated analytical methods for predicting thrust and torque requirements for nuclear plant gate, globe, and butterfly valves.
RESEARCH OVERVIEW As part of the EPRI MOV Performance Prediction Program (PPP), improved methodologies for analyzing gate, globe, and butterfly valves were developed and implemented in the form of a computer program called the Performance Prediction Methodology (PPM). In Versions 1.0 and 2.0 of the PPM, valve type-specific technical modules were combined with a DOS-based user interface module (UIM). The UIM provided an interface with the user and ensured that the various technical modules were run properly. In Version 3 of the PPM (PPM for Windows), a Windows-based user interface module (WUIM) was developed to interface with the user and execute the technical modules. This updated version of the software also performed many of the calculations that users were previously required to perform by hand. Although Versions 1.0 and 2.0 of the PPM were only applicable to MOVs, Version 3 was adapted to also cover air operated valves (AOVs) and hydraulically operated valves (HOVs).. The latest version of the PPM software, Version 4.0, was developed to provide compatibility with 64-bit operating systems, add the EPRI Refined Gate Valve Unwedging Methodology, and correct several issues identified in problem reports and information or error notices.
KEY FINDINGS Key changes incorporated in Version 4.0 of the PPM are summarized below:
Recode and recompile the four (4) PPM technical modules (SFM, GLBM, GATM, and BFM) in ANSI G,. to provide compatibility with 64-bit operating systems (and maintain compatibility with 32-bit operating systems)
Upda'te the gate valve applicability table in the WUIM to address Information Notice 2014-01 Revise the globe valve prediction report to address missing reference numbers as detailed in Problem Report 2014-02 Revise the software to address errors experienced wheri modeling restrictors, as described in Error Notice 2015'-01 Add the Refined EPRI Unwedging Method as detailed in Addendum 3 to TR-103237-R2 Revise the software to address an error in the SFM module related to modeling two-phase flow scenarios to address Error Notice 2017-01 Vll
ELECTRIC POV\\r'ER RESEARCH INSTITUTE EXECUTIVE
SUMMARY
Revise the software to correct gate valve model dimensional checks as described in Problem Report 2017-02 Revise the software to correct the globe valve model orientation check (pitch and roll angles) as described in Problem Report 2017-03 Revise the User Manual to clarify use of the Equivalent Resistance Method and Full System Flow Meth_od in the gate valve model as described in Problem Report 2017-04 Revise the software to correctly display the piping labels in the Gate Valve user interface (Pipe Data Tab) as described in Problem Report 2017-05, Rev. 1 Revise the software to correct the modal/non-modal window error as described in Problem Report 2018-01 Revise the software and User Manual to change "English Units" to "US Customary Units" WHY THIS MATTERS This software development project has produced a version of the PPM software that is compatible with 64-bit operating systems. Accordingly, the software will remain a viable tool for use in defining operational load (thrust/torque) requirements for gate, globe, and butterfly valves well into the future.
HOW TO APPLY RES UL TS The PPM version 4.0 software may be used to predict thrust and torque requirements for gate, globe, and butterfly valves.
LEARNING AND ENGAGEMENT OPPORTUNITiES EPRI MOV PPM User Group EPRI CONTACTS: John Hosler (jhosler@epri.com) and Thomas Walker (twalker@epri.com)
PROGRAM: Nuclear Maintenance Applications Center, P41.05.01 IMPLEMENTATION CATEGORY: Category 1 Together... Shaping the Future of Electricity Electric Power Research Institute 3420 Hillview Avenue, Palo Alto, California 94304-1338
- PO Box 10412, Palo Alto, California 94303-0813 USA 800.313.3774
- 650.855.2121
- askepri@epri.com
- www.epri.com
© 2017 Electric Power-Research Institute (EPRI), Inc. All rights reserved. Electric Power Research Institute, EPRI, and TOGETHER... SHAPING THE FUTURE OF ELECTRICITY are registered service marks of the Electric Power Research Institute, Inc.
