.. NRC FORM 374 U.S. NUCLEAR REGULATORY COMMISSION MATERIALS LICENSE PAGE 1 OF 6 PAGES Amendment No. 55 Pursuant to the Atomic Energy Act of 1954 , as amended, the Energy Reorganization Act of 1974 {Public Law 93-438), and Tttle 10, Code of Federal Regu l ations , Chapte r I, Parts 30, 31 , 32 , 33 , 34 , 35 , 36 , 37 , 39 , 40 , 70 and 71 , and in reliance on statements and representations heretofore made by the licensee , a license i s hereby issued authorizing the licensee to receive, acquire, possess , and transfer byproduct, source , and specia l nuclear material designated below; to use such material for the purpose(s) and at the place(s) designated below; to deliver or transfer such material to persons authorized to receive it in accordance with the regulations of the applicable Part(s). This license shall be deemed to contain the conditions specified in Section 183 of the Atomic Energy Act of 1954 , as amended , and is subject to all applicable rules , regulations , and orders of the Nuclear Regulatory Commission now or hereafter in effect and to any conditions specified below. Licensee 4. Expiration Date: July 7 , 2026 1. National Aeronautics and Space Administration George C. Marshall Space Flight Center "" In accordance with the letter dated June 06,2018, 2. NASA, MSFCAS10 Huntsville, AL 35812 6. Byproduct, source , and/or specia l nuclear material A. Any byproduct material between atomic numbers 3 and 83 B. Any byproduct mater i al with Atomic Numbers 84 through 91 C. lron-55 D. Cobalt-60 E. Selenium-75
.. 1---------------1
- 5. Docket No.: 030-03575
- 3. License number: 01-06571-10 is amended in its entirety to read as follows: ,,--::-;;
Reference No.: 7. Chemical and/or physical form 8. Maximum amount that licensee 9. Authorized use may possess at any one time under this license A. Any ' A. 0.6 millicuries per "'~ A. For research and development as *"""' radionuclide and 2 -~ defined in 10 CFR 30.4. '\. £ millicuries total B. Any ~* :~ B. 0.6 microcuries per B. For research and development as ¥.' " radionuclide and 2' defined i n 10 CFR 30.4. ~-microcuries total C. Sealed, Plated, or Foil Sources C. 10 millicuries per source C. For research and development as (Amersham , Model IEC.A1; and 100 millicuries total defined in 10 CFR 30.4. Isotope Products Laboratories, Model AN-55; PHl-055) D. Sealed, Plated , or Foil Sources D. 10 millicuries per source D. For research and development as (Isotope Products Laboratories, and 100 millicuries total defined in 10 CFR 30.4. Model 193; GF-60-0; GF-60-R) E. Sealed Sources (Isotope E. 10 millicuries per source E. For research and development as Products Laboratories , Model and 20 millicuries total defined in 10 CFR 30.4. R-75)
NRC F ORM 374A U.S. NUCLEAR REGULATORY COMMISSION PAGE 2 OF 6 PAGES 6. F. G. H. I. J. K. L. M. N. License Number 01-06571-10 MATERIALS LICENSE SUPPLEMENTARY SHEET Amendment No. 55 Byproduct, source , 7. Chemical and/or physical form and/or special nuclear material --Strontium-90 F. Sealed, Plated , or Foil Sources (AEA Technology/QSJ\
Inc., ..... Model SIF.01; Isotope Products Laboratories , Model BF090) Cadm i um-109 G. Sealed or plated sources (Isotope Products Laboratories , Model PHl-109; XFB-3) Barium-133 H. Plated Sour c es (Isotope Products Laboratories , Model GF-133-D;_GF-133-R)
Cesium-137 I. Sealed Sources (Isotope Products Laboratories, Model 193; GF-137: D i GF-137-R)
