ML18239A196
| ML18239A196 | |
| Person / Time | |
|---|---|
| Site: | Vogtle |
| Issue date: | 09/27/2018 |
| From: | Paul Kallan NRC/NRO/DLSE/LB4 |
| To: | Southern Nuclear Operating Co |
| KALLAN P/415-2809 | |
| Shared Package | |
| ML18239A192 | List: |
| References | |
| EPID L-2017-LLA-0097, LAR-17-031 | |
| Download: ML18239A196 (17) | |
Text
ATTACHMENT TO LICENSE AMENDMENT NO. 144 TO FACILITY COMBINED LICENSE NO. NPF-91 DOCKET NO.52-025 Replace the following pages of the Facility Combined License No. NPF-91 with the attached revised pages. The revised pages are identified by amendment number and contain marginal lines indicating the areas of change.
Facility Combined License No. NPF-91 REMOVE INSERT 7
7 Appendix A to Facility Combined License Nos. NPF-91 and NPF-92 REMOVE INSERT 3.1.3-1 3.1.3-1 3.1.3-2 3.1.3-2 3.2.1-1 3.2.1-1 3.2.1-2 3.2.1-2 3.2.1-4 3.2.1-4 3.2.1-5 3.2.1-5 3.2.2-1 3.2.2-1 3.2.2-2 3.2.2-2 3.2.2-3 3.2.2-3 3.2.5-1 3.2.5-1 3.3.1-2 3.3.1-2 3.3.1-3 3.3.1-3 3.7.1-2 3.7.1-2 5.6-4 5.6-4 5.6-5 5.6-5
(7) Reporting Requirements (a)
Within 30 days of a change to the initial test program described in UFSAR Section 14, Initial Test Program, made in accordance with 10 CFR 50.59 or in accordance with 10 CFR Part 52, Appendix D, Section VIII, Processes for Changes and Departures, SNC shall report the change to the Director of NRO, or the Directors designee, in accordance with 10 CFR 50.59(d).
(b)
SNC shall report any violation of a requirement in Section 2.D.(3),
Section 2.D.(4), Section 2.D.(5), and Section 2.D.(6) of this license within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. Initial notification shall be made to the NRC Operations Center in accordance with 10 CFR 50.72, with written follow up in accordance with 10 CFR 50.73.
(8) Incorporation The Technical Specifications, Environmental Protection Plan, and ITAAC in Appendices A, B, and C, respectively of this license, as revised through Amendment No. 144, are hereby incorporated into this license.
(9) Technical Specifications The technical specifications in Appendix A to this license become effective upon a Commission finding that the acceptance criteria in this license (ITAAC) are met in accordance with 10 CFR 52.103(g).
(10) Operational Program Implementation SNC shall implement the programs or portions of programs identified below, on or before the date SNC achieves the following milestones:
(a)
Environmental Qualification Program implemented before initial fuel load; (b)
Reactor Vessel Material Surveillance Program implemented before initial criticality; (c)
Preservice Testing Program implemented before initial fuel load; (d)
Containment Leakage Rate Testing Program implemented before initial fuel load; (e)
- 1.
The fire protection measures in accordance with Regulatory Guide (RG) 1.189 for designated storage building areas (including adjacent fire areas that could affect the storage area) implemented before initial receipt 7
Amendment No. 144
Technical Specifications MTC 3.1.3 VEGP Units 3 and 4 3.1.3 - 1 Amendment No. 144 (Unit 3)
Amendment No. 143 (Unit 4) 3.1 REACTIVITY CONTROL SYSTEMS 3.1.3 Moderator Temperature Coefficient (MTC)
LCO 3.1.3 The MTC shall be maintained within the limits specified in the COLR.
APPLICABILITY:
MODE 1 for the upper MTC limit.
MODE 2 with keff 1.0 for the upper MTC limit.
MODES 1, 2, and 3 for the lower MTC limit.
ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.
MTC not within upper limit.
A.1 Restore MTC within limit.
24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> B.
Required Action and associated Completion Time of Condition A not met.
B.1 Be in MODE 2 with keff < 1.0.
6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> C.
MTC not within lower limit.
C.1 Be in MODE 4.
12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.1.3.1 Verify MTC within upper limit.