CONTENTS ABSTRACT.................................................................................................................................. V EXECUTIVE
SUMMARY
......................................................................... ;................. ;................ VII 1 BACKGROUND/PURPOSE................................................................................................... 1-1 Background........................................................................................................................... 1-1 Purpose.................................. :.............................................................................................. 1-2 2
SUMMARY
OF CHANGES IN VERSION 4.0......................................................................... 2-1 Software Usability lmprovements................................... ;***********************:******************************2~1 Re-code Technical Modules for Compatibility with 64-bit Operating Systems................. 2-1 Incorporate EPRI Refined Gate Valve Unwedging Methodology..................................... 2-2 Software Issue/Error Corrections.......................................................................................... 2-2 Information Notice 2014-1: Gate Valve Applicability Table............................................. 2-2 Problem Report 2014.,.02: Missing Reference Numbers in Globe Valve Prediction Report............................................................................................................................... 2-2 Error Notice 2015-01: Restrictor Modeling...................................................................... 2-3 Error Notice 2017-01: SFM modeling of Two-Phase Flow Scenarios............................. 2~3 Problem Report 2017-02: Gate Valve Model Dimensional Checks................................. 2-3 Problem Report 2017-03: Globe Valve Model Orientation Check................................... 2-3 Problem Report 2017-04: Clarify Use of ERM vs. Full SFM............................................ 2-4 Problem Report 2017-05, Rev. 1: WUIM Gate Valve Piping Labels............................... 2-4 Problem Report 2018-01: Modal I Non-inodal Window Error.......,.................................. 2-4 EPRI Code Revision Request: Change "English Units" to "US Customary Units"........... 2-4 3 CONCLUSIONS...... _................................ ;.............................................................................. 3-1 4 REFERENCES............................................................................................................ :.......... 4-1 A PPM PROBLEM REPORTS, INFORMATION NOTICES, AND ERROR NOTICES............ A-1 IX
1 BACKGROUNruPURPOSE
Background
The EPRl MOV Performance Prediction Methodology (PPM) is a validated computer code for determining the required thrust or torque to stroke gate, globe, and butterfly valves under design basis conditions. Version 1.0 of the PPM cQrnputer code was issued in 1995. EPRI MOV PerformancePrediction Program Topical Report, Revision 1 (TR-103237.,.Rl) documents a technical description of Version 1.0, including model data comparisons justifying the method.
The Nuclear Regulatory Commission (NRC) issued a safety evaluation on Version 1.0 in March 1996 and issued a supplemental safety evaluation covering specific hand calculation methods in February 1997. EPRI.MOV Performance Prediction Program Topical Report, Revision 2 (TR-103237-R2) was issued in April 1997 and includes the hand calculation methods as well as the initial NRC safety evaluation and supplemental safety evaluations.
Version 2.0 of the PPM computer code was issued in August 1998 to correct minor software errors and incorporate features to facilitate implementation. Addendum 1 to EPRI TR-103237-R2 (AD-110778) describes the changes between Version 1.0 and Version 2.0 and demonstrates that the changes did not affect the*code's ability to make bounding predictions of reqµired thrust and torque. The NRC issued a safety evaluation covering Version 2.0 in May 2000.
Version 3.0 was issued in August 2001. It incorporated a Windows-based user interface model (WUIM) and automated many of the hand calculations that had previously been required.
Version 3.0 was recalled shortly thereafter, due fo the discovery of a coding error. Version 3.1 corrected the ei:ror and was issued in November 2001. Addendum 5 to EPRJ TR-103237-R2 (1020358) describes the changes from Version 2.0 to Version 3.1. This addendum includes the NRC Safety Evaluation forVersion:3.1.
Version 3.2 was issued in December 2003 to correct minor errors in the software and incorporate a design change related to butterfly valve torque predictions. Addendum 6 to EPRI TR-103237-R2 (1020359) describes the changes from Version3.l to Version 3.2. This addendum includes the NRC Safety Evaluation for Version 3.2.
Vers1on3.3 of the PPM was issued in August 2005 to incorporate changes to the WUIM that addressed several errors and added new features and functionality to the user interface.
- Addenduin.7 to EPRITR:-l03237-R2 (1020360) describes the changes from Version 3.2 to Version 3.3. Thi.s addendum includes the NRC Safety Evaluation for Version_ 3.3.
Version 3.4 addressed several software error and information notices, improved the accuracy of PPM predictions ( differential pressures), and provided new functionality inthe user interface.
Adqendum 8 to EPRI TR:-103237-R2 (3002007058) describes the changes from Version 3.3 to Version 3.4. This addendum includes a letter from the NRC accepting Version 3.4.
1-1
Background/Purpose Version 3.5 addressed several problem reports and error notices and incorporated SI Units.