Gadolinium-153 J. Sealed Sources (Amersham , Model GDC.CY1) Radium-226 K. Sealed Sources (Isotope Products Laboratories, Model GF-226) Americium-241 L. Sealed Sources (Amersham/QSA, Inc., Model AMC.2084; AMN.PE1; Isotope Products Laboratories , Model AF Series; Monsanto Agricultural Company , Model 2722-BT) Americium-241 M. Foils (AEA , Model AMM.1001 H) Curium-244 N. Foils or plated sources (Isotope Products Laboratories , Model AF-210-C; AF-244-C) 8. .. -F. G. H. I T d J. K. L. M. N. Docket or Reference Number 030-03575 Maximum amount that licensee 9. Authorized use may possess at any one time under this license 10 miilicuries per source F. For research and development as and 500 millicuries total defined in 10 CFR 30.4 . 10 millicuries per source G. For research and development as and 100 millicuries total defined i n 10 CFR 30.4. 2 millicuries per source ..-H. For research and development as and 20 millicuries total defined in 10 CFR 30.4. 10 millicuries per source_ I. For research and development as and 100 millicuries total .. defined in 10 CFR 30.4. 10 millicuries per source J. For research and development as and 100 millicuries
, total defined i n 10 CFR 30.4. 10 microcuries per.source K. For research and development as and 10 microc u ries total defined in 10 CFR 30.4. 30 millicuries per source L. For research and development as and 130 millicuries total defined in 10 CFR 30.4. 10 millicuries per source M. For research and development as and 20 millicuries total defined in 10 CFR 30.4. 2 millicuries per source N. For research and development as and 20 millicuries total defined in 10 CFR 30.4.
... NRC FORM 374A U.S. NUCLEAR REGULATORY COMMISSION PAGE 3 OF 6 PAGES License Number MATERIALS LICENSE SUPPLEMENTARY SHEET 01-06571-10 Amendment No. 55 6. Byproduct , source , and/or spec i al nuclear material 0. Uranium (Natural or Depleted}
P. Uranium-depleted i n Uranium-235 Q. Krypton-85 7. Chemical and/or physical form 0. Solid (powders , pellets ,-and ceramics)
P. Solid Q. Any '""" Docket or Reference Number 030-03575 8. Maximum amount tha t licensee 9. Author i zed use may possess at any one time under this license 0. 14.6 kilograms total P. 60 kilograms total Q. 40 curies total CONDITIONS
'-" 0. Fo r research and development as defined in 10 CFR 30.4. P. For research and development as defined in 10 CFR 30.4. Q. For use i n lso Vac Enginee r ing, Inc. Radiflo Model Mark V leak testing devices. 10. Licensed material may be used or stored only at the licensee's facilities located at: George C. Marshall Space Fight Center , Huntsville , Alabama, 35812 11. A. The Radiation Safety Officer (RSO) for this license is Philip 0. Brown. B. Licensed material shall only be used by, or under the supervision of, Philip 0. Brown , Mark J. Christi, and Brian Ramsey. 12. The licensee shall not use the licensed material in or on human beings. 13. The licensee shall not use licensed material in field applications where activity is released except as provided otherwise by spec i fic condition of this license.
NRC 'FORM 374A MATERIALS LICENSE SUPPLEMENTARY SHEET U.S. NUCLEAR REGULATORY COMMISSION License Number 01-06571-10 Amendment No. 55 Docket or Reference Number 030-03575 PAGE 4 OF 6 PAGES 14. A. Sealed sources and detector cells shall be tested for leakage and/or contamination at intervals not to exceed the intervals specified in the certificate of registration issued by the U.S. Nuclear Regulatory Commission under 10 CFR 32.210 or by an Agreement State. In the absence of a registration certificate, sealed sources shall be tested for leakage and/or contamination at intervals not to exceed 6 months, or at such other intervals as specified.
B. Notwithstanding Paragraph A of this Condition , sealed sources designed to primarily emit alpha particles shall be tested for leakage and/or contamina'tion at intervals not to exceed 3 months. C. In the absence of a certificate from a" transferor indicating that a leak test has been made within the intervals specified in the certificate of registration issued by the U.S. Nuclear Regulatory Commission under 10 CFR 32.210 or~by an Agreement State , prior to the transfer, a sealed source received from another person shall not be put into use until tested and the_test results received.
D. Sealed sources need not be tested'if they contain only hydrogen-3; or they contain only a radioactive gas; or the half-life of the isotope is 30 days or less; or they contain not more than 100 microcuries of beta-and/or gamma-emitting material or not more than 10 microcuries of alpha-emitting material.
E. Sealed sources need not be tested if they are in storage and are not being used. Aowever, when they are removed from storage for use ,I or transferred to another person, and have not'been tested within the required leak test interval, they shall be tested before use or transfer. No sealed source shall be stored for a period of more than 10 years without being tested for leakage and/or contamination.
F. The leak test shall be capable of detecting the presence of 185 becquerels (0.005 microcuries) of radioactive material on the test sample. If the test reveals the presence of 185 becquerels (0.005 microcuries) or more of removable contamination, a report shall be filed with the U.S. Nuclear Regulatory Commission in accordance with 10 CFR 30.50(c)(2), and the source shall be removed immediately from service and decontaminated, repaired, or disposed of in accordance with Commission regulations.
G. Tests for leakage and/or contamination, including leak test sample collection and analysis, shall be performed by the licensee or other persons specifically licensed by the U.S. Nuclear Regulatory Commission or an Agreement State to perform such services.
NRC tORM 374A MATERIALS LICENSE SUPPLEMENTARY SHEET U.S. NUCLEAR REGULATORY COMMISSION License Number 01-06571-10 Amendment No. 55 Docket or Reference Number 030-03575 H. Records of leak test results shall be kept in units of becquerels (microcuries) and shall be maintained for 3 years. PAGE 5 OF 6 PAGES 15. Sealed sources or detector cells containing licensed material shall not be-opened or sources removed from source holders by the licensee.
- 16. The licensee shall conduct a physical inventory every 6 months, or at other intervals approved by the U.S. Nuclear Regulatory Commission, to account for all sealed sources and/or devices received and possessed under the license. Records of inventories shall be maintained for 3 years from the date of each inventory, and shall include the radionuclides, quantities, manufacturer's name and model numbers, and the date of the inventory. 17. Maintenance, repair, cleaning, replacement, and disposal of foils contained in detector cells shall be performed only by the device manufacturer or other persons specifically authorized by the U.S. Nuclear Regulatory Commission or an Agreement State to perform such services.
NRC FORM 374A U.S. NUCLEAR REGULATORY COMMISSION PAGE 6 OF 6 PAGES MATERIALS LICENSE SUPPLEMENTARY SHEET License Number 01-06571-10 Amendment No. 55 Docket or Reference Number 030-03575
- 18. Except as specifically provided otherwise in this license, the licensee shall conduct its program in accordance with the statements, representations, and procedures contained in the documents;'including' any enclosures, listed below. This license condition applies only to those procedures that are required to be submitted in~accordance with the regulations.
The U.S. Nuclear Regulatory Commission's regulations shall govern unless the statements,.representations, and procedures in the licensee's application and correspondence are more restrictive than the regulations.
A. Letter dated July 11, 2006 (ML062010457)
B. Letter dated January 14, 2011 (ML 110250591)
C. Letter dated May 8, 2013 (ML 13141A251)
D. Application dated January 27, 2016 (ML 16055A402)
E. Letter received May 26, 2016 (ML 16158A454)
F. Letter dated June 28, 2016 (ML 16250A457)
G. Letter dated June 29, 2017 (ML 17188A 176) , H. Letter dated June 6, 2018 (ML 18169A315)
- FOR THE U.S. NUCLEAR REGULATORY COMMISSION Date: July 11, 2018 By: cJ)~ Dennis Law;:Y Region 1