Once prior to entering MODE 1 after each refueling
Technical Specifications MTC 3.1.3 VEGP Units 3 and 4 3.1.3 - 2 Amendment No. 144 (Unit 3)
Amendment No. 143 (Unit 4)
SURVEILLANCE REQUIREMENTS (continued)
SURVEILLANCE FREQUENCY SR 3.1.3.2
- NOTES -
- 1.
Not required to be performed provided applicable criteria in the COLR are satisfied.
- 2.
Not required to be performed if the MTC measured at the equivalent of equilibrium RTP all rods out (ARO) boron concentration of 60 ppm is less negative than the 60 ppm Surveillance limit specified in the COLR.
Verify MTC is within lower limit.
Once within 7 effective full power days (EFPD) after reaching the equivalent of an equilibrium RTP ARO boron concentration of 300 ppm AND 14 EFPD thereafter when MTC is more negative than the 300 ppm Surveillance limit (not LCO limit) specified in the COLR
Technical Specifications FQ(Z) (CAOC W(Z) Methodology) 3.2.1 VEGP Units 3 and 4 3.2.1 - 1 Amendment No. 144 (Unit 3)
Amendment No. 143 (Unit 4) 3.2 POWER DISTRIBUTION LIMITS 3.2.1 Heat Flux Hot Channel Factor (FQ(Z)) (Constant Axial Offset Control (CAOC) W(Z)
Methodology)
LCO 3.2.1 FQ(Z), as approximated by
)
Z
(
FC Q
and
)
Z
(
FW Q
, shall be within the limits specified in the COLR.
APPLICABILITY:
MODE 1 with THERMAL POWER 25% RTP and with On-Line Power Distribution Monitoring System (OPDMS) not monitoring parameters.
ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.
- NOTE -
Required Action A.3 shall be completed whenever this Condition is entered.
)
Z
(
FC Q
not within limit.
A.1 Reduce THERMAL POWER 1% RTP for each 1%
)
Z
(
FC Q
exceeds limit.
15 minutes after each
)
Z
(
FC Q
determination AND A.2 Reduce Overpower T trip setpoints 1% for each 1%
)
Z
(
FC Q
exceeds limit.
72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> after each
)
Z
(
FC Q
determination AND A.3 Perform SR 3.2.1.1 and SR 3.2.1.2.
Prior to increasing THERMAL POWER above the limit of Required Action A.1
Technical Specifications FQ(Z) (CAOC W(Z) Methodology) 3.2.1 VEGP Units 3 and 4 3.2.1 - 2 Amendment No. 144 (Unit 3)
Amendment No. 143 (Unit 4)
ACTIONS (continued)
CONDITION REQUIRED ACTION COMPLETION TIME B.
- NOTE -
Required Action B.3 shall be completed whenever this Condition is entered.
)
Z
(
FW Q
not within limits.
B.1 Reduce THERMAL POWER 1% for each 1%
)
Z
(
FW Q
exceeds limit.
4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> AND B.2 Reduce Overpower T trip setpoints 1% for each 1%
)
Z
(
FW Q
exceeds limit.
72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> AND B.3 Perform SR 3.2.1.1 and SR 3.2.1.2.
Prior to increasing THERMAL POWER above the limit of Required Action B.1 C.
Required Action and associated Completion Time not met.
C.1 Reduce THERMAL POWER < 25% RTP.
6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />
Technical Specifications FQ(Z) (CAOC W(Z) Methodology) 3.2.1 VEGP Units 3 and 4 3.2.1 - 4 Amendment No. 144 (Unit 3)
Amendment No. 143 (Unit 4)
SURVEILLANCE REQUIREMENTS (continued)
SURVEILLANCE FREQUENCY SR 3.2.1.3
- NOTE -
Not required to be performed until 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after OPDMS not monitoring parameters.
Verify
)
Z
(
FC Q
within limit.
Once within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after achieving equilibrium conditions after exceeding, by 10% RTP, the THERMAL POWER at which
)
Z
(
FC Q
was last verified AND 31 effective full power days (EFPD) thereafter
Technical Specifications FQ(Z) (CAOC W(Z) Methodology) 3.2.1 VEGP Units 3 and 4 3.2.1 - 5 Amendment No. 144 (Unit 3)
Amendment No. 143 (Unit 4)
SURVEILLANCE REQUIREMENTS (continued)
SURVEILLANCE FREQUENCY SR 3.2.1.4
- NOTES -
- 1.