Addendum 9 toEPRI TR-103237-R2 (3002007059) describes the changes from Version 3.4 to Version 3.5. This addendum includes a letter from the NRC accepting Version 3.5.
Purpose The purpose of this report is to describe the changes made from Version 3.5 to Version 4.0 of the PPM and justify that these changes do not affect the code's ability to appropriately bound expected thrust/torque requirements for gate, globe, and butterfly valves.
The changes incorporated in Version 4.0 of the PPM are summarized below:
1-2 Recode and recompile the four (4) PPM technical modules (SFM, GLBM, GATM, and BFM) in ANSI C, to provide compatibility with both 32 and 64;..bit operating systems Add the EPRI Refined Gate Valve Unwedging Methodology as detailed in Addendum 3 to TR-103237-R2 (Reference 1)
Update the gate valve applicability table in the WUIM to address Information Notice 2014-01 (Reference 2)
Revise the globe valve prediction report to address missing reference numbers as detailed in Problem Report 2014-02 (Reference 2)
Revise the software to address errors experienced when modeling restrictors, as described in Error Notice 2015.,0l (Reference 2)
Revise the software to address an error in the SFM module related to modeling two-phase flow scenarios to address Error Notice 2017-01 (Reference 2)
Revise the software to correct gate valve model dimensional checks as described in Problem Report 2017-02 (Reference 2)
Revise the software to correct the globe valve model orientation check (pitch and roll angles) as described in Problem Report 2017-03 (Reference 2)
Revise the User Manual to clarify use of the Equivalent Resistance Method and Full System Flow Method in the gate valve model as described in Problem Report 2017-04 (Reference 2)
Background/Purpose Revise the software to correctly display the piping labels in the G~te Valve user interface (Pipe Data Tab) as described in Problem Report2017-05, Rev. 1 (Reference 2)
- Revise the software to correct the modal/non-modal window error as described in Problem Report 2018-01 (Reference 2)
Revise the software and l.Iser Manual to change "English Units" to "US Customary Units" 1-3
2
SUMMARY
OF CHANGES IN *VERSION 4.0 This section describes.the changes between PPM Version 3.5 and Version 4:o. These code revisions were performed to improve the usability of the PPM software and correct issues and/or errors identi:fiedsince development of Version 3.5.
Software Usability Improvements Re.,code Technical Modules for Compatibility with 64-bit Operating Systems The initial PPM Software (Version 1.0) was developed in 1994. The software c.onsisted of four DOS-based technical modules and a DOS user-interface module a,s listed below.
System Flow Module (SFM)
Globe Valve Module (GLBM)
Butterfly Valve Module (BFM)
Gate Valve Module (GATM)
User Interface Module (UIM)
In 2001, EPRI developed a Windows~based UIM for the PPM. Versions 3.1 through 3.5 of PPM included this Windows-based UIM but retained the four DOS-:-based technical modules (SFM, GLBM, BFM, and GATM).
The four DOS-based technical modules were originally programmed and compiled into executable files using Microsoft QuickBasic 4.5. These executable files are compatible with Microsoft Operating Systems up to 32-bit but are not compatible with the latesfMicrosoft 64-bit environments. (Note: The Windows user interface module, developed in 2001, is compatible with Microsoft 64-bit environments.)
For PPM Version 4;0, the four DOS-based technical modules (SFM, BFM, GLBM, and GATM) were recoded from Microsoft QuickBasic to ANSIC. These modules werethen recompiled into executable files that are compatible with both 32-bit and 64-:bit Microsoft operating systems. No changes were made to the engineering models within these four technical modules.
2-1
Summary of Changes in Version 4.0 Note: To ensure no changes were made to the engineering modules during this recoding effort, verification and validation activities included the following:
Complete line-by-line code review of each new ANSI C module; comparing it to its original QuickBasic module code ( code reviewer was independent of code developer)
Individual unit testing of each new ANSI C module using validation test cases designed to exercise all potential input options for that module; comparing the results from each test case to results from that same test case performed with its original QuickBasic module (the scope of the validation test cases for each module matched or exceeded those performed during the original development of the PPM methodology in the 1990's).
Incorporate EPRI Refined Gate Valve Unwedging Methodology For Version 4.0, the PPM software was revised to include an option to use the EPRI Refined Gate Valve Unwedging Methodology as defined in Addendum 3 to EPRI TR-I03237-R2 (Reference I). As documented in Reference 1, the USNRC has reviewed this refined unwedging methodology and issued a Safety Evaluation for this methodology.
Software Issue/Error Corrections Information Notice 2014-1: Gate Valve Applicability Table For Version 4.0, the PPM software was revised to include the latest revision of the Gate Valve Applicability Table, as documented in EPRI PPM Information Notice 2014-01 (included in Appendix A).
Problem Report 2014-02: Missing Reference Numbers in Globe Valve Prediction Report For Version 4.0, the PPM software was revised to address minor errors in the Globe Valve Prediction Output Report, as documented in EPRI PPM Problem Report 2014-02 (included in Appendix A). Specifically, the problem report notes that the PPM software allowed users to identify references for individual design inputs; however, in the PPM prediction output report for a globe valve analysis, the reference numbers were not printed for the following design inputs:
Actuator Overall Ratio Motor Speed Stem Thread Type Stem Thread Lead Stem Thread Pitch 2-2
Summary of Changes in Version 4.0 Error Notice 2015-01: Restrictor Modeling For Version 4.0, the PPM software was revised to address errors related to the modeling of restrictors, as documented in EPRI PPM Error Notice 2015-01 (included in Appendix A).
Specifically, these errors in the UIM module did not allow users to execute the PPM software if modeling an orifice or nozzle/venturi in PPM Versions 3.1 through 3.5. In Versions 3.1 through 3.5, the UIM module would issue an error message and halt execution if a user attempted to model an orifice or nozzle/venture.
Note: This Version 4.0 software revision did not alter the engineering equations/methods in the System Flow Module for modeling orifices/nozzles/venturies. This revision only corrected an error in the software which made it impossible to model these restrictor types. These restrictor types were able to be modeled in PPM Versions 1.0 and 2.0, which had a DOS-based user-interface.
Error Notice 2017-01: SFM modeling of Two-Phase Flow Scenarios For Version 4.0, the PPM software was revised to correct an error in the SFM module related to modeling two-phase flow scenarios, as documented in Error Notice 2017-01 (included in Appendix A). This error was identified in the original SFM software code during re-coding of the SFM for 64-bit compatibility. As detailed in the error notice, this error had the potential to cause non-conservative prediction results for certain two-phase flow scenarios.
Problem Report 2017-02: Gate Valve Model Dimensional Checks For Version 4.0, the PPM software was revised to address an issue in the GATM module algorithm that checks internal valve dimensions, as described in Problem Report 2017..:02 (included in Appendix A). This issue was identified in the original GATM software code during re-coding of the GATM module for 64-bit compatibility. As detailed in the problem report, this issue did not affect the prediction results from the GATM module; this issue only affected potential warning messages provided to a user if the user entered incorrect gate valve internal dimensions. As noted in the problem report, the accuracy of the software inputs is ultimately the responsibility of the user. However, this revision to the PPM code for Version 4.0 improves the capability of the code to detect if a user has entered inconsistent valve internal dimensions.
Problem Report 2017-03: Globe Valve Model Orientation Check For Version 4.0, the PPM software was revised to address an issue in the GLBM module algorithm that checks valve orientation to determine the effect of disk and stem weight, as described in Problem Report 2017-03 (included in Appendix A). This issue was identified in the original GLBM software code during re-coding of the GLBM module for 64-bit compatibility.
As detailed in the problem report, this issue did not affect the prediction results from the GLBM module; this issue only affected potential warning messages provided to the user if the user entered incorrect globe valve orientation angles (pitch and roll). As noted in the problem report, the accuracy of the software inputs is ultimately the responsibility of the user. However, this revision to the code for Version 4.0 improves the capability of the code to detect if a user has entered inconsistent pitch and roll angles.
2-3
Summary of Changes in Version 4.0 Problem Report 2017-04: Clarify Use of ERM vs. Full SFM For Version 4.0, the PPM software user manual was revised to clarify use of the Equivalent Resistance Method (ERM) versus the Full System Flow Method (Full SFM), as described in Problem Report 2017-04 (included in Appendix A). As detailed in the Problem Report, this issue only affected the user manual; no software revisions were required. Specifically, the software user manual was updated to clearly indicate the system configuration that is modeled by the PPM when users select either the ERM or the Full SFM.
Problem Report 2017-05, Rev. 1: WUIM Gate Valve Piping Labels For Version 4.0, the PPM software was revised to address an issue in the WUIM module with regard to the piping labels displayed in the gate valve user interface (Pipe Data Tab), as described in Problem Report 2017-05, Rev. 1 (included in Appendix A). As detailed in the Problem Report, there is an error in the WUIM module of PPM v3.5; the piping labels on the Gate Valve Pipe Data Tab do not update in accordance with the user-selected system modeling methodology. This issue did not affect the prediction results.
Problem Report 2018-01: Modal I Non-modal Window Error For Version 4.0, the PPM software was revised to address an error in the WUIM module which may occur when a user has two or more PPM analyses open at the same time. Specifically, under certain circumstances, the software would issue a runtime error message to the user and then shutdown (crash). When this error occurs, no prediction results are provided and no files are saved. Accordingly, this error does not have the potential to affect prediction results.
However, the revision to the PPM code for Version 4.0 to address this issue improves the usability of the software.
EPRI Code Revision Request: Change "English Units" to "US Customary Units" For Version 4.0, the PPM software and user manual were revised to change the terminology "English Units" to "US Customary Units." There is no error associated with this software revision. This revision was simply a "cosmetic" change requested by EPRI.
2-4
3 CONCLUSIONS PPM Version 4.0 was developed in accordance with a Quality Assurance Program that satisfies 10 CFR 50, Appendix Band ASME NQA-1. All software revisions from Version 3.5 to Version 4.0 were documented and independently verified. The modified software was independently validated in accordance with written test plans to verify that the software performed its required functions. A verification and validation report summarizes the requirements, design, and testing of Version 4.0 of the PPM and documents the results of validation testing.
There were no changes to the PPM methodology or its implementation approach. Accordingly, it is concluded that the assessment of previous versions of the PPM is applicable to Version 4.0.
3-1
4 REFERENCES
- 1. EPRI 1020350, Addendum 3 to EPRI TR-103237-R2: An Improved and Validated Gate Valve Unwedging Methodology-A, March 2010..
4-1
A PPM PROBLEM REPORTS, INFORMATION NOTICES, AND ERROR NOTICES This appendix contains the following problem reports, information notices, and error notices discussed in this document. This appendix is 3 8 pages, including this cover page.
Information Notice 2014-1 Problem Report 2014-02 Error Notice 2015-01 Error Notice 2017-01 Problem Report 2017-02 Problem Report 2017-03 Problem Report 2017-04 Problem Report 2017-05, Rev. 1 Problem Report 2018-01 A-1
PPM Problem Reports, Information Notices, and Error Notices Content Deleted
. EPRI Proprietary Information A-2 TS
PPM Problem Reports, Information Notices, and Error Notices Content Deleted
. EPRI Proprietary lrtfonnation TS A-3
I I*
I I
PPM Problem Reports, Information Notices, and Error Notices A-4
- Content I)eleted
- EPRi Proprietary Information TS
PPM Problem Reports, Information Notices, and Error Notices
- Content Deleted EPRI Proprietary mfonni:ttion.
TS A-5
PPM Problem Reports, Information Notices, and Error Notices Content Deleted EPRI PmprietaryTrifmmatioh A-6 TS
PPM Problem Reports, Information Notices, and Error Notices
- Content Deleted EPRI Proprietary Information TS A-7
PPM Problem Reports, Information Notices, and Error Notices Content Deleted
- EPRI Proprietary Information A-8 TS
PPM Problem Reports, Information Notices, andError Notices Content D,~leted EPRI ProP.rietary Iriforn:iation TS A-9
PPM Problem Reports, Information Notices, and Error Notices Content Deleted EPR,J Propri~taiy, Information A-10 TS
PPM Problem Reports, Information Notices, and Error Notices
<;:ontent Del.eted EPRI. Proprietary :Information
, TS A-11
PPM Problem Reports, Information Notices, and Error Notices A-12
. Content Deleted EPR,IProprieta:ry !~formation TS
PPM Problem Reports, Information Notices, and Error Notices Con:tent Deleted EPRI Proprietary Information
~
TS A-13
PPM Problem Reports, Information Notices, and Error Notices Content Deleted EPRI Proprietary Information A-14 TS
PPM Problem Reports, Information Notices, and Error Notices Content Deleted EPRI Proprietary Information TS A-15
PPM Problem Reports, Information Notices, and Error Notices Content,Deleted EPRI Proprietary Information A-16 TS
PPM Problem Reports, Information Notices, and Error Notices Content Deleted EPRI Proprietary Information TS A-17
PPM Problem Reports, Information Notices, and Error Notices Content Deleted EPRI Proprietary Information A-18 TS
PPM Problem Reports, Information Notices, and Error Notices Content Deleted EPRI Proprietary Information
- TS A-19
PPM Problem Reports, Information Notices, and Error Notices Content Deleted EPRI Proprietary Information A-20 TS
PPM Problem Reports, Information Notices, and Error Notices Content Deleted.
