Sample IDTh-232 (pCi/g)Th-232 U (1S)Ra-226 (pCi/g)Ra-226 U (1S)Th-230 (pCi/g)Th-230 U (1S)U-235 (pCi/g)U-235 U (1S)U-238 (pCi/g)U-238 U (1S)NotesWEAC-SO-017.90E-019.82E-021.86E+002.11E-01NDND2.28E-014.83E-022.23E+003.74E-01Judgemental soil sample just South of former solvent WEAC-SO-028.79E-011.12E-018.28E+009.07E-01NDND1.40E+001.77E-011.12E+012.24E+00Sample Collected near Hot Spot 4WEAC-SO-02 B6.87E-011.32E-012.22E+002.64E-01NDND4.99E-016.88E-026.78E+001.01E+00Sample Collected 1 to 2 ft below surfaceHot Spot 21.15E+008.10E-021.04E+021.19E+01NDND3.46E+004.89E-011.52E+011.18E+00Hot Spot 2 Sample Collected 2016Hot Spot 19.90E-013.90E-013.19E+017.47E+00NDNDNDND2.11E+015.82E-01Hot Spot 1 Sample Collected 2016Hot Spot 57.30E-013.20E-011.05E+014.16E+00NDNDNDND1.71E+013.20E+00Hot Spot 5 Sample Collected 2016Hot Spot 41.08E+001.24E-012.55E+012.74E+003.40E+016.96E-012.36E+002.58E-015.08E+015.63E+00Hot Spot 4 Sample Collected 2017Hot Spot 37.72E-019.04E-023.93E+014.23E+004.13E+016.97E+005.14E-011.73E-014.23E+006.07E-01Hot Spot 3 Sample Collected 2017Hot Spot 67.47E-018.69E-021.56E+011.68E+001.85E+013.56E+008.25E-011.32E-011.57E+011.77E+00Hot Spot 6 Sample Collected 2017Hot Spot 87.61E-018.83E-023.58E+013.85E+005.69E+011.01E+013.54E+003.82E-016.68E+017.35E+00Hot Spot 8 Sample Collected 20172-58.81E-011.01E-019.65E-011.05E-01NDND8.67E-023.30E-029.58E-011.23E-01Low Activity Judgemental Soil SampleWEAC-SS-0139.65E-011.19E-019.65E-011.19E-01NDND6.95E-022.66E-024.70E-011.93E-015 Point Composite of Soils just east of former Warehouse 2WEAC-SS-0148.09E-011.10E-018.80E-011.15E-01NDND1.01E-013.72E-021.12E+006.74E-015 Point Composite of Soils under former Warehouse 2WEAC-SS-0158.88E-011.08E-018.81E-011.11E-01NDND1.62E-013.52E-025.80E-012.00E-015 Point Composite of Soils under former Warehouse 2WEAC-SS-0167.59E-019.21E-021.22E+001.40E-01NDND1.06E-013.07E-025.73E-011.99E-015 Point Composite of Soils under asphalt just west of former Warehouse 2WEAC-SS-0176.44E-019.72E-025.56E-018.23E-02NDNDNDNDNDND5 Point Composite of Soils under asphalt just south of former Warehouse 2WEAC-SS-0186.93E-017.85E-028.48E-019.33E-02NDNDNDND8.83E-012.09E-015 Point Composite of Soils under former Warehouse 1WEAC-SS-0196.93E-017.85E-028.71E-011.05E-01NDNDNDNDNDND5 Point Composite of Soils under former Warehouse 1WEAC-SS-0205.70E-017.37E-021.19E+001.46E-01NDND1.75E-014.47E-02 1.031784.58E-015 Point Composite of Soils under former Warehouse 1WEAC-SS-0211.01E+003.35E-011.19E+001.44E-01NDND2.09E-014.55E-029.36E-014.44E-015 Point Composite of Soils under asphalt just south of former Warehouse 