Not required to be performed until 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after OPDMS not monitoring parameters.
- 2.
If
)
Z
(
FW Q
measurements indicate maximum over z
)
Z
(
FC Q
has increased since the previous evaluation of
)
Z
(
FC Q
- a.
Increase
)
Z
(
FW Q
by the greater of a factor of 1.02 or by an appropriate factor specified in the COLR and reverify
)
Z
(
FW Q
is within limits; or
- b.
Repeat SR 3.2.1.4 once per 7 EFPD until two successive flux maps indicate maximum over z
)
Z
(
FC Q
has not increased.
Verify
)
Z
(
FW Q
within limits.
Once within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after achieving equilib-rium conditions after exceeding, by 10% RTP, the THERMAL POWER at which
)
Z
(
FW Q
was last verified AND 31 EFPD thereafter
Technical Specifications N
H F
3.2.2 VEGP Units 3 and 4 3.2.2 - 1 Amendment No. 144 (Unit 3)
Amendment No. 143 (Unit 4) 3.2 POWER DISTRIBUTION LIMITS 3.2.2 Nuclear Enthalpy Rise Hot Channel Factor (
N H
F)
H F shall be within the limits specified in the COLR.
APPLICABILITY:
MODE 1 with THERMAL POWER 25% RTP and with On-Line Power Distribution Monitoring System (OPDMS) not monitoring parameters.
ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.
- NOTE -
Required Actions A.2 and A.3 must be completed whenever Condition A is entered.
N H
Fnot within limits.
A.1.1 Restore N
H F to within limit.
4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> OR A.1.2.1 Reduce THERMAL POWER to < 50% RTP.
4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> AND A.1.2.2 Reduce Overpower T trip setpoints to 55% RTP.
72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> AND A.2 Perform SR 3.2.2.1.
24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> AND
Technical Specifications N
H F
3.2.2 VEGP Units 3 and 4 3.2.2 - 2 Amendment No. 144 (Unit 3)
Amendment No. 143 (Unit 4)
ACTIONS (continued)
CONDITION REQUIRED ACTION COMPLETION TIME A.3
- NOTE -
THERMAL POWER does not have to be reduced to comply with this Required Action.
Perform SR 3.2.2.1.
Prior to THERMAL POWER exceeding 50% RTP AND Prior to THERMAL POWER exceeding 75% RTP AND 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after THERMAL POWER reaching 95% RTP B.
Required Action and associated Completion Time not met.
B.1 Reduce THERMAL POWER to < 25% RTP.
6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />
Technical Specifications N
H F
3.2.2 VEGP Units 3 and 4 3.2.2 - 3 Amendment No. 144 (Unit 3)
Amendment No. 143 (Unit 4)
SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.2.2.1
- NOTE -
Not required to be performed if OPDMS was monitoring parameters upon exceeding 75% RTP.
Verify N
H F within limits specified in the COLR.
Once after each refueling prior to THERMAL POWER exceeding 75% RTP SR 3.2.2.2
- NOTE -
Not required to be performed until 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after OPDMS not monitoring parameters.
Verify N
H F within limits specified in the COLR.
31 effective full power days (EFPD)
Technical Specifications OPDMS-Monitored Parameters 3.2.5 VEGP Units 3 and 4 3.2.5 - 1 Amendment No. 144 (Unit 3)
Amendment No. 143 (Unit 4) 3.2 POWER DISTRIBUTION LIMITS 3.2.5 On-Line Power Distribution Monitoring System (OPDMS)-Monitored Parameters LCO 3.2.5 The following parameters shall not exceed their operating limits as specified in the COLR:
- a.
Peak Linear Heat Rate;
- b.
N H
F;
- c.
DNBR; and
- d.
SDM.
APPLICABILITY:
MODE 1 with THERMAL POWER 25% RTP and with OPDMS monitoring parameters a, b, and c.
MODE 1 with OPDMS monitoring parameter d.
MODE 2 with keff 1.0 and OPDMS monitoring parameter d.
ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.
One or more of the parameters a. through
- c. above not within limits.
A.1 Restore all parameters to within limits.
1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> B.
Required Action and associated Completion Time of Condition A not met.
B.1 Reduce THERMAL POWER to < 25% RTP.
4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> C.
Parameter d above not within limits.
C.1 Initiate boration to restore SDM to within limits.
15 minutes SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.2.5.1 Verify the parameters a. through d. to be within their limits.
24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />
Technical Specifications RTS Instrumentation 3.3.1 VEGP Units 3 and 4 3.3.1 - 2 Amendment No. 144 (Unit 3)
Amendment No. 143 (Unit 4)
ACTIONS (continued)
CONDITION REQUIRED ACTION COMPLETION TIME E.
As required by Required Action C.1 and referenced in Table 3.3.1-1.
E.1 Reduce THERMAL POWER to < P-10.
6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> SURVEILLANCE REQUIREMENTS
- NOTE -
Refer to Table 3.3.1-1 to determine which SRs apply for each RTS Function.
SURVEILLANCE FREQUENCY SR 3.3.1.1 Perform CHANNEL CHECK.
12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> SR 3.3.1.2
- NOTES -
- 1.
Required to be met within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after reaching 15% RTP.
- 2.
If the calorimetric heat balance is 15% RTP, and if the nuclear instrumentation channel indicated power is:
- a.
lower than the calorimetric measurement by
> 5% RTP, then adjust the nuclear instrumentation channel upward to match the calorimetric measurement.
- b.
higher than the calorimetric measurement, then no adjustment is required.
Compare results of calorimetric heat balance to nuclear instrument channel output.
24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />
Technical Specifications RTS Instrumentation 3.3.1 VEGP Units 3 and 4 3.3.1 - 3 Amendment No. 144 (Unit 3)
Amendment No. 143 (Unit 4)
SURVEILLANCE REQUIREMENTS (continued)
SURVEILLANCE FREQUENCY SR 3.3.1.3
- NOTES -
- 1.
Adjust the conversion factor, T°, in the T power calculation (qT) if absolute difference between qT and the calorimetric measurement is > 3% RTP.
- 2.
Required to be met within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after reaching 50% RTP.
- 3.
If the calorimetric heat balance is < 70% RTP, and if qT is:
- a.
lower than the calorimetric measurement by
> 5%, then adjust T° to match the calorimetric measurement.
- b.
higher than the calorimetric measurement, then no adjustment is required.
Compare results of calorimetric heat balance to the T power calculation (qT) output.
24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> SR 3.3.1.4
- NOTES -
- 1.
Adjust nuclear instrument channel in PMS if absolute difference is 1.5% AFD.
- 2.
Required to be met within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after reaching 20% RTP.
Compare results of the incore detector measurements to nuclear instrument channel AXIAL FLUX DIFFERENCE.
31 effective full power days (EFPD)
- NOTE -
Required to be met within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after reaching 50% RTP.
Calibrate excore channels to agree with incore detector measurements.
92 EFPD
Technical Specifications MSSVs 3.7.1 VEGP Units 3 and 4 3.7.1 - 2 Amendment No. 144 (Unit 3)
Amendment No. 143 (Unit 4)
ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.
(continued)
A.2
- NOTE -
Only required in MODE 1.
Reduce the Overpower T reactor trip setpoints to less than or equal to the Maximum Allowable %
RTP specified in Table 3.7.1-1 for the number of OPERABLE MSSVs.
36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> B.
One or both steam generators with one or more MSSVs inoperable for closing.
B.1 Restore MSSV to OERABLE status.
72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> C.
Required Action and associated Completion Time of Condition A not met.
OR One or both steam generators with 5 MSSVs inoperable for opening.
C.1 AND C.2 Be in MODE 3.
Be in MODE 4 with the RCS cooling provided by the RNS.
6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> 24 hours D.
Required Action and associated Completion Time of Condition B not met.
D.1 AND D.2 Be in MODE 3.
Be in MODE 5.
6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> 36 hours
Technical Specifications Reporting Requirements 5.6 VEGP Units 3 and 4 5.6 - 4 Amendment No. 144 (Unit 3)
Amendment No. 143 (Unit 4) 5.6 Reporting Requirements 5.6.3 CORE OPERATING LIMITS REPORT (COLR) (continued)
- 6.
