ML18248A258

From kanterella
Jump to navigation Jump to search
Framatome Inc. Required Reporting of Effluents Per 10 CFR 70.59 for Period of January 1 Through June 30, 2018
ML18248A258
Person / Time
Site: Framatome ANP Richland
Issue date: 08/31/2018
From: Sakach Y
Framatome
To:
Document Control Desk, Office of Nuclear Material Safety and Safeguards
References
YRS:18:012
Download: ML18248A258 (4)


Text

framatome August 31, 2018 YRS:18:012 U.S. Nuclear Regulatory Commission Attn: Document Control Desk (03-H8)

Director, Office of Nuclear Material Safety and Safeguards One White Flint North 11555 Rockville Pike Rockville, Maryland 20852-2738 License SNM-1227 Docket 70-1257

Subject:

Required Reporting of Effluents per 10 CFR 70.59 As required by 10 CFR 70.59, Framatome is reporting discharges of radioactive materials in the effluents from its nuclear fuels fabrication plant on Horn Rapids Road in Richland, Washington for the period from January 1 through June 30, 2018.

During the first six months of 2018, K46 exceeded 10 CFR 20 Appendix B Table 2 Effluent Concentrations for air. Corrective Action Report 2018-7738 was generated to address this issue. The release was less than five times the Table 2 limits and did not exceed the ALARA limit of 10 mrem. Initial dose calculations utilizing CAP88 Version 4 indicate potential TEDE to MEI of 9.13 E-5 mrem from this stack release.

If there are any questions, please contact me at (509) 375-8355 cc:

L. A. Dudes, U.S. Nuclear Regulatory Commission, Region II P. J. Martell, State of Washington Department of Health N. A. Pitoniak, U. S. Nuclear Regulatory Commission, Region II M. Elsen, Director, Office of Radiation Protection (WDOH)

Framatome Inc.

2101 Horn Rapids Road Richland, WA 99354 Tel: (509) 375-8100 www.framatome.com

rE49 j\\Jtv/5520
JM
;.5

USN RC Document Control Desk August 31, 2018

  • Average Stack Cc;mcentration

(µCi/ml)

Gaseo1,1s Effluent

,January 1 - June 30, 2018 Estimated Average MDC (µCi/ml)*

Low Enriched Uranium based on alpha K03 6.28E-16 3.10E-17 K06 6.02E-16 7.?0E-17 K21 1.98E-15 1.36E-16 K25 4.59E-16 3.68E-16 K31 8.89E-16 1.24E-16**

K37 4.81 E-16 7.19E-17 K42 4.39E-16 2.48E-16 K46 6.10E-14 7.79E-17 K47 2.76E-15 3.42E-16 K49 4.?0E-16 1.16E-16 KSO O.OOE+OO***

O.OOE+OO K52 4.42E-16 1.69E-16 K55 O.OOE+OO***

O.OOE+OO K56 6.54E-16 1.64E-15 K58 3.38E-16 6.40E-17 K60 6.10E-16 6.92E-17 K62 4.92E-16 2.04E-17 K65 3.84E-16 4.21E-16 K67 5.89E-16 1.04E-15 K69 8.97E-16 2.50E-16 K72 9.24E-16 3.67E-17 K75 5.89E-16 9.97E-16

  • TOTAL Estimated average minimum detectable concentrations for 7-day sampling.

.* Quantity

(µCi alpha) 0.15 0.06 0.11 0.01 0.21 0.05 0.01 5.73 0.06 0.03 0.00 0.02 0.00 0.00 0.04 0.06 0.18 0.01 0.00 0.03 0.18 0.00 6.94 YRS:18:012 Page 2 Flow'.(m3) 2.68E+08 9.50E+07 5.37E+07 1.99E+07 2.36E+08 1.02E+08 2.95E+07 9.40E+07 2.14E+07 6.32E+07 O.OOE+OO 4.34E+07 O.OOE+OO 4.46E+06 1.14E+08 1.06E+08 3.58E+08 1.74E+07 7.01E+06 2.92E+07 2.00E+08 7.35E+06

't There are several sampled effluent streams discharged via this stack, MDC listed is the highest of any sampled effluent stream

      • Stack did not operate during first half of 2018.

Gaseous Effh;1ent,

\\'

January 1 _:: June 30, 2018 Average

. Aver:a{Je MDC.

Qu"ntity

  • Stack Concentration
  • Flow(m3)

(µCi/ml}

(µCi/ml)*

(µCi beta)**

Mixed Fission and Activation Corrosion Products-Based upon Gross Beta results K52 8.32E-15 5.11E-16 0.36 4.34E+07 TOTAL 0.36 Estimated average minimum detectable concentration for 7-day sampling.

Principal isotopes (by activity) are estimated to be Co-60 (-66%), Mn-54 (-20%), and Sb-125 (-9%).

Framatome Inc.

2101 Horn Rapids Road Richland, WA 99354 Tel: (509) 375-8100 www.framatome.com

USNRC Document Control Desk August 31, 2018

  • Average Stack Concentration

(µCi/ml}*

Radionuclide: Rn-220 K03 3.23E-:09 K31 O.OOE+OO K37 O.OOE+OO K50 O.OOE+OO K56 O.OOE+OO K72 O.OOE+OO K75 O.OOE+OO TOTAL Averag~ MDC Quantity

(µCi/ml}*

(µCi}

7.63E+05 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO

~

6.10E+05 Flow (m3)

YRS:18:012 Page 3 2.36E+08 2.36E+08 1.02E+08 O.OOE+OO**

4.46E+06 2.00E+08 7.35E+06 Radon concentrations are determined by e-perms, which rely on changes in voltage; not counting instruments.

    • Stack did not operate during first half of 2018.

USN RC Document Control Desk August 31, 2018 Liquid Effluent*

January 1 -June 30, 2018 Constituent

. Concentratioo LlLD

(µCi/ml}

(µCi/ml}

Soluble U 8.60E-08 Insoluble U**

1.76E-07 Tc-99 1.20E-07 Total Ci Combined liquid effluent released to City of Richland sewer system.

Qu~ntity(Ci) 0.0027 0.0054 0.0037 0.0118 YRS:18:012 Page 4 Liquid,

Volume (m3) 3.08E+04 The average concentration of insoluble uranium for the 6-month period was less than 50 ppb.

These constituents are analyzed chemically via Inductively Coupled Plasma/Mass Spectroscopy (ICP/MS) as opposed to radiation counting. Laboratory detection limits for uranium and Tc-99 are generally 1 ppb and 5 ppt, respectively