1WEAC-SS-0229.44E-011.15E-019.56E-011.19E-01NDND1.59E-013.61E-028.88E-012.42E-015 Point Composite of Soils under asphalt just east of former Warehouse 2WEAC-SS-0231.12E+001.37E-011.23E+001.57E-01NDND2.03E-015.32E-021.61E+002.72E-015 Point Composite of Soils under asphalt just southeast of former Warehouse 2WEAC-SS-0246.01E-017.53E-025.91E-017.73E-02NDNDNDND2.73E-011.65E-015 Point Composite of Soils under asphalt just south of former Warehouse 2WEAC-SS-0311.10E+003.43E-011.87E+002.13E-01NDND3.22E-015.69E-025.46E+001.63E+005 Point Composite of Soils from Hot Spot 6 excavationWEAC-SS-0329.42E-011.08E-011.82E+001.97E-01NDND2.21E-013.99E-023.05E+003.72E-015 Point Composite of Soils from Hot Spot 8 excavationWEAC-SS-0331.22E+001.55E-012.71E+002.93E-01NDND2.34E-014.55E-024.10E+004.91E-015 Point Composite of Soils from Hot Spot 6 excavationWEAC-SS-0347.04E-018.11E-027.79E-018.45E-02NDND1.26E-012.50E-022.58E+003.13E-015 Point Composite of Soils from Hot Spot 10 excavationWEAC-SS-0357.04E-018.11E-027.80E-018.45E-02NDND1.26E-012.50E-022.34E+003.02E-015 Point Composite of Soils from Hot Spot 9 excavationWEAC-SS-0369.60E-011.11E-013.13E-013.37E-01NDND3.06E-014.72E-026.54E+008.17E-01Judgemental soils sample North of Hot Spot 9PRE-REMEDIATION DATA WEAC-SS-0371.10E+001.36E-012.33E+002.74E-01NDND4.43E-018.29E-025.97E+001.57E+005 Point Composite of Soils near Hot Spot 1 excavationWEAC-SS-0388.66E-011.10E-012.84E+003.25E-01NDND7.19E-012.49E-011.18E+012.44E+005 Point Composite of Soils near Hot Spot 4 excavationWEAC-SS-039NDND1.80E+021.89E+012.26E+024.76E+012.80E+009.13E-017.11E+003.22E+00Hot Spot 4 Burial materialWEAC-SS-0407.96E-011.39E-011.70E+021.82E+012.48E+025.40E+012.53E+001.04E+001.43E+014.17E+005 point composite of Hot Spot 4 burial materialWEAC-SS-044 0.791452 0.10937912.43E+022.61E+012.67E+024.20E+012.88E+004.81E-011.25E+011.82E+00Hot Spot 2&3 Burial Material (Gray Tailings)WEAC-SS-0453.68E+004.35E-011.38E+021.49E+019.77E+013.09E+014.57E+008.91E-014.67E+016.01E+00Hot Spot 2&3 Burial Material (Yellow Brown Orange Material) found under Gray Material Detector IDU-238 MDC @ 1hr (pCi/g)U-238 MDC @ 12hr (pCi/g)Th-230 MDC @ 1hr (pCi/g)Th-230 MDC @ 12hr (pCi/g)Ra-226 MDC @ 1hr (pCi/g)Ra-226 MDC @ 12hr (pCi/g)U-235 MDC @ 1hr (pCi/g)U-235 MDC @ 12hr (pCi/g)3 3 1 45 20 10.5 20.2 19 3 1 30 15 10.5 20.223 (broad energy) 10.5 12 60.50.2 10.2 Th-232 MDC @ 1hr (pCi/g)Th-232 MDC @ 12hr (pCi/g)10.5 10.50.50.2 Abbreviations SUSigma UncertaintyNDNot Detected Above Critical LevelMDCMinimum detectable activity concentrationWACWaste CharacterizationCHRCharacterization Survey Data FSSFinal Status Survey DataMixSample contains concrete and asphalt