APP-GW-GLR-137, Revision 1, Bases of Digital Overpower and Overtemperature Delta-T (OPT/OTT) Reactor Trips, Westinghouse Electric Company LLC.
(Methodology for Specification 2.1.1 - Reactor Core Safety Limits.)
7a. WCAP-16045-P-A, Qualification of the Two-Dimensional Transport Code PARAGON, August 2004 (Westinghouse Proprietary) and WCAP-16045-NP-A, (Non-Proprietary).
(Methodology for Specification 3.1.3 - Moderator Temperature Coefficient (MTC).)
7b. WCAP-16045-P-A, Addendum 1-A, Qualification of the NEXUS Nuclear Data Methodology, August 2007 (Westinghouse Proprietary) and WCAP-16045-NP-A, Addendum 1-A, (Non-Proprietary).
(Methodology for Specification 3.1.3 - Moderator Temperature Coefficient (MTC).)
7c. WCAP13749PA, Safety Evaluation Supporting the Conditional Exemption of the Most Negative EOL Moderator Temperature Coefficient Measurement, March 1997 (Westinghouse Proprietary).
(Methodology for Specification 3.1.3 - Moderator Temperature Coefficient (MTC).)
- c.
The core operating limits shall be determined such that all applicable limits (e.g., fuel thermal mechanical limits, core thermal hydraulic limits, Passive Core Cooling Systems limits, nuclear limits such as SDM, transient analysis limits, and accident analysis limits) of the safety analysis are met.
- d.
The COLR, including any midcycle revisions or supplements, shall be provided upon issuance for each reload cycle to the NRC.
5.6.4 Reactor Coolant System (RCS) PRESSURE AND TEMPERATURE LIMITS REPORT (PTLR)
- a.
RCS pressure and temperature limits for heat up, cooldown, low temperature operation, criticality, and hydrostatic testing as well as heatup and cooldown rates shall be established and documented in the PTLR for the following:
3.4.3, RCS Pressure and Temperature (P/T) Limits; and 3.4.14, Low Temperature Overpressure Protection (LTOP).
Technical Specifications Reporting Requirements 5.6 VEGP Units 3 and 4 5.6 - 5 Amendment No. 144 (Unit 3)
Amendment No. 143 (Unit 4) 5.6 Reporting Requirements 5.6.4 Reactor Coolant System (RCS) PRESSURE AND TEMPERATURE LIMITS REPORT (PTLR) (continued)
- b.
The analytical methods used to determine the RCS pressure and temperature limits shall be those previously reviewed and approved by the NRC, specifically those described in the following document:
WCAP-14040-A, Methodology Used to Develop Cold Overpressure Mitigating System Setpoints and RCS Heatup and Cooldown Limit Curves.
(Limits for LCO 3.4.3 and LCO 3.4.14).
- c.
The PTLR shall be provided to the NRC upon issuance for each reactor vessel fluency period and for any revision or supplement thereto.
5.6.5 Post Accident Monitoring Report When a report is required by Condition B of LCO 3.3.17, Post Accident Monitoring (PAM) Instrumentation, a report shall be submitted within the following 14 days. The report shall outline the preplanned alternate method of monitoring, the cause of the inoperability, and the plans and schedule for restoring the instrumentation channels of the Function to OPERABLE status.
5.6.6 Steam Generator Tube Inspection Report A report shall be submitted within 180 days after the initial entry into MODE 4 following completion of an inspection performed in accordance with the Specification 5.5.4, "Steam Generator (SG) Program." The report shall include:
- a.
The scope of inspections performed on each SG,
- b.
Active degradation mechanisms found,
- c.
Nondestructive examination techniques utilized for each degradation mechanism,
- d.
Location, orientation (if linear), and measured sizes (if available) of service induced indications,
- e.
Number of tubes plugged during the inspection outage for each active degradation mechanism,
- f.
Total number and percentage of tubes plugged to date,
- g.
The results of condition monitoring, including the results of tube pulls and in-situ testing, and
- h.
The effective plugging percentage for all plugging in each SG.