EPRI Proprietary' Information TS A-21
PPM Problem Reports, Information Notices, and Error Notices Cont.eni Deleted EP.RI Proprietary Information A-22 TS
PPM Problem Reports, InformationNotices, and Error Notices Content Deleted E,PRI Proprietary Information TS A-23
PPM Problem Reports, Information Notices, and Error Notices Content Deleted EPRJ
- Proprietary Infonnation A-24 TS
PPM Problem Reports, Jriformation Notices, and Error Notices Content Deleted
- EPRI Proprietary Infomiatiqn TS A-25
PPM Problem Reports, Information Notices, and Error Notices Content Deleted.
. EPRI Proprietary Information..
A-26 TS
PPM Problem Reports, Information Notices, and Error Notices Content Deleted EPRI Proprietary Information A-28 TS
PPM Problem Reports, Information Notices, and Error Notices Content Deleted EPRI Proprietary Information.
A-30 TS
PPM Problem Reports, Information Notices, and Error Notices Content Deleted EPRI Proprietary Information.
- TS A-31
I
- 1.
I I
I PPM Problem Reports, Information Notices, and Error Notices Content Deleted.
.
- EPRI Proprietary fuforniatioij.
A-32 TS
PPM Problem Reports, Information Notices, and Error Notices Content Deleted EPRI *Propriet<J,ry,lnfonilation TS A-33
PPM Problem Reports, Information Notices, and Error Notices Content Deleted
- EPRI PropJietafy b:fonnation A-34 TS
PPM Problem Reports, Information Notices, and Error Notices
- ContentUeleted EPRI Proprietary Information TS A-35
PPM Problem Reports, Information Notices, and Error Notices Content Deleted.
EPRI P~~prietafy I~onriatiou A-36 TS
PPM Problem Reports, Information Notices, and Error Notices Content Deleted *
- EPRl Proprietary. Information TS A-37
PPM Problem Reports, Information Notices, and Error Notices 1
Content Deleted EPRI Proprietaryinformation A-38 TS
Export Control Restrictions Access to and use of EPRI Intellectual Property is granted with the spe-cific understanding.and requirement that responsibility for ensuring full compliance with all applicable U.S. and foreign export laws and regu-lations is' being undertaken by you and your company. This includes an obligation to ensure that ariy individual receiving access hereunder
'v\\lho.is not a U.S. citizen or permanent U.S. resident is permitted access under applicable U.S. and foreign export laws and regulations. In the event you are uncertain whether you or your company may lawfully obtain access to this EPRI Intellectual Property, you acknowledge that it is your obligation to consult with your company's legal counsel to deter-mine whether this access is lawful. Although EPRI may make available on a case-by-case basis an informal assessment ohhe applicable U.S.
export classification for specific EPRI Intellectual Property, you and your company acknowledge that this assessment is solely for informational purposes and not for reliance purposes. You and your company ac-knowledge that it is still the obligation of you and your company to make your own assessment of the applicable U.S. export classification and ensure compliance accordingly. You and your company understand and acknowledge your obligations to make a prompt report to EPRI and the appropriate authorities regarding any access to or use of EPRI Intellec-tual Property hereunder that may be in violation of applicable U.S. or foreign export laws or regulations.
The Electric Power Research Institute, Inc. (EPRI, www.epri.corn) conducts research and development relating to the generation, delivery and use of electricity for the benefit of the public. An independent, nonprofit organization, EPRI brings together its scientists and engineers as well as experts from academia and industry to help address.
challenges in electricity, including reliability, efficiency, affordability, health, safety and the environment. EPRI members represent 90% of.the electric utility revenue in the United States with internaiionalparticipatibn in 35 countries. EPRl's principal offices and laboratories are located in Palo Alto, Calif.; Charlotte, N.C.; Knoxville, Tenn.; and Lenox, Mass.
Together... Shaping the Future of Electricity Programs:
Nuclear Power Nuclear Maintenance Applications Center