TO DEEPWELL PUMP MOTOR CONTROLS P 3 I
VENT RECYCLE LINE VENT FROM PLANT WATER WELLS LS i
I LG I
L WELL WATER TANK OVERFLOW OHS T
I WELL WATER BOOSTER PUMPS PS ACTIVATEDCARBON FILTERS PSV
( FILTER BACK-FLUSH TO WASTE ATM yf Y CONCENTRATE REVERSE OSMOSIS PACKAGE UNITS WITH HIGH TO PR ESS UR E PUMPS WASTE LC HYPOCHLORITE MIXINGTEE FC LG SERVICE WATER AND CHLORINE CONTACT TANK LAHL I
LS PSV SERVICE COLD WATER SUPPLY TO UTILITY STATIONS, AIR CONDITIONING
& MISC SERVICES SERVICE HOT WATER SUPPLY SERVICE AIR PSV PC LG ATM HYDROPNEUMATIC TANK I UNIT-11 LC HYPOCHLORITE TANK LG QHS QHS HYPOCHLORITE METERING PUMPS PSV TO DISTRIBUTION SYSTEM TYPICAL FOR EACH UNIT HS I
I I
I SERVICE WATER PUMPS HS 3
TO UNIT I PS TS OTHER SE R VICES SIMILARTO UNIT I DISTRIBUTIONSYS TO UNIT 2 TO UNIT 3 BACKFLOW PREVENTOR TYPICAL SERVICE WATER STORAGE HEATER Arizona Nuclear Power Project 3
Palo Verde Nuclear Generating Station Units 1,2& S I 0407" 7 1 A 2 2 AP 4-4 4 4 Y
Y NOTE:
SYSTEM IS NON NUCLEAR SAFETY BASIC FLOW DIAGRAM SERVICE WATER SYSTEM Figure 